Abstract
Multiphase flow in permeable media is a complex pore-scale phenomenon, which is important in many natural and industrial processes. To understand the pore-scale dynamics of multiphase flow, we acquired time-series synchrotron X-ray micro-tomographic data at a voxel-resolution of 3.28 μm and time-resolution of 38 s during drainage and imbibition in a carbonate rock, under a capillary-dominated flow regime at elevated pressure. The time-series data library contains 496 tomographic images (gray-scale and segmented) for the complete drainage process, and 416 tomographic images (gray-scale and segmented) for the complete imbibition process. These datasets have been uploaded on the publicly accessible British Geological Survey repository, with the objective that the time-series information can be used by other groups to validate pore-scale displacement models such as direct simulations, pore-network and neural network models, as well as to investigate flow mechanisms related to the displacement and trapping of the non-wetting phase in the pore space. These datasets can also be used for improving segmentation algorithms for tomographic data with limited projections.
Design Type(s) | image analysis objective • time series design • image processing objective |
Measurement Type(s) | fluid flow rate |
Technology Type(s) | micro-computed tomography |
Factor Type(s) | fluid • experimental stage |
Sample Characteristic(s) | sedimentary rock |
Machine-accessible metadata file describing the reported data (ISA-Tab format)
Similar content being viewed by others
Background & Summary
Understanding the dynamics of multiphase fluid flow in permeable media is important in many processes such as water infiltration in soils, oil recovery from reservoir rocks, geo-sequestration of supercritical CO2 to address global climate change, and subsurface non-aqueous phase liquid contaminant transport1–6. These processes have been studied for decades in two dimensions using micro-models and microfluidic devices7–11, which do not provide a complete picture of the dynamics of multiphase flow in a complex realistic permeable medium. In three dimensions, previous studies have used lab-based X-ray micro-tomography to visualize immiscible fluids in porous media at end states12–16, i.e., before and after fluid injection, which provide detailed information on the static distribution of fluids but do not describe the dynamics of their transport mechanisms. Time-resolved imaging in lab-based instruments is restricted due to a low photon flux, which results in a time resolution of the order of hours. To obtain a higher photon flux, several studies have used synchrotron X-ray imaging to investigate drainage (displacement of a wetting fluid by a non-wetting fluid) and imbibition (displacement of a non-wetting by a wetting fluid) processes in glass beads and natural porous media (carbonates and sandstones)4,5,17–24.
We conducted a high-resolution fast synchrotron X-ray micro-tomographic imaging study of the displacement of immiscible fluids during drainage and imbibition in a carbonate rock sample under a capillary-controlled flow regime at elevated pressure conditions22. The dynamic flow displacement experiments were conducted in a 3.8 mm diameter and 10 mm long Ketton limestone sample. The sample was first saturated with brine. The system was then pressurized to 10 MPa, followed by injection of oil (a drainage process for water-wet porous media) from the top of the sample by establishing a pressure gradient of 50 kPa across the sample. When there was no longer any visible change in the oil and brine saturation, the flow was reversed by raising the pressure in the brine pump and establishing a pressure gradient of 22 kPa to start brine injection (an imbibition process for a water-wet porous medium) from the base of the sample. The sample was imaged continuously during drainage and imbibition, with a voxel size of 3.28 μm and acquisition speed of 38 s for each image.
A complete three-dimensional time-resolved image sequence of drainage and imbibition is available online (Data Citation 1 and Data Citation 2). The residual oil at the end of imbibition contains a number of disconnected oil ganglia, these images are also available online (Data Citation 3). These datasets were collected with the aim of investigating pore-scale processes during immiscible fluid displacement under a capillary-dominated flow regime22. The time-dependent information can be used to validate models of pore-scale displacement, such as direct simulations25–27, pore-network27,28 and neural network models29–31. Furthermore, the data can be used to quantify how the balance of viscous and capillary forces control the exact nature of trapping, and to further analyze the complex pore-scale processes during immiscible fluid flow in permeable media. In addition, these datasets can be used for improving segmentation algorithms for tomographic data with limited projections.
The time-resolved synchrotron X-ray micro-tomographic images are hosted at the British Geological Survey (BGS) repository, the details of which are provided in the Data Records and Data Citations sections.
Methods
In this section, we first provide the details of our experimental protocol, followed by synchrotron imaging and image processing. These descriptions overlap with the experimental details provided in Singh, et al.22.
