Skip to main content
Log in

A Spherical Rotation Coordinate System for the Description of Three-Dimensional Joint Rotations

  • Published:
Annals of Biomedical Engineering Aims and scope Submit manuscript

Abstract

Three-dimensional joint rotations in human movement analysis have been mainly described by Euler/Cardan angles. Due to sequence dependence, each combination of three Euler/Cardan angles defines a single pattern of joint rotation. When the rotation pattern is unknown, it needs to be considered using a particular sequence of Euler/Cardan angles to represent joint rotations. In this paper a spherical rotation coordinate system is developed for describing three-dimensional joint rotations using a method of rotation involving two steps: a long axis rotation and a pure axial rotation. Two angles of the classical spherical coordinate system—longitude and latitude—are used to describe long axis rotations in this newly proposed coordinate system. The spherical rotation coordinate system uses a radial rotation angle to describe pure axial rotation of a limb segment whereas the classical spherical coordinate system uses a radial displacement to describe motion of a point. An application of the spherical rotation coordinate system is given to define three-dimensional rotations of the glenohumeral joint. A mathematical proof shows that the long axis rotation and axial rotation are sequence independent. Two numerical examples are investigated which demonstrate that the spherical rotation angles can be uniquely determined in both forward and inverse kinematics without considering sequences of rotations. © 2000 Biomedical Engineering Society.

PAC00: 8719St

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

REFERENCES

  • 1An, K.-N., A. O. Browne, S. Korinek, S. Tanaka, and B. F. Morrey. Three-dimensional kinematics of glenohumeral elevation. Orthop. Res. 9:143-149, 1991.

    Google Scholar 

  • 2Chao, E. Y. S. Justification of triaxial goniometer for the measurement of joint rotation. J. Biomech. 13:989-1006, 1980.

    Google Scholar 

  • 3Cheng, P. L., A. C. Nicol, and J. P. Paul. Determination of axial rotation angles of limb segments-a new method. J. Biomech. 33:837-843, 2000.

    Google Scholar 

  • 4Cole, G. K., B. M. Nigg, J. L. Ronsky, and M. R. Yeadon. Application of the joint coordinate system to three-dimensional joint attitude and movement representation: A standardization proposal. J. Biomech. Eng. 115:334-349, 1993.

    Google Scholar 

  • 5Craig, J. J. Introduction to Robotics: Mechanics and Control, 2nd ed. Reading, MA: Addison-Wesley, 1986.

    Google Scholar 

  • 6Goldstein, H. Classical Dynamics. New York: Addison-Wesley, 1960.

    Google Scholar 

  • 7Grood, E. S., and W. J. Suntay. A joint coordinate system for clinical description of three-dimensional motions: application to the knee. J. Biomech. Eng. 105:136-144, 1983.

    Google Scholar 

  • 8Haslwanter, T. Mathematics of three-dimensional eye rotations. Vision Res. 35:1727-1739, 1995.

    Google Scholar 

  • 9Haustein, W. Considerations on Listing's law and the primary position by means of matrix description of eye position control. Biol. Cybern. 60:411-420, 1989.

    Google Scholar 

  • 10Kapandji, I. A. The Physiology of the Joint. Edinburgh: Churchill Livingston, 1970.

    Google Scholar 

  • 11Kinzel, G. L., A. S. Hall, Jr., and B. M. Hillberry. Measurement of total motion between two body segments-I. Analytical development. J. Biomech. 5:93-105, 1972.

    Google Scholar 

  • 12Nigg, B. M., and W. Herzog. Biomechanics of the Musculoskeletal System, 2nd ed. New York: Wiley, 1999.

    Google Scholar 

  • 13Roberson, R. E., and R. Schwertassek. Dynamics of Multi-body System. Berlin: Springer, 1988.

    Google Scholar 

  • 14Tupling, S. J., and M. R. Pierrynowski. Use of Cardan angles to locate rigid bodies in three-dimensional space. Med. Biol. Eng. Comput. 25:527-532, 1987.

    Google Scholar 

  • 15Woltring, H. 3-D attitude representation of human joints: a standardization proposal. J. Biomech. 27:1399-1414, 1994.

    Google Scholar 

  • 16Wu, G., and P. R. Cavanagh. ISB recommendations for standardization in the reporting of kinematic data. J. Biomech. 28:1257-1261, 1995.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Cheng, P.L. A Spherical Rotation Coordinate System for the Description of Three-Dimensional Joint Rotations. Annals of Biomedical Engineering 28, 1381–1392 (2000). https://doi.org/10.1114/1.1326030

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1114/1.1326030

Navigation