Abstract
Cellular therapies based on human pluripotent stem cells (hPSCs) offer considerable promise for treating numerous diseases including diabetes and end stage liver failure. Stem cell spheroids may be cultured in stirred bioreactors to scale up cell production to cell numbers relevant for use in humans. Despite significant progress in bioreactor culture of stem cells, areas for improvement remain. In this study, we demonstrate that microfluidic encapsulation of hPSCs and formation of spheroids. A co-axial droplet microfluidic device was used to fabricate 400 μm diameter capsules with a poly(ethylene glycol) hydrogel shell and an aqueous core. Spheroid formation was demonstrated for three hPSC lines to highlight broad utility of this encapsulation technology. In-capsule differentiation of stem cell spheroids into pancreatic β-cells in suspension culture was also demonstrated.
Similar content being viewed by others
Introduction
There is considerable interest in spheroid cultures of human pluripotent stem cells (hPSCs). This interest is driven in part by the emerging notion that 3D or spheroid cultures are more physiological and better recapitulate signaling present in vivo1,2. For example, embryoid bodies, three-dimensional aggregate of cells in early developmental stages, improve differentiation to mature cell types. More recently, the use of spheroids of pluripotent cells has gained popularity for expansion of hPSCs because the 3D cell clusters recapitulate dimensions and gradients of signals present in an early stage embryo3.
Another driver for the emergence of spheroid cultures of hPSCs is the need to scale-up. Clinical applications of cellular therapies are likely to require millions to billions of cells (depending on the application)—numbers that are difficult to achieve using standard 2D cultures systems where cell number is proportional to the adherent area. In contrast, scale-up is more feasible in suspension cultures where the number of cells is proportional to the volume of the culture system. As a result, suspension cultures have gained popularity as the method of choice for scalable expansion4,5,6 and differentiation7,8 of hPSCs. Given the importance of embryoid body-like geometry for proliferation and differentiation of hPSCs, these cells have typically been formed into spheroids for suspension culture2. Spheroid formation in standard suspension cultures occur due to random adhesive interactions between single cells inoculated into the bioreactor (or culture flask) with spheroid assembly being a function of both cell concentration and the speed of rotation/agitation9. Such hydrodynamically assembled stem cell spheroids have been utilized widely and with considerable success for both stem cell expansion and for differentiation into a number of adult cell types including hepatocytes10,11, pancreatic β-cell12,13, cardiomyocytes14, neurons15, and erythroid cells16.
Despite their utility, the current strategies for assembly and cultivation of spheroids have several limitations: (1) not all hPSC lines efficiently and uniformly form spheroids in suspension cultures17, likely due to differences in expression of cell adhesion molecules, (2) it is difficult to enhance transport of nutrients in stirred suspension cultures without damaging spheroids with higher shear stress18, and (3) it is difficult to control spheroid diameter and size distribution in suspension cultures19. We believe that challenges mentioned above may be addressed by encapsulating hPSCs inside biomaterial scaffolds suitable for suspension cultures.
A number of reports described the use of biomaterial scaffolds containing hPSC for stem cell expansion and differentiation20,21,22,23. However, these biomaterials strategies were not designed with suspension cultures in mind. There has been considerable use of microcarriers for cultivation of hPSCs in suspension cultures24,25,26. These microcarriers (e.g. polystyrene microbeads) may be coated with components of the extracellular matrix (ECM) to promote adhesion of hPSCs, thereby ensuring that more hPSC lines may be used for suspension cultures. However, because stem cells reside on the surface of the microcarriers, they remain exposed to shear stress and may be damaged by agitation. Therefore, there is considerable benefit for placing stem cells inside the microcarriers.
Microcapsules or microparticles for cell encapsulation may be fabricated using either syringe-based or microfluidic nozzles and form uniform or complex composition with examples of the latter being core–shell and Janus-type microcapsules27,28,29,30,31. Microcapsules of uniform composition (typically hydrogel) have been used widely for encapsulation of preformed cell aggregates or single cells capable of rapid proliferation28,32.
Our team has demonstrated cultivation and differentiation of mouse embryonic stem cells (mESCs) in hydrogel microparticles32, however, we were unsuccessful in forming spheroids with encapsulated primary hepatocytes or human ESCs. We reasoned that better outcomes may be attained with microcapsules comprised of a hydrogel shell and an aqueous core where single cells could assemble into spheroids. Microcapsules composed of an alginate shell and aqueous core were demonstrated by He et al. for encapsulation and transplantation of mESCs and cancer stem cells33,34. Previously, we employed a similar co-axial flow focusing microfluidic device to fabricate microcapsules with PEG hydrogel shell and aqueous core and demonstrated that non-proliferative primary hepatocytes assembled into spheroids upon encapsulation and remained functional for at least two weeks of culture35.
In this report, we assessed the utility of the microcapsules with hydrogel shell and aqueous core for encapsulation of hPSCs (see Fig. 1A). We demonstrated successful encapsulation, spheroid formation and high viability for three different hPSC lines. Using one of the hPSC lines we demonstrated maintenance of pluripotency and successful differentiation of stem cell spheroids into β-cells. In addition, we combined a microfluidic encapsulation with dissociation/filtration module to ensure that ~ 90% of microcapsules contained spheroids. Additional experiments were carried out to demonstrate that microcapsules were protective against shear stress during cultivation in a stirred bioreactor/spinner flask. In summary, our study highlights utility and potential benefits of microfabricated capsules for establishing suspension cultures of hPSCs.