Experimental methodology
The experiments were conducted in a Hassler-type flow cell made of carbon fiber that is nearly transparent to X-rays14. A 3.8 mm diameter and 10 mm long cylindrical sample of the Ketton limestone rock (from the Ketton quarry, Rutland, UK, which contains >99% calcite with the remaining fraction being quartz14,32), which was cleaned with methanol using a Soxhlet extraction apparatus for 24 h followed by drying in a vacuum oven at 100 °C for 24 h, was placed on the top of a low-permeability water-wet Aluminum-silicate ceramic porous plate (3.8 mm diameter and ~ 4 mm long) with a breakthrough pressure of 1.5 MPa (Weatherford Laboratories, Stavanger, Norway) in a Viton sleeve. The Viton sleeve was attached to a metal end piece at the base, which was connected to a high-pressure syringe pump (ISCO-100D, TELEDYNE, U.S.A.) with PEEK tubing (Kinesis, U.K.). A PEEK spacer, with an outer and inner diameter of 4 mm and 2 mm respectively, was placed on the top of the sample, which allowed monitoring of the brine-oil interface while the system was pressurized and prior to oil injection in the water saturated sample. The rock was imaged before starting oil and brine injection (hereafter called the dry reference scan).
The flow loop of the experimental apparatus is shown in Singh, et al.22. After acquiring a dry reference scan, CO2 was injected in the sample to displace air. The brine (1.8 M solution of potassium iodide, puriss, 99.5%, Sigma-Aldrich, U.K.) was injected through the sample from the base at 0.1-0.2 mL/min. A total of 80-100 pore volumes of brine was injected to remove both gaseous and dissolved CO2 in brine, ensuring 100% brine saturation. This concentration of the salt solution was pre-selected to obtain an effective X-ray contrast between brine and oil.
The oil (decane, ReagentPlus, ≥ 99%, Sigma-Aldrich, U.K.) was filtered four times through a column of aluminum oxide powder to remove surface active impurities and to obtain a stable brine-oil interfacial tension33. The oil was then loaded into the pump and pushed through the flow lines to the upper metal end piece. The metal end piece was then carefully attached to the upper part of the Viton sleeve (on the top of the brine-filled PEEK spacer), avoiding air entrapment during assembly. In this way, the brine-oil interface was established near the top of the PEEK spacer. The core holder was then mounted on the rotation stage of the beamline. The sample was aligned to the X-ray beam. The pressure in the brine, oil and the confining fluid (deionized water) was then raised step-wise to 10 MPa and 11.2 MPa respectively. A higher confining pressure was used to confine the Viton sleeve in which the sample was placed, to avoid any fluid bypassing along the walls of the sample. The brine-oil interface in the PEEK spacer was carefully monitored during pressurizing the fluids. All the pumps were previously calibrated and tested for pressure difference by interconnecting and pressuring them. All the experiments were conducted at ambient temperature (20 °C).
For oil flooding, the pressure of the oil pump was raised by 50 kPa, which resulted in the migration of water-oil interface from the top of the sample. The water-wet porous plate prevented the non-wetting phase (oil) to pass through at the pressure drop used in this experiment, therefore, removing the dead volume during brine flooding as the oil-brine interface was established just at the base of the core sample after drainage. The sample was continuously imaged during drainage. When there was no visible change in the oil and brine phases (found by subtracting the projection data of consecutive tomographic images), the flow was reversed by raising the pressure in the brine pump and establishing a pressure gradient of 22 kPa to start brine injection from the base of the sample. The low-permeability porous plate at the base of the core sample provided low flow rates, which was important to acquire distortion free time-resolved tomographic images. A flow rate of 44.75 nL/min was achieved during imbibition, leading to a Darcy velocity of 3.94 μm/min and a capillary number (Nc = νμ/γ, where ν is the Darcy velocity of the invading fluid, μ is the viscosity of the invading fluid, and γ is the brine-oil interfacial tension) of 1.26 × 10−9, using an interfacial tension of 52.33 ± 0.04 mN/m34), representing a capillary-flow regime. The sample was continuously imaged during imbibition.
