Conclusions

In this study an experimental test set-up has been developed for evaluation of the fixation of glenoid components to be used in a Total Shoulder Replacement. Using force controlled upper arm motion compared to displacement controlled motion will give better insight into the effect of geometrical design parameters of the glenoid component. By using custom made displacement sensors, the structural deformation can be measured, indicating the future fixation performance of the glenoid component.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Wirth, M., Rockwood, C., “Complications of Shoulder Arthroplasty,” J Bone Joint Surg Am 8(4), 603–61 (1996).

    Article  Google Scholar 

  2. Hasan, S.S., Leith, J.M., Campbell, B., Kapil, R., Smith, K.L., Matsen, F.A. 3rd. “Characteristics of Unsatisfactory Shoulder Arthroplasties,” J Shoulder Elbow Surg Sep–Oct; 11(5):431–41 (2002).

    Article  Google Scholar 

  3. Radler, C., Wozasek, G.E., Seitz, H., Vecsei, V. “Distal Femoral Fracture through the Screw Hole of a Ligament Augmentation Device Fixation,” Arthroscopy Oct; 16(7):737–9 (2000).

    Article  Google Scholar 

  4. Collins, D., Tencer, A., Sidles, J., Matsen, F. 3rd. “Edge Displacement and Deformation of Glenoid Components in Response to Eccentric Loading. The Effect of Preparation of the Glenoid Bone,” J Bone Joint Surg Am, Apr; 74(4):501–7 (1992).

    Article  Google Scholar 

  5. Fukuda, K., Chen, C.M., Cofield, R.H., Chao, E.Y. “Biomechanical Analysis of Stability and Fixation Strength of Total Shoulder Prostheses,” Orthopedics Jan; 11(1):141–9 (1988).

    Google Scholar 

  6. Karduna, A.R., Williams, G.R., Iannotti, J.P., Williams, J.L., “Total Shoulder Arthroplasty Biomechanics: a Study of the Forces and Strains at the Glenoid Component,” J Biomech Eng. Feb; 120(1):92–9 (1998).

    Article  Google Scholar 

  7. Severt, R., Thomas, B.J., Tsenter, M.J., Amstutz, H.C., Kabo. J.M. “The Influence of Conformity and Constraint on Translational Forces and Frictional Torque in Total Shoulder Arthroplasty,” Clin Orthop. Jul; (292):151–8 (1993).

    Google Scholar 

  8. Anglin, C., Wyss, U.P., Pichora, D.R. “Shoulder Prosthesis Subluxation: Theory and Experiment,” J Shoulder Elbow Surg; 9, 104–114 (2000).

    Article  Google Scholar 

  9. Anglin, C., Wyss, U.P., Nyffeler, R.W., Gerber, C. “Loosening Performance of Cemented Glenoid Prosthesis Design Pairs,” Clin Biomech (Bristol, Avon). Feb; 16(2):144–50 (2001).

    Article  Google Scholar 

  10. Oosterom, R., Herder, J.L., van der Helm, F.C.T. Świȩszkowski, W., and Bersee, H.E.N., “Translational Stiffness of the Replaced Shoulder Joint,” J Biomech. Dec; 36(12):1897–1907 (2003).

    Article  Google Scholar 

  11. Prescher, A. “Anatomical Basics, Variations, and Degenerative Changes of the Shoulder Joint and Shoulder Girdle,” Eur J Radiol. Aug; 35(2):88–102 (2000).

    Article  Google Scholar 

  12. van der Helm, F.C.T. “Analysis of the Kinematic and Dynamic Behavior of the Shoulder Mechanism,” J Biomech. May; 27(5):527–50 (1994).

    Article  Google Scholar 

  13. Bicknell, R.T., Liew, A.S., Danter, M.R., Patterson, S.D., King, G.J., Chess, D.G., Johnson, J.A. “Does Keel Size, the Use of Screws, and the Use of Bone Cement Affect Fixation of a Metal Glenoid Implant,” J Shoulder Elbow Surg. May–Jun; 12(3):268–75 (2003).

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Oosterom, R., Bersee, H. Force controlled fatigue testing of shoulder prostheses. Exp Tech 28, 33–37 (2004). https://doi.org/10.1111/j.1747-1567.2004.tb00184.x

Download citation

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1111/j.1747-1567.2004.tb00184.x

Navigation