Results and discussions
Fabricating microcapsules in a flow focusing microfluidic device
We employed a microfluidic capsule fabrication strategy whereby core and shell streams co-flowed in a co-axial manner and were discretized into droplets by ejection into an oil stream35. The shell stream contained molecules of 4-arm PEG-Mal while the core flow stream contained cells, non-reactive PEG and a densifier solution for viscosity matching (see Fig. 1A). Once in the oil phase, the 4-arm PEG-Mal became crosslinked by DTT via “click” chemistry, creating a hydrogel shell region with thickness of ~ 5 μm as measured by fluorescence. Droplet uniformity is a well-known benefit of flow focusing microfluidic devices36. As shown in Fig. 1B, our flow focusing microfluidic system generated uniformly sized aqueous droplets which became crosslinked via PEG-Mal/DTT reaction and, upon breaking the emulsion, were collected as uniformly sized hydrogel microcapsules. Core–shell microcapsule has aqueous core with thin hydrogel layer. Analysis of size distribution revealed that for a given set of operational parameters (4 μL min−1 core/4 μL min−1 shell/50 μL min−1 oil flow rates) microcapsule diameters were narrowly distributed around the mean of 392.6 ± 8.2 μm with coefficient of variation of 2.08%. It is worth noting that that the tallest channel in the flow focusing microfluidic device is 300 μm which means that the resultant microparticles should have a diameter of ~ 300 μm and not 400 μm as mentioned above. This discrepancy may be explained by swelling of microparticles upon transfer from oil into aqueous phase. Figure S1 shows that capsules in the oil phase were indeed 300 μm in diameter and that the diameter increased to ~ 400 μm after 2 h in the aqueous phase. Dimensions of capsules are the function of flow rate and microfluidic channel size. 400 µm diameter capsules were chosen to accommodate hPSC spheroids that were typically in the 100 to 200 µm diameter range (see “Discussion” below).
We carried out experiments to confirm core–shell structure of the microcapsules. As shown in Fig. 1C,D PEG-TRITC present in the shell flow stream became incorporated into the hydrogel shell of a microcapsule. Microbeads present in the core flow stream were entrapped inside the microcapsule core. Importantly, as shown in Fig. 1D, microbeads sedimented and aggregated, indicating that the core was aqueous.
As the next step, we wanted to assess viability and spheroid formation for hPSCs encapsulated in our microfluidic devices. To show broad applicability, we chose to encapsulate two human embryonic stem cells (hESCs) lines (HUES-8 and H9) and one induced pluripotent stem cell (iPSC) line (1016). We note that formation of spheroid cultures in a stirred bioreactor/spinner flask is typically a function of cell concentration, stir rate and intrinsic adhesion properties of stem cells (likely related to expression of cell adhesion molecules). HUES-8 cells have been shown to assemble into spheroids at the concentration of 5 × 105 cells mL−1 with stirring speed of 70 rpm and have been used by us previously for pancreatic β-cell differentiation in suspension cultures37.
Unlike standard spheroid formation in stirred cultures which happens as result of random encounters of cells floating in a large volume of media, our encapsulation strategy confines cells to a minute volume (~ 33 nL for a capsule with 400 μm diameter), thus increasing local cell concentration and forcing cellular interactions inside capsules. As highlighted by Fig. 2A, encapsulation resulted in spheroid formation for all three hPSC lines. Live/Dead staining revealed that viability of encapsulated stem cell spheroids was 94.4 ± 7.7% for HUES-8 cells, 88.7 ± 11.8% for H9 cells and 95.7 ± 4.1 for 1016 cells, compared to 96.5 ± 5.7% for HUES8 control spheroids (see Fig. 2A,B). Viability of bare and encapsulated HUES-8 spheroids was comparable, suggesting that encapsulation had no deleterious effects on stem cell survival. Furthermore, HUES8 cells had similar viability before and after encapsulation, further supporting the notion that the microfluidic encapsulation process was not damaging to cells (see Figure S2).
As shown in Fig. 2C the diameter for encapsulated spheroids was 228.3 ± 53.3 μm (CV-23.3%) for HUES8, 161 ± 40.2 μm for H9 (CV-25%), 230.1 ± 41.7 μm for 1016 (CV-18.1%) compared to 170.5 ± 54.1 (CV-31.7) for HUES8 spheroids without capsules.
The variability in the average spheroid diameter between the cell lines is likely due to the cell-line specific differences in cell-adhesive properties.
Improving stem cell loading efficiency by integrating a microfluidic dissociation module in line with a flow focusing encapsulation device
While microfluidic encapsulation resulted in formation of highly viable stem cell spheroids, a significant fraction (~ 43%) of microcapsules did not have cells. Given the high input concentration of cells in the core flow stream (e.g. 30 or 60 × 106 cells mL−1), most, if not all microcapsules were expected to contain cells/spheroids under ideal circumstances. However, under experimental conditions, cells were observed to clump in the syringe delivering core stream into the microfluidic encapsulation device. Changing orientation of the syringe (vertical vs. horizontal) and placing syringe on ice decreased but did not eliminate cell clumping. Because of clumping, cells were not uniformly distributed in the core stream leading to some capsules being empty and other capsules carrying an excess of cells.
To address this challenge, we integrated a microfluidic dissociation/filtration device upstream of the microfluidic encapsulation device (see Fig. 3A and Figure S3). Passive filters containing arrays of posts have previously been incorporated into microfluidic devices to retain cell clumps, thus minimizing channel occlusion while cell seeding38,39,40 or as a way to mechanically digest tissues by using flow41. Using this concept, we created a dissociation device that contained an array of PDMS pillars that spanned the height of the microfluidic channel (50 μm) with pitch varying from 500 µm at the inlet to 50 µm at the outlet (Fig. 3B). COMSOL modeling revealed that at the flow rate of 3 μL min−1 shear stress levels in the device varied from 0.05 to 0.16 Pa for 500 μm and 50 μm pitch respectively (see Figure S3). The highest levels of shear generated in the filter/dissociation device were reported in the previous studies to be non-damaging to cells4.
Based on the flow rate in the dissociation device and the volume of connecting tubing, cells were expected to arrive in the encapsulation device 60 s after exiting the dissociation device—an amount of time insufficient for clumping to occur. Indeed, connecting the dissociation device in series with microfluidic encapsulation module allowed us to improve the loading efficiency from 57 to ~ 90%. The improved cell loading efficiency is highlighted by images in Fig. 3C and is quantified in Fig. 3D. The use of the dissociation device also allowed us to improve the size uniformity of encapsulated spheroids. The data in Fig. 3E show the encapsulated spheroids created using initial concentration of 60 × 106 cells mL−1 were 310.8 ± 116.5 µm in diameter (CV = 37.5%) without dissociation compared to 286.9 ± 36.2 µm in diameter (CV = 12.6%) with the dissociation device. Importantly, viability of HUES-8 cells was unaffected by the dissociation/encapsulation process (see Fig. 3F).