Synchrotron imaging and image processing
The time-resolved X-ray micro-tomography was performed at the Diamond Light Source (UK), Beamline I13, using a pink beam with energies in the range of 6 to 30 keV. The low energy X-rays were filtered by placing a set of 0.2 mm pyrolitic graphite, 2.2 mm aluminum, and 0.1 mm gold filters in the beam. This reduced the relative intensity of low-energy X-ray in the polychromatic X-ray spectrum, controlling sample heating. The sample was rotated by 180° during the acquisition of the projection data. It was then brought back to the initial position for the next tomographic image. The X-rays that passed through the sample were converted to visible light by a 250 μm thick CdWO4 scintillator; which was then recorded by a PCO Edge camera with 2 × objective.
Tomographic images with a size of 20003 voxels were acquired at a voxel size of 1.64 μm, which were then binned (2 × 2 × 2) to obtain images of 10003 voxels with a voxel size of 3.28 μm. The binning was used to decrease the size of the final image. The binning also helped improve the signal-to-noise ratio. A total of 3000 projections with an exposure time of 0.06 s was acquired over 180° rotation for the dry reference scan of the sample (without any fluids). For time-resolved imaging during drainage and imbibition, we collected 800 projections with an exposure time of 0.02 s for each tomographic image. The total acquisition time for each time-resolved tomographic image was 24 s (16 s for acquisition and 8 s for triggering). The real time-step between each image was 38 s. This also included 14 s for repositioning the rotation stage to its initial position and transferring the data to a storage disk. During the complete drainage and imbibition processes, we acquired a total of 496 and 416 tomographic images respectively. The images were reconstructed using a filtered back-projection algorithm35. A cylindrical mask equivalent to the diameter of the rock sample was applied on the reconstructed data to remove unwanted regions including the Viton sleeve, followed by its conversion from 32-bit to 16-bit to reduce the size, using ImageJ software (https://imagej.net). Hereafter, all the image-processing steps were performed using Avizo-9 software (https://www.fei.com/software/amira-avizo/).
First, the dry reference scan (Fig. 1a) was filtered with a non-local means edge preserving filter36,37 (Fig. 1b) (Data Citation 4). Figure 1c shows the intensity profiles of the original raw and filtered images. Clearly, the filtering process enhances the contrast between air and rock, indicated by two separate peaks in the filtered image. We also compared the interphase signal-to-noise ratio (ISNR) of the original and filtered images. The ISNR was obtained by calculating the means, mr and mp, and standard deviation, σr and σp, of the gray-scale values within the rock and the pore space38.
The value of the ISNR increased from 2.8 (for the original image) to 8.8 (for the filtered image), indicating a significant enhancement of signal (or reduction of noise) in the image.
The filtered dry reference scan was then segmented (binarized) into two phases (pore and solid) with a seeded watershed algorithm based on the gray-scale gradient and gray-scale intensity of each voxel39 (Fig. 1d) (Data Citation 4). Here, the rock and pore space are shown in gray and black respectively. All the filtered time-series images were then registered to the filtered dry reference scan using normalized mutual information and resampled onto the same voxel grid as the dry reference scan. Each time-series filtered tomographic image containing three phases (Fig. 1e) (Data Citation 4) was then subtracted from the brine-saturated image (Fig. 1f) (Data Citation 4). The image subtraction not only helped in enhancing the contrast between oil and the other phases, but also canceled out the effect of phase-contrast represented by dark spots in the images (e.g., Fig. 1f). These subtracted images were then again filtered using a non-local means filter to increase the signal-to-noise ratio (Fig. 1g). The filtered images were segmented for the oil phase using intensity-based thresholding (Fig. 1h) (Data Citation 4). Figure 1i shows the segmented oil superimposed on the three-phase filtered image (Fig. 1e), which shows the effective segmentation based on the subtracted images. The quality of non-local means filtering and segmentation was also inspected at the pore scale. Figure 1j shows a zoomed-in image of the original raw scan containing three phases. Figure 1k shows the same location after applying non-local means filter, indicating that the filtering improves the signal-to-noise ratio significantly while keeping the phase boundaries preserved. Figure 1l shows the segmented oil superimposed on the filtered image (Fig. 1k), which indicates that segmentation process based on subtracted images captured the oil phase boundary effectively. The oil-segmented datasets were used by Singh, et al.22 for curvature and capillary pressure analysis during oil snap-off at the pore scale. The three-phase segmented image can be obtained by combining the segmented oil image (Fig. 1h) and the segmented dry reference scan (Fig. 1d).
Data Records
The data for this manuscript are available on the British Geological Survey (BGS) repository (Data Citation 4), which comprises a dry scan of the rock sample without fluids (unfiltered gray-scale, filtered gray-scale and segmented images), a scan of the rock saturated with brine (unfiltered and filtered gray-scale images), 496 time-series tomographic images of drainage (unfiltered gray-scale, filtered gray-scale and segmented images), and 416 time-series tomographic images of imbibition (unfiltered gray-scale, filtered gray-scale and segmented images). Table 1 shows the details of the tomographic images. It should be noted that the datasets (i) Drainage_time_series_unfiltered, (ii) Drainage_time_series_filtered, (iii) Imbibition_time_series_unfiltered, and (iv) Imbibition_time_series_filtered are not available for downloading from the BGS repository due to their large file sizes. These datasets can be obtained by sending a request to the BGS. Further details are provided in the section Access the dataset (file name: Accessing Data.docx) in Data Citation 4. The rest of the datasets are available for downloading.
Table 2 shows the phase information. Table 3 and Table 4 show the time-step between consecutive time-series tomographic images for drainage and imbibition respectively. In general, images were acquired with a time-step of 38 s. However, the acquisition during imbibition was stopped after scan number 58, 307, 350 and 378 (Table 4) due to failure of the camera control software. Note that the brine injection was not interrupted during rebooting of the camera software. When there was no significant change in oil saturation, we acquired images with a time-step of 950 s (after scan 410 in Table 4) except for the last scan which was acquired with a time-step of 722 s (Table 4).
Technical Validation
The detector at the beamline I13 (Diamond Light Source) was focused with a high precision 1 mm thick knife edge (JJ X-ray). Multiple images of the knife edge were acquired at different focusing distances, using a PCO Edge camera with a 2 × objective, which were then corrected for dark and flat fields. Figure 2 shows line profiles across the edge of the knife for different focusing distances. Focusing was tuned in steps of 0.05 mm (only larger steps of 0.35 mm are shown in Fig. 2), until a sharp interface was obtained (Fig. 2g corresponding to data 6 in Fig. 2a).
The sample rotation stage was aligned perpendicular to the X-ray beam (pitch alignment) and the rows of the detector within an angular precision of 200 μrad. The axial run-out of the rotation stage is 50 nm and the angular tilt is 0.1 μrad.
Usage Notes
The tomographic data can be loaded as .raw files using an open source software ‘ImageJ’ (http://imagej.nih.gov/ij). ImageJ has many available plugins for image processing and analysis. For the details of using Imagej for cropping, resizing, adjusting brightness/contrast, readers are referred to Rowe, et al.40. For three-dimensional visualization, the data can be loaded on an open source software ‘Drishti’ (https://github.com/nci/drishti/wiki).
The data can also be loaded and processed on a commercial software ‘Avizo’ (https://www.fei.com/software/amira-avizo/), which is a powerful tool for data processing, segmentation and analysis. It also has an option of loading and visualizing the complete time-series data. The datasets can also be loaded to any other commercial image processing software.
Additional information
How to cite this article: Singh, K. et al. Time-resolved synchrotron X-ray micro-tomography datasets of drainage and imbibition in carbonate rocks. Sci. Data. 5:180265 doi: 10.1038/sdata.2018.265 (2018).
Publisher’s note: Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
References
References
Honeyman, B. D. Geochemistry: Colloidal culprits in contamination. Nature 397, 23–24 (1999).
Shaffer, G. Long-term effectiveness and consequences of carbon dioxide sequestration. Nature Geoscience 3, 464–467 (2010).
Morrow, N. & Buckley, J. Improved oil recovery by low-salinity waterflooding. Journal of Petroleum Technology 65, 106–112 (2011).
Andrew, M., Menke, H., Blunt, M. & Bijeljic, B. The imaging of dynamic multiphase fluid flow using synchrotron-based X-ray microtomography at reservoir conditions. Transport in Porous Media 110, 1–24 (2015).
Berg, S. et al. Real-time 3D imaging of Haines jumps in porous media flow. Proceedings of the National Academy of Sciences 110, 3755–3759 (2013).
Blunt, M. J. Multiphase Flow In Permeable Media: A Pore-Scale Perspective, Cambridge University Press (2017).
Lenormand, R. & Zarcone, C. Role of roughness and edges during imbibition in square capillaries. In SPE Annual Technical Conference and Exhibition, SPE 13264 (1984).
Lenormand, R., Zarcone, C. & Sarr, A. Mechanisms of the displacement of one fluid by another in a network of capillary ducts. Journal of Fluid Mechanics 135, 337–353 (1983).
Jung, M. et al. Wettability controls slow immiscible displacement through local interfacial instabilities. Physical Review Fluids 1, 074202 (2016).
Zhao, B., MacMinn, C. W. & Juanes, R. Wettability control on multiphase flow in patterned microfluidics. Proceedings of the National Academy of Sciences 113, 10251–10256 (2016).
Niven, R. K. & Singh, K. Mobilization and rupture of LNAPL ganglia during freeze-thaw: two-dimensional cell experiments. Environmental Science & Technology 42, 5467–5472 (2008).
Singh, K., Bijeljic, B. & Blunt, M. J. Imaging of oil layers, curvature and contact angle in a mixed-wet and a water-wet carbonate rock. Water Resources Research 52, 1716–1728 (2016).
Pak, T., Butler, I. B., Geiger, S., van Dijke, M. I. J. & Sorbie, K. S. Droplet fragmentation: 3D imaging of a previously unidentified pore-scale process during multiphase flow in porous media. Proceedings of the National Academy of Sciences 112, 1947–1952 (2015).
Andrew, M., Bijeljic, B. & Blunt, M. J. Pore-scale imaging of trapped supercritical carbon dioxide in sandstones and carbonates. International Journal of Greenhouse Gas Control 22, 1–14 (2014).
Kumar, M., Knackstedt, M. A., Senden, T. J., Sheppard, A. P. & Middleton, J. P. Visualizing and quantifying the residual phase distribution in core material. Petrophysics 51, 323–332 (2010).
Singh, K. et al. Remobilization of residual non-aqueous phase liquid in porous media by freeze−thaw cycles. Environmental Science & Technology 45, 3473–3478 (2011).
Reynolds, C. A., Menke, H., Andrew, M., Blunt, M. J. & Krevor, S. Dynamic fluid connectivity during steady-state multiphase flow in a sandstone. Proceedings of the National Academy of Sciences (2017).
Rücker, M. et al. From connected pathway flow to ganglion dynamics. Geophysical Research Letters 42, 3888–3894 (2015).
Armstrong, R. T., Georgiadis, A., Ott, H., Klemin, D. & Berg, S. Critical capillary number: Desaturation studied with fast X-ray computed microtomography. Geophysical Research Letters 41, 55–60 (2014).
Schlüter, S. et al. Pore-scale displacement mechanisms as a source of hysteresis for two-phase flow in porous media. Water Resources Research 52, 2194–2205 (2016).
Singh, K. et al. The role of local instabilities in fluid invasion into permeable media. Scientific Reports 7, 444 (2017).
Singh, K. et al. Dynamics of snap-off and pore-filling events during two-phase fluid flow in permeable media. Scientific Reports 7, 5192 (2017).
Berg, S. et al. Onset of oil mobilization and nonwetting-phase cluster-size distribution (2015).
Schlüter, S., Berg, S., Li, T., Vogel, H.-J. & Wildenschild, D. Time scales of relaxation dynamics during transient conditions in two-phase flow. Water Resources Research 53, 4709–4724 (2017).
Raeini, A. Q., Bijeljic, B. & Blunt, M. J. Modelling capillary trapping using finite-volume simulation of two-phase flow directly on micro-CT images. Advances in Water Resources 83, 102–110 (2015).
Raeini, A. Q., Blunt, M. J. & Bijeljic, B. Direct simulations of two-phase flow on micro-CT images of porous media and upscaling of pore-scale forces. Advances in Water Resources 74, 116–126 (2014).
Raeini, A. Q., Bijeljic, B. & Blunt, M. J. Generalized network modeling: Network extraction as a coarse-scale discretization of the void space of porous media. Physical Review E 96, 013312 (2017).
Bultreys, T. et al. Validation of model predictions of pore-scale fluid distributions during two-phase flow. Physical Review E 97, 053104 (2018).
Das, D. B., Thirakulchaya, T., Deka, L. & Hanspal, N. S. Artificial Neural Network to Determine Dynamic Effect in Capillary Pressure Relationship for Two-Phase Flow in Porous Media with Micro-Heterogeneities. Environmental Processes 2, 1–18 (2015).
Hanspal, N. S., Allison, B. A., Deka, L. & Das, D. B. Artificial neural network (ANN) modeling of dynamic effects on two-phase flow in homogenous porous media. Journal of Hydroinformatics 15, 540–554 (2013).
Abidoye, L. K. & Das, D. B. Artificial neural network modeling of scale-dependent dynamic capillary pressure effects in two-phase flow in porous media. Journal of Hydroinformatics 17, 446–461 (2015).
Andrew, M., Bijeljic, B. & Blunt, M. J. Pore-by-pore capillary pressure measurements using X-ray microtomography at reservoir conditions: Curvature, snap-off, and remobilization of residual CO2 . Water Resources Research 50, 8760–8774 (2014).
Goebel, A. & Lunkenheimer, K. Interfacial tension of water/n-alkane interface. Langmuir 13, 369–372 (1997).
Zeppieri, S., Rodríguez, J. & López de Ramos, A. L. Interfacial tension of alkane+water systems. Journal of Chemical & Engineering Data 46, 1086–1088 (2001).
Kyrieleis, A., Titarenko, V., Ibison, M., Connolley, T. & Withers, P. J. Region-of-interest tomography using filtered backprojection: assessing the practical limits. Journal of Microscopy 241, 69–82 (2011).
Buades, A., Coll, B. & Morel, J.-M. Nonlocal image and movie denoising. International Journal of Computer Vision 76, 123–139 (2008).
Buades, A., Coll, B. & Morel, J. M. A non-local algorithm for image denoising. In IEEE Computer Society Conference on Computer Vision and Pattern Recognition 60–65 (2005).
Andrew, M. Reservoir Condition Pore Scale Imaging of Multiphase Flow using X-Ray Microtomography. Imperial College London, (2015).
Jones, A. C. et al. Assessment of bone ingrowth into porous biomaterials using MICRO-CT. Biomaterials 28, 2491–2504 (2007).
Rowe, T. B., Luo, Z.-X., Ketcham, R. A., Maisano, J. A. & Colbert, M. W. X-ray computed tomography datasets for forensic analysis of vertebrate fossils. Scientific Data 3, 160040 (2016).
Data Citations
Singh, K. Figshare https://doi.org/10.6084/m9.figshare.7082885.v1 (2018)
Singh, K. Figshare https://doi.org/10.6084/m9.figshare.7082900.v1 (2018)
Singh, K. Figshare https://doi.org/10.6084/m9.figshare.4232324.v1 (2017)
Singh, K., & Blunt, M. J. British Geological Survey https://doi.org/10.5285/3aa44060-d4fd-453f-9e5b-7d885ad5089f (2018)
Acknowledgements
We gratefully acknowledge funding from the Qatar Carbonates and Carbon Storage Research Centre (QCCSRC), provided jointly by Qatar Petroleum, Shell, and Qatar Science & Technology Park. K.S. gratefully acknowledges Tarik Saif, Yousef Al-Khulaifi, Norman Nicholls, Qingyang Lin, Dr. Joan Vila-Comamala, Kaz Wanelik, and Shashidhara Marathe for help in imaging and processing, and Iain Macdonald, Terrence Crombie, Nele Wenck and Mary R. Mowat for help in data uploading on the BGS repository. We thank Diamond Light Source for access to beamline I13 (MT11587).
Author information
Authors and Affiliations
Contributions
K.S. and M.J.B. designed the research work. K.S., H.M. and M.A. constructed the experimental apparatus. K.S., H.M. and M.A., C.R. and B.B. conducted the experiments. K.S. conducted data processing. K.S. and M.J.B. wrote the manuscript with input from all other authors.
Corresponding author
Ethics declarations
Competing interests
The authors declare no competing interests.
ISA-Tab metadata
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/ The Creative Commons Public Domain Dedication waiver http://creativecommons.org/publicdomain/zero/1.0/ applies to the metadata files made available in this article.
About this article
Cite this article
Singh, K., Menke, H., Andrew, M. et al. Time-resolved synchrotron X-ray micro-tomography datasets of drainage and imbibition in carbonate rocks. Sci Data 5, 180265 (2018). https://doi.org/10.1038/sdata.2018.265
Received:
Accepted:
Published:
DOI: https://doi.org/10.1038/sdata.2018.265
- Springer Nature Limited
This article is cited by
-
Terahertz imaging for non-destructive porosity measurements of carbonate rocks
Scientific Reports (2022)
-
Direct Numerical Simulation of Pore-Scale Trapping Events During Capillary-Dominated Two-Phase Flow in Porous Media
Transport in Porous Media (2021)
-
A cone-beam X-ray computed tomography data collection designed for machine learning
Scientific Data (2019)