Miniature C-Shaped Transducers for Chordae Tendineae Force Measurements

  • Published:
Annals of Biomedical Engineering Aims and scope Submit manuscript

Abstract

C-shaped strain gauge force transducers were designed to enable dynamic measurements of the tension of the individual mitral valve chordae tendineae during the cardiac cycle. The force transducers were constructed from a C-shaped brass ring with a diameter of 6 mm, width of 2 mm, thickness of 0.5 mm, and a mass of <80 mg. Miniature strain gauges elements were cemented onto the inner and outer side of the ring. The strain gauges were connected to thin Teflon® wires and coupled in a Wheatstone half-bridge circuit to a signal conditioner and amplifier. The transducer was coated with a resistive sealing ensuring electrical insulation as well as mechanical protection. Technical testings of sensitivity, linearity, noise level, and frequency response characteristics demonstrated that the transducers were suitable for dynamic chordal force measurements performed under in vitro and in vivo experimental conditions.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

REFERENCES

  1. Lam, H. C., N. Ranganathan, E. D. Wigle, and M. D. Silver. Morphology of the human mitral valve. I. Chordae tendineae: A new classification. Circulation 41: 449–458, 1970.

    Google Scholar 

  2. Lillehei, C.W.,M. J. Levy, and R. C. Bonnabeau, Jr. Mitral valve replacement with preservation of papillary muscles and chordae tendineae. J. Thorac. Cardiovasc. Surg. 47:532–543, 1964.

    Google Scholar 

  3. Lomholt, M., S. L. Nielsen, S. B. Hansen, N. T. Andersen, and J. M. Hasenkam. Differential tension between secondary and primary mitral chordae in an acute in-vivo porcine model. J. Heart Valve Dis. 11:337–345, 2002.

    Google Scholar 

  4. Millington-Sanders, C., A. Meir, L. Lawrence, and C. Stolinski. Structure of chordae tendineae in the left ventricle of the human heart. J. Anat. 192(Pt 4):573–581, 1998.

    Article  Google Scholar 

  5. Nichols, W. W., and M. F. O'Rourke. The nature of flow of a fluid. In: McDonald's Blood Flow in Arteries. Theoretical, Experimental and Clinical Principles, edited by W. W. Nichols and M. F. O'Rorke. Philidelphia: Lea & Febiger, 1990, pp. 12–53.

    Google Scholar 

  6. Nielsen, S. L., H. Nygaard, A. A. Fontaine, J. M. Hasenkam, S. He, N. T. Andersen, and A. P. Yoganathan. Chordal force distribution determines systolic mitral leaflet configuration and severity of functional mitral regurgitation. J. Am. Coll. Cardiol. 33:843–853, 1999.

    Article  Google Scholar 

  7. Nielsen, S. L., T. A. Timek, G. R. Green, P. Dagum, G. T. Daughters, J. M. Hosenkam, A. F. Bolger, N. B. Ingels, and D. C. Miller. Influence of anterior mitral leaflet second-order chordae tendineae on left ventricular systolic function. Circulation 108:486–491, 2003.

    Article  Google Scholar 

  8. Nielsen, S. L., T. A. Timek, D. T. Lai, et al.Edge-to-edge mitral repair: Tension on the approximating suture and leaflet deformation during acute ischemic mitral regurgitation in the ovine heart. Circulation 104:I29–I35, 2001.

    Google Scholar 

  9. Salisbury, P. F., C. E. Cross, and P. A. Rieben. Chorda tendinea tension. Am. J. Physiol. 205: 385–392, 1963.

    Google Scholar 

  10. Sarris, G. E., and D. C. Miller. Valvular-ventricular interaction: The importance of the mitral chordae tendineae in terms of global left ventricular systolic function. J. Card Surg. 3: 215–234, 1988.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Nielsen, S.L., Soerensen, D.D., Libergren, P. et al. Miniature C-Shaped Transducers for Chordae Tendineae Force Measurements. Annals of Biomedical Engineering 32, 1050–1057 (2004). https://doi.org/10.1114/B:ABME.0000036641.69903.62

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1114/B:ABME.0000036641.69903.62

Navigation