Having improved uniformity of spheroid formation, we proceeded to demonstrate that spheroid size may be controlled by the inoculation density of stem cells. As shown in Fig. 3G,H, HUES-8 input concentrations of 15 × 106 to 30 × 106 to 60 × 106 cells mL−1 resulted in spheroid diameters of 87.6 ± 35.6 µm, 157.2 ± 50.7 µm and 286.8 ± 36.7 µm. It is worth noting that the concentration of 15 × 106 cells·mL−1 is not sufficient to form spheroids in stirred flasks without microcapsules. Given extensive evidence of spheroid size affecting differentiation fate of hPSCs8,37,42,43, our ability to control spheroid size and uniformity will have important implications for future efforts to differentiate encapsulated spheroids.
Characterizing shear stress effects in a stirred bioreactor
Stirred bioreactors utilize agitators or impellers to disperse spheroids throughout the reactor volume while efficiently delivering nutrients and oxygen. The speed of rotation or the shear stress generated by the impeller is therefore coupled to the rate of nutrient and oxygen delivery. As a result, suspension spheroid cultures strive to identify the “safe zone” for stirring where transport is adequate and shear stress is not damaging25,44. Previously, we empirically determined that HUES-8 cells stirred at the rate of 70 rpm formed ~ 200 µm diameter spheroids that remained undamaged and healthy during the multi-day culture protocol37,45. In the present study, we wanted to understand the shear stress and transport properties in the bioreactor operating at 70 rpm and to assess how these properties change in the event of increasing stirring speed. To address these questions, we set up computational fluid dynamics (CFD) model of the bioreactor (see Fig. 4A for image of the bioreactor) in COMSOL. Modelling of oxygen transport (Figure S5) revealed that oxygenation may be improved threefold by increasing the stirring speed from 70 to 140 rpm, with oxygen concentration reaching 3 μmol (or 1 mM) in the bioreactor at 140 rpm compared to 1 μmol at 70 rpm. Modulating oxygen levels during hPSC differentiation may be particularly useful given that cultures at early developmental stages have been shown to benefit from hypoxia while resultant adult cells (e.g. pancreatic β-cells or hepatocytes) have high demands for oxygen46,47.
Additional CFD modeling (see Fig. 4B) revealed magnitude of velocity within the reactor at stirrer speeds of 70 and 140 rpm, 3 s after stirring was initiated. An earlier time was chosen to show the development of mixing in the bioreactor as well as to show key differences between the stirrer speeds. In general, highest velocity magnitudes were seen on the impeller blades farthest from the rotating axis. This is expected as the tangential velocity at the tip of an impeller is proportional to radial distance from the axis of rotation. These results highlight that velocity profile inside the stirred bioreactor is complex/non-uniform. The peak velocity and shear stress dependence on the stirring speed at t > 5 s after initiation of stirring is described in Fig. 4C. It is worth noting that shear stress in the range of ~ 3 Pa has previously been reported damaging to cells cultured in suspension stirred bioreactors18. When modeling exposure of individual spheroids to peak bioreactor velocities, heterogeneous surface shear stress profiles were predicted (Fig. 4D). Subjecting spheroids to the peak velocity under a stirrer speed of 140 rpm produced relatively high local shear stresses (~ 10 Pa) on spheroid surfaces. We therefore expected to observe shear stress effects in suspension cultures at higher speed of rotation.
To experimentally confirm the effects of shear stress in our bioreactor, bare and encapsulated HUES-8 spheroids were cultured for 8 days at either 70 rpm or 140 rpm. Images in Fig. 5A highlight the differences between experimental groups: (1) bare spheroids stirred at 70 rpm were larger than those spheroids cultured at 140 rpm, (2) encapsulated spheroids were of similar diameter for both stirring conditions. Quantification of spheroid sizes (see Fig. 5B) revealed that no significant differences existed between diameters of encapsulated spheroids cultured for 3 days at 70 and 140 rpm (158.2 ± 11.3 µm vs. 156.8 ± 9.1 µm). By contrast, the diameters for bare spheroids were 159.8 ± 7.4 and 90.4 ± 2.8 μm for 70 and 140 rpm respectively. This result points to the effects of shear on bare spheroids at higher speeds of rotation and highlights the protection from the shear stress provided by the hydrogel microcapsule. During this experiment, we did not observe appreciable damage (e.g. rapture) of microcapsules at 140 rpm and can infer that the microcapsules are mechanically strong enough to withstand the shear stress in excess of 3 Pa.
Assessing pluripotency expression and differentiation potential of hPSC spheroids
In the preceding sections of the paper we demonstrated that microcapsules may be leveraged to ensure spheroid formation and improve spheroid size uniformity as well as to protect cells against shear stress. In this section, we wanted to evaluate pluripotency state and differentiation of encapsulated hPSCs in comparison with unencapsulated spheroids. We considered two types of hPSC spheroid controls without capsules for these experiments. Control 1—hPSCs placed into syringe containing core components (densifier, non-crosslinkable high MW PEG) for the duration of the encapsulation run (~ 1 h) and then formed into spheroids in a bioreactor. Control 2—hPSCs formed into spheroids in a bioreactor without prior exposure to chemicals present during microencapsulation. Comparison of pluripotency and endodermal gene expression revealed no significant differences between the two types of control conditions (see Figure S6). Therefore, we used spheroids directly formed in the bioreactor as controls for encapsulated spheroids. We should also note that all pluripotency and differentiation experiments described below were carried out with HUES-8 cells.
Having identified appropriate control conditions, we proceeded to assess pluripotency state and differentiation potential of encapsulated spheroids. In the first set of experiments (see Fig. 6A), hPSC spheroids were cultured in pluripotency maintenance media (mTeSR) for 3 days and then transferred to endodermal differentiation media containing activin A for another 3 days. Pluripotency and endodermal gene expression was monitored by RT-PCR over the course of this experiment. Characterization of gene expression revealed an expected trend for both encapsulated and control spheroids—expression of pluripotency genes (OCT4, SOX2, NANOG) was high with cells in pluripotency (mTeSR) media at days 1 and 3 but then decreased after spheroids were transferred into endodermal differentiation media during subsequent 3 days (Fig. 6B,C). Conversely, expression of endodermal genes (SOX17, GATA4, CXCR4) was low in pluripotency media at days 1 and 3 but high at day 6 after endodermal differentiation. While statistically significant differences in pluripotency gene expression were observed between control and encapsulated spheroids, no trend pointing to one condition being better than the other could be discerned (Fig. 6B). SOX2 expression was higher at day 3 in encapsulated spheroids whereas OCT4 and NANOG exhibited higher expression at day 3 in control spheroids. Importantly, induction of endoderm drove endodermal gene expression of encapsulated spheroids to the level similar or better than control spheroids (see Fig. 6C). This result supports the notion that microencapsulation does not adversely affect pluripotency state and endodermal differentiation of hPSC spheroids. Further evidence for this is provided by β-cell differentiation experiments described below.
In the second set of experiments, encapsulated hPSC spheroids were directed toward pancreatic β-cell lineage using a previously multi-stage differentiation protocol described in Fig. 7A and previously published reports12,37. In this protocol, stem cell spheroids cultured in a stirred bioreactor were guided by sequential and timed administration of inductive signals through a series of developmental stages reminiscent of endocrine pancreatic development. These stages were: definitive endoderm (DE), primitive gut tube (PGT) formation, pancreatic progenitor (PP) stages 1 and 2, endocrine progenitor stage (EN) and a stem cell-derived β-cell stage (SC-β). At the end of the protocol (after 26 days), β-cell markers and function were characterized for control and encapsulated spheroids.
Figure 7B shows representative images of encapsulated spheroids at different times during differentiation. It may be appreciated from these images that over the course of 4 weeks, spheroids undergo significant changes in size/morphology and that capsules accommodate such changes and remain structurally intact for at least three weeks. As seen from Fig. 7B capsules begin experiencing structural breakdown after 4 weeks of culture. This breakdown is likely caused by continued stretching of the hydrogel shell by the growing spheroids and may be mitigated in the future by increasing capsule diameter or decreasing hPSC inoculation density.
The presence of the hydrogel shell is desirable for diabetes-related applications where β-cells are typically transplanted ectopically, function in an endocrine manner and benefit from immunoprotective coatings. However, other applications involving tissue regeneration or repair may call for degradable capsules. Several strategies for designing degradable hydrogels have been reported in the literature and may be pursued in the future to degrade spheroid-carrying microcapsules48,49,50,51,52.
Efficiency or yield of β-cell differentiation was assessed by flow cytometry and immunofluorescence staining. Flow cytometry revealed that in-capsule differentiation resulted in 17% of cells expressing pancreatic β-cell markers insulin and NKX6.1 and these cells were negative for glucagon—a marker of pancreatic α-cells. Importantly, populations of NKX6.1+ insulin+ and glucagon− insulin+ cells were similar for encapsulated and control spheroids, 17% and 21% respectively (Fig. 7C). Immunofluorescent staining and imaging of intact spheroids confirmed that a large fraction of cells within a spheroid stained positive for β-cell markers, NKX6.1 and insulin (Fig. 7D).
To further assess functionality of β-cells, we carried out glucose stimulation insulin secretion (GSIS) analysis where insulin secretory capacity of the cells is evaluated by sequential glucose challenges followed by depolarization with KCl37. Figure 7E summarizes results of GSIS analysis for encapsulated and control spheroids. As seen from these data, both types of spheroids secreted insulin in response to glucose challenges with secretion index of 2.99 and 3.57 for control and encapsulated spheroids respectively. This result provides additional evidence in support of encapsulation process being compatible with production of highly functional cells exhibiting markers of pancreatic β-cells.
Conclusions
In this study we sought to address the need for an hPSC encapsulation technology that would result in formation of viable stem cell spheroids of uniform and tunable size. We also assessed the utility of microcapsules for shielding cell spheroids against shear stress in the stirred bioreactor. To achieve the goals of this study, we utilized a flow focusing microfluidic device to fabricate microcapsules with a hydrogel shell and an aqueous core. These microcapsules were shown to be conducive to rapid aggregation of hPSCs into spheroids. Successful encapsulation and formation of high viability spheroids was demonstrated for three different hPSC lines.
The challenge of inefficient cell loading due to clumping, experienced by us during initial phase of this study, was resolved by integrating a dissociation device in line with and upstream of the microencapsulation device. By using this integrated encapsulation platform, the frequency of spheroid-containing capsules was improved from 57 to 90% while the distribution of spheroid size narrowed from 310.8 ± 116.5 to 286.9 ± 36.2 µm in diameter for high density loading.
In addition, we carried out CFD modeling of transport in the stirred bioreactor used for cultivation of spheroids. This modeling predicted that the increase in stirring speed may result in shear stress levels that are damaging to stem cell spheroids and potentially improve the oxygenation of the stirred bioreactor. We then demonstrated experimentally that such damage is observed in bare spheroids which decrease in size at higher stirring speeds but is not observed in encapsulated spheroids. Our experimental results suggest that hydrogel shell of the microcapsules is shielding spheroids from the shear stress reaching 3 Pa. The use of hydrogel microcapsules offers the benefit of regulating/improving transport properties without damaging the cells, thus allowing one to uncouple transport from shear stress in a stirred bioreactor.
Importantly, encapsulation did not affect pluripotency state and differential potential of hPSC spheroids. The latter point was highlighted by successful differentiation of encapsulated hPSC spheroids into cells expressing markers and function of pancreatic β-cells.
In the future, the microcapsules may be further improved for ease of hydrogel degradation/spheroid retrieval as well as for controlled loading and release of inductive signals. The microcapsules may also be used as vehicles for transplantation of stem-cell derived adult cells into immune competent animal models.
Experimental section
Fabrication of microencapsulation devices
Microencapsulation flow-focusing devices were fabricated according to a previously described protocol35. The polydimethylsiloxane (PDMS) microfluidic device consists of two mirrored triple-height PDMS microfluidic devices bonded together to achieve a non-planar (3D) flow-focusing device. Briefly, the microfluidic device was designed in AutoCAD (version 2019, Autodesk Inc.). Based on device design, two master molds, original design (top) and mirror of it (bottom), were fabricated by multi-step photolithography using SU-8 2050 photoresist (MicroChem, Westborough, MA) to achieve three different heights: (1) 50 µm for aqueous core solution, (2) 100 µm for aqueous shell solution and (3) 150 µm for oil phase. Two 4-inch silicon wafers (University Wafer, USA) were spin coated with a 50 µm layer of photoresist, soft baked (5 min at 65 °C, 10 min at 95 °C) and exposed to UV light through a photomask with the desired structures using a mask aligner (UV-KUB 3, Kloé, France). A post exposure bake was performed to both molds for 3 min at 65 °C and 10 min at 95 °C. Features were developed by direct submersion in SU-8 developer (MicroChem, Westborough, MA) until unexposed photoresist was completely removed. Afterwards, a 100 µm layer of photoresist was spin coated on top of the 50 µm layer and structures were exposed with a similar protocol to the one just described, changing soft bake to 5 min at 65 °C and 20 min at 95 °C. The third photoresist layer of 150 µm was spin coted on top of the previous two and a similar protocol was followed to expose structures, changing soft bake (5 min at 65 °C, 30 min at 95 °C) and post exposure bake (5 min at 65 °C, 15 min at 95 °C) times. Finally, both molds were placed on a hot plate at 160 °C for 10 min as hard bake, followed by exposure to chlorotrimethylsilane for 30 min on a closed chamber to avoid PDMS adhesion to master molds.
After mold fabrication, PDMS (Sylgard 184 silicone elastomer kit, Dow Corning) replicas were fabricated by soft lithography53. For this, 55 g of PDMS mixture with a ratio of 10 to 1 of base and curing agent was poured into each master mold, degassed for 10 min on a vacuum desiccator and baked for 60 min at 80 °C on a convection oven. Cured “top” and “bottom” PDMS pieces were cut, inlets and outlets punched out and treated with oxygen plasma for 45 s (G-500 plasma cleaning system, Yield Engineering Systems, Livermore, CA). PDMS pieces were manually aligned under stereoscope (Zeiss Stemi 508, Germany) using deionized water as a lubricating layer. Aligned PDMS devices were then placed in an oven at 80 °C overnight to remove water layer.
Final PDMS microencapsulation devices contained channel with three heights: (1) 100 µm for aqueous core channel, (2) 200 µm for aqueous shell channels, and (3) 300 µm for oil and capsule collection channels. Microencapsulation devices were placed on a glass slide for handling and channels are treated with Aquapel solution previous to use to render the surfaces hydrophobic.
Fabrication of dissociation/filtering devices
To improve cell-seeding into capsules, a microfluidic dissociation device was fabricated. The microfluidic filter consists of a single layer device with a height of 50 µm, fabricated with the same protocol as the microencapsulation device. The device comprises a simple rectangular chamber with an inlet and an outlet, as shown in Figure S1. The chamber contained an array of posts with larger diameter and larger separation towards the inlet, becoming smaller in diameter and closer to each other closer to the outlet of the device. This array of posts allowed trapping and dissociation of larger cell aggregates while letting cell clumps < 50 μm enter the encapsulation system.
Microfluidic encapsulation of hPSCs
We followed a previously described protocol35 for encapsulation of hPSCs. Briefly, the core and shell fluids were a 50:50 ratio of 16% w/v PEG (35 kDa) and 34% Optiprep densifier (Sigma-Aldrich, St. Louis, MO) dissolved in Krebs–Ringer bicarbonate (KRB) buffer and 10% (range 7–12%) w/v 4-arm maleimide functionalized poly(ethylene glycol) (PEG 10 k) and 15 mM triethanolamine (TEA) (range 10–20%) dissolved in DI water, respectively. The shielding oil phase at the second flow-focusing cross-section consisted of mineral oil and 1.5% (w/v) of surfactant Span80 (Sigma-Aldrich, St. Louis, MO). To make the crosslinking oil for flowing in the crosslinking channel a solution of mineral oil with 3% (w/v) Span-80 mixed with dithiothreitol (DTT) (Ratio of 1:15 emulsion of 25 mg mL−1 DTT) dissolved in DI water was prepared by sonication for 45–60 min in an ultrasonic bath at 20 °C. All the solutions are injected into the inlets of the microfluidic device through Tygon Microbore Tubing (Dimensions: 0.020″ ID × 0.060″ OD). Flow rates of the streams were regulated via syringe pumps (Harvard Apparatus, Holliston, MA) at the following rates: core: 3–5 μL min−1, shell: 3–5 μL min−1, shielding oil: 30–50 μL min−1, and crosslinking oil: 40–60 μL min−1.
Cell suspensions were loaded into the core solutions at three different concentrations: low (15–20 × 106 cells mL−1), medium (30–35 × 106 cells mL−1) and high (50–60 × 106 cells mL−1). At the experimental flow rates, the frequency of our core/shell microencapsulation is ~ 5–6 capsules per second with each capsule containing ~ 300 cells at medium cell concentration (see below). For medium cell concentration, ~ 7.6 × 106 cells could be encapsulated in 1 h of operating the microfluidic system.
HPSCs tended to aggregate in the syringe before reaching the encapsulation system causing a significant fraction (~ 43%) of capsules to be empty of cells. The aggregation was decreased, but not eliminated, by keeping cells at 4 °C. Dissociation/filter microfluidic module was used to address this challenged. The dissociation and microencapsulation units were integrated using 5–7 cm Tygon Microbore Tubing (Dimensions: 0.020″ ID × 0.060″ OD), with one end of the tube placed into the outlet of the dissociation device and the other end inserted in the “core” flow input of the encapsulation device. Therefore, shell and oil solutions were directly injected into the encapsulation device whereas core solution with stem cells was routed through the dissociation device first. Core solutions loaded with cell suspensions were perfused using a syringe pump (Harvard Apparatus, USA) at a flow rate of 4 µL min−1.
Cultivation of hPSC spheroids
HUES-8 and H9 cells (both hESC lines) as well as 1016 (hiPSC line) were cultured as spheroids in 30 mL spinner flasks (ABLE Biott, Japan). Suspension cultures were established by seeding 15 million cells (5 × 105 cells mL−1) in mTeSR media (STEMCELL Technologies, Vancouver, Canada) with 10 µM Y27632 (STEMCELL Technologies, Vancouver, Canada). The spinner flasks were placed on a stir plate at the speed of 70 rpm inside the humidified incubator at 37 °C, and 5% CO2. Media was changed at 48 h to mTeSR without Y27632. Cells were passaged every 72 h by dispersing to single cells using Accutase and resuspended in fresh mTeSR with Y27632.
When assessing effects of shear stress, stem cells spheroids were kept in mTeSR media for 3 days. For additional 5 days, spheroids were maintained in the MCDB131-based media with additives described in detail in our previous work as S1 media37. The latter media was used to minimize proliferation of spheroids.
Assessing cell viability
A live/dead cell imaging kit (488/570, Thermo Fisher Scientific) was used to assess cell viability of microcapsules with stem cell spheroids. Staining solution was prepared on a 15 mL tube by mixing 10 mL of media, 20 µL of ethidium homodimer and 5 µL of Calcein-AM (Live/Dead Viability/Cytotoxicity Kit, Thermo Fisher Scientific). Microcapsules were placed in the media and incubated for 30 min at room temperature. Staining solution was washed using 1X PBS. The bright-field and fluorescence images were taken using an inverted microscope (IX-83, Olympus).
Bioreactor modeling and fluid dynamics simulations
Two types of simulations were carried out to determine the effect of mixing on microcapsules. In the first simulation, a model of the bioreactor was constructed. The bioreactor used in the experiments has a magnetically driven stirrer (ABLE Biott, Japan) and has a nominal volume of 30 mL. The reactor and the stirrer were 3D-scanned and a geometric model was constructed in COMSOL (COMSOL, MA). Computational fluid dynamics simulations were carried out using the CFD module in COMSOL under isothermal laminar flow conditions using material properties of water (incompressible Newtonian fluid). The rotational speed was varied: 10, 30, 70 and 140 rpm. Unsteady simulations were carried out with the rotational speed at t > 0 set to the prescribed value for > 5 s. Mesh optimization was carried out using various physics-based sizing options (coarse, normal, fine and extra-fine) within the software. A mesh size of normal was deemed to be sufficient; no appreciable changes in results were observed by further reducing the mesh size. Peak velocity in the bioreactor for each rotational speed was determined. To determine the shear stress profiles around the microcapsules, in the second simulation, a model of microcapsule was constructed and exposed to the peak velocity in a volume relatively large (10×) to its size. The above twostep process allowed us to separately obtain reactor and microcapsule-specific information.
Analysis of pluripotency
Pluripotency of encapsulated and bare spheroids was assessed by RT-PCR. Both types of spheroids were cultured for up to 3 days in stirred bioreactor in mTeSR media and then collected for analysis. The microcapsules were first broken by mechanical agitation (pipetting up and down). Liberated cells were then lysed and total RNA was isolated using mRNA extraction kit (Roche). The RNA abundance and quality were assessed by NanoDrop UV–Vis spectrophotometer (Thermo Fisher Scientific).
The total mRNA was then converted to cDNA using a Transcriptor First Strand cDNA synthesis kit (Roche) and analyzed using a QuantStudio 3 Real-Time PCR System (Thermo Fisher Scientific) for the expression of OCT4, NANOG and SOX2 genes. Predesigned TaqMan probes for pluripotency genes were purchased from Thermo Fisher. Pluripotency gene expression was quantified relative to GAPDH housekeeping gene using the ∆∆Ct method.
Endodermal and β-cell differentiation of hPSC spheroids
HUES-8 cells were used for all differentiation experiments described below. The differentiation began after 3 days of stem cell spheroid formation and expansion in mTeSR media inside a stirred bioreactor. Approximately 60 × 106 cells were present in the bioreactor during a differentiation run. We followed previously described differentiation protocols37,54. Basal media types, numbered S1, S2, S3, and BE5; and were supplemented with inductive signals as described below.
S1 media, was comprised of 500 mL MCDB 131 supplemented with 0.22 g glucose, 1.23 g sodium bicarbonate, 10 g fatty acid free bovine serum albumin (FAF-BSA, Proliant Biologicals), 10 μL ITS-X, 5 mL GlutaMAX, 22 mg ascorbic acid, and 5 mL penicillin/streptomycin (P/S) solution. S2 media: 500 mL MCDB 131 supplemented with 0.22 g glucose, 0.615 g sodium bicarbonate, 10 g FAF-BSA, 10 μL ITS-X, 5 mL GlutaMAX, 22 mg ascorbic acid, and 5 mL P/S. S3 media: 500 mL MCDB 131 supplemented with 0.22 g glucose, 0.615 g sodium bicarbonate, 10 g FAF-BSA, 2.5 mL ITS-X, 5 mL GlutaMAX, 22 mg ascorbic acid, and 5 mL P/S. BE5 media: 500 mL MCDB 131 supplemented with 1.8 g glucose, 0.877 g sodium bicarbonate, 10 g FAF-BSA, 2.5 mL ITS-X, 5 mL GlutaMAX, 22 mg ascorbic acid, 5 mL P/S, and 2000 units heparin (MilliporeSigma).
Directed differentiation of pluripotent stem cells to SC-β cells was performed by changing media within the spinner flask and supplementation with small molecules and growth factors specific to the differentiation stage. Media changes are as follows: Day 1: S1 media + 100 ng/mL Activin A + 3 mM CHIR99021; Day 2: S1 media + 100 ng/mL Activin A; Day 4: S2 media + 50 ng/mL KGF; Day 6: S3 media + 50 ng/mL KGF + 250 nM Sant-1 + 500 nM PDBu + 200 nM LDN 193189 + 2 µM RA + 10 µM Y27632; Day 7: S3 media + 50 ng/mL KGF + 250 nM Sant-1 + 500 nM PDBu + 2 µM RA + 10 µM Y27632; Days 8, 10, 12: S3 media + 50 ng/mL KGF + 250 nM Sant-1 + 100 nM RA + 10 µM Y27632 + 5 ng/mL Activin A; Days 13 + 15: BE5 media + 250 nM Sant-1 + 20 ng/mL betacellulin + 1 µM XXI + 10 µM ALK5i + 1 µM T3 + 100 nM RA; Days 17 + 19: 20 ng/mL betacellulin + 1 µM XXI + 10 µM ALK5i + 1 µM T3 + 25 nM RA; Days 20–26: S3 media only. KGF (cat # 100-19) was purchased from Peprotech, all other factors were purchased from R&D Systems with the following catalog numbers: Activin A (338-AC), CHIR (4423), SANT-1 (1974), PDBu (4153), RA, Retinoic Acid (0695), LDN, LDN193189 (6053), Y27632 (1254), Betacellulin (261-CE), ALK5i (3742), T3, L-3,3',5-Triiodothyronine (5552), XXI, γ-secretase inhibitor XXI (6476).
Endodermal phenotype was characterized after 3 days of differentiation by expression of SOX17, GATA4 and CXCR4 genes by RT-PCR. Predesigned TaqMan probes for these genes were purchased from Thermo Fisher. Gene expression was normalized by the GAPDH housekeeping gene using the ∆∆Ct method.
Flow cytometry
After completion of the differentiation protocol, microcapsules were pipetted up and down to break the hydrogel shell and release spheroids. The spheroids were then dispersed into single-cells by incubation in TrypLE at 37 °C 15 min. Cell were fixed in 4% PFA for 20 min and stored at 4 °C until further use. Prior to staining, cells were incubated in the blocking solution (1x PBS, 0.1% Triton X-100, 5% donkey serum) at room temperature for 40 min and then washed in 1x PBS with 0.1% Triton X-100T. Cells were then incubated with primary antibodies in the blocking solution (see above) for 1 h at room temperature, washed twice with 1x PBS, 0.1% Triton X-100 and incubated with secondary antibodies in the block solution for 1 h at RT. The following primary antibodies were used for flow cytometry: rat anti-human antibody for insulin (DSHB, cat# GN-ID4), goat anti-human antibody for glucagon (Sigma, cat# G2654) and mouse anti-human antibody for NKX 6.1 (DSHB, cat#F55A12). Secondary antibodies used for flow cytometry were donkey-anti-rat-Alexa Fluor 488 (1:1000) and donkey-anti-mouse-Alexa Fluor 647. After labeling, cells were washed three times, resuspended in 1x PBS with 0.01% Tween 20 at a concentration of 1 × 106 cells/mL and analyzed using Attune low cytometer.
Immunostaining
Encapsulated and unencapsulated spheroids were placed into 4% PFA for 20 min for fixation and were then washed in 1x PBS. Spheroids were then embedded in Histogel, transferred into paraffin and sectioned into 5 μm slices using microtome. Sections were stained for insulin and NKX 6.1 using the antibodies and protocols described above and were mounted in Fluoromount-G with DAPI. Clusters were imaged using an inverted fluorescence microscope (IX-83, Olympus).
Glucose stimulation insulin section experiments
Detailed protocols for glucose stimulation insulin secretion experiments are described elsewhere37. Briefly, approximately 106 cells were placed into a transwell and allowed to equilibrate in low KRB (Krebs–Ringer Buffer) for 1 h. Following the initial equilibration period, transwells were transferred sequentially to KRB buffer containing low glucose (3.3 mM) high glucose (16.7 mM) and KCl (30 mM KCl). Following incubation, aliquots were taken from each well and analyzed for insulin using ELISA (ALPCO- Human Ultrasensitive Insulin).
Statistical analysis
Data are represented as mean ± SD and mean ± SEM. Statistical significance between experimental groups was assessed using a two-tailed student’s t-tests and p values < 0.05 were considered statistically significant.
References
Glorevski, N. et al. Designer matrices for intestinal stem cell and organoid culture. Nature 539, 560–564. https://doi.org/10.1038/nature20168 (2016).
Bratt-Leal, A. M., Carpenedo, R. L. & McDevitt, T. C. Engineering the embryoid body microenvironment to direct embryonic stem cell differentiation. Biotechnol. Prog. 25, 43–51. https://doi.org/10.1002/btpr.139 (2009).
Simunovic, M. & Brivanlou, A. H. Embryoids, organoids and gastruloids: new approaches to understanding embryogenesis. Development 144, 976–985. https://doi.org/10.1242/dev.143529 (2017).
Kehoe, D. E., Jing, D., Lock, L. T. & Tzanakakis, E. S. Scalable stirred-suspension bioreactor culture of human pluripotent stem cells. Tissue Eng. Part A 16, 405–421. https://doi.org/10.1089/ten.TEA.2009.0454 (2010).
Rodrigues, C. A. V., Fernandes, T. G., Diogo, M. M., da Silva, C. L. & Cabral, J. M. S. Stem cell cultivation in bioreactors. Biotechnol. Adv. 29, 815–829. https://doi.org/10.1016/j.biotechadv.2011.06.009 (2011).
Wang, Y. et al. Scalable expansion of human induced pluripotent stem cells in the defined xeno-free E8 medium under adherent and suspension culture conditions. Stem Cell Res. 11, 1103–1116. https://doi.org/10.1016/j.scr.2013.07.011 (2013).
Sargent, C. Y. et al. Hydrodynamic modulation of embryonic stem cell differentiation by rotary orbital suspension culture. Biotechnol. Bioeng. 105, 611–626. https://doi.org/10.1002/bit.22578 (2010).
Chen, V. C. et al. Development of a scalable suspension culture for cardiac differentiation from human pluripotent stem cells. Stem Cell Res. 15, 365–375. https://doi.org/10.1016/j.scr.2015.08.002 (2015).
Pettinato, G., Wen, X. J. & Zhang, N. Engineering strategies for the formation of embryoid bodies from human pluripotent stem cells. Stem Cells Dev. 24, 1595–1609. https://doi.org/10.1089/scd.2014.0427 (2015).
Vosough, M. et al. Generation of functional hepatocyte-like cells from human pluripotent stem cells in a scalable suspension culture. Stem Cells Dev. 22, 2693–2705. https://doi.org/10.1089/scd.2013.0088 (2013).
Torizal, F. G., Kimura, K., Horiguchi, I. & Sakai, Y. Size-dependent hepatic differentiation of human induced pluripotent stem cells spheroid in suspension culture. Regen. Ther. 12, 66–73. https://doi.org/10.1016/j.reth.2019.04.011 (2019).
Veres, A. et al. Charting cellular identity during human in vitro β-cell differentiation. Nature 569, 368–373. https://doi.org/10.1038/s41586-019-1168-5 (2019).
Hogrebe, N. J., Augsornworawat, P., Maxwell, K. G., Velazco-Cruz, L. & Millman, J. R. Targeting the cytoskeleton to direct pancreatic differentiation of human pluripotent stem cells. Nat. Biotechnol. https://doi.org/10.1038/s41587-020-0430-6 (2020).
Halloin, C. et al. Continuous WNT control enables advanced hPSC cardiac processing and prognostic surface marker identification in chemically defined suspension culture. Stem Cell Rep. 13, 366–379. https://doi.org/10.1016/j.stemcr.2019.06.004 (2019).
Rigamonti, A. et al. Large-scale production of mature neurons from human pluripotent stem cells in a three-dimensional suspension culture system. Stem Cell Rep. 6, 993–1008. https://doi.org/10.1016/j.stemcr.2016.05.010 (2016).
Sivalingam, J. & Oh, S. Development of a scalable agitation suspension culture differentiation platform for generating erythroid cells from O-negative human induced pluripotent stem cells. Cytotherapy 21, S18. https://doi.org/10.1016/j.jcyt.2019.03.589 (2019).
Meng, G. L., Liu, S. Y., Poon, A. & Rancourt, D. E. Optimizing human induced pluripotent stem cell expansion in stirred-suspension culture. Stem Cells Dev. 26, 1804–1817. https://doi.org/10.1089/scd.2017.0090 (2017).
Kehoe, D. E., Jing, D., Lock, L. T. & Tzanakakis, E. S. Scalable stirred-suspension bioreactor culture of human pluripotent stem cells. Tissue Eng. Part A 16, 405–421. https://doi.org/10.1089/ten.tea.2009.0454 (2010).
Sargent, C. Y. et al. Hydrodynamic modulation of embryonic stem cell differentiation by rotary orbital suspension culture. Biotechnol. Bioeng. 105, 611–626. https://doi.org/10.1002/bit.22578 (2010).
Lei, Y. G. & Schaffer, D. V. A fully defined and scalable 3D culture system for human pluripotent stem cell expansion and differentiation. Proc. Natl. Acad. Sci. U. S. A. 110, E5039–E5048. https://doi.org/10.1073/pnas.1309408110 (2013).
Kerscher, P. et al. Direct hydrogel encapsulation of pluripotent stem cells enables ontomimetic differentiation and growth of engineered human heart tissues. Biomaterials 83, 383–395. https://doi.org/10.1016/j.biomaterials.2015.12.011 (2016).
Lin, H. et al. Hydrogel-based bioprocess for scalable manufacturing of human pluripotent stem cell-derived neural stem cells. ACS Appl. Mater. Interfaces 10, 29238–29250. https://doi.org/10.1021/acsami.8b05780 (2018).
Lin, H. et al. A scalable and efficient bioprocess for manufacturing human pluripotent stem cell-derived endothelial cells. Stem Cell Rep. 11, 454–469. https://doi.org/10.1016/j.stemcr.2018.07.001 (2018).
Badenes, S. M., Fernandes, T. G., Rodrigues, C. A. V., Diogo, M. M. & Cabral, J. M. S. Microcarrier-based platforms for in vitro expansion and differentiation of human pluripotent stem cells in bioreactor culture systems. J. Biotechnol. 234, 71–82. https://doi.org/10.1016/j.jbiotec.2016.07.023 (2016).
Fan, Y., Hsiung, M., Cheng, C. & Tzanakakis, E. S. Facile engineering of xeno-free microcarriers for the scalable cultivation of human pluripotent stem cells in stirred suspension. Tissue Eng. Part A 20, 588–599. https://doi.org/10.1089/ten.TEA.2013.0219 (2014).
Badenes, S. M. et al. Long-term expansion of human induced pluripotent stem cells in a microcarrier-based dynamic system. J. Chem. Technol. Biotechnol. 92, 492–503. https://doi.org/10.1002/jctb.5074 (2017).
Seiffert, S., Thiele, J., Abate, A. R. & Weitz, D. A. Smart microgel capsules from macromolecular precursors. J. Am. Chem. Soc. 132, 6606–6609 (2010).
Ma, M. et al. Core-shell hydrogel microcapsules for improved islets encapsulation. Adv. Healthc. Mater. 2, 667–672. https://doi.org/10.1002/adhm.201200341 (2013).
Nguyen, D. K., Son, Y. M. & Lee, N. E. Hydrogel encapsulation of cells in core–shell microcapsules for cell delivery. Adv. Healthc. Mater. 4, 1537–1544. https://doi.org/10.1002/adhm.201500133 (2015).
Chen, Q. et al. Controlled assembly of heterotypic cells in a core-shell scaffold: organ in a droplet. Lab Chip 16, 1346–1349. https://doi.org/10.1039/c6lc00231e (2016).
Bah, M. G., Bilal, H. M. & Wang, J. Fabrication and application of complex microcapsules: a review. Soft Matter 16, 570–590. https://doi.org/10.1039/c9sm01634a (2020).
Siltanen, C. et al. Microfluidic fabrication of bioactive microgels for rapid formation and enhanced differentiation of stem cell spheroids. Acta Biomater. 34, 125–132. https://doi.org/10.1016/j.actbio.2016.01.012 (2016).
Agarwal, P. et al. One-step microfluidic generation of pre-hatching embryo-like core–shell microcapsules for miniaturized 3D culture of pluripotent stem cells. Lab Chip 13, 4525–4533 (2013).
Rao, W. et al. Enhanced enrichment of prostate cancer stem-like cells with miniaturized 3D culture in liquid core-hydrogel shell microcapsules. Biomaterials 35, 7762–7773 (2014).
Siltanen, C. et al. One step fabrication of hydrogel microcapsules with hollow core for assembly and cultivation of hepatocyte spheroids. Acta Biomater. 50, 428–436. https://doi.org/10.1016/j.actbio.2017.01.010 (2017).
Takeuchi, S., Garstecki, P., Weibel, D. B. & Whitesides, G. M. An axisymmetric flow-focusing microfluidic device. Adv. Mater. 17, 1067–1072 (2005).
Pagliuca, F. W. et al. Generation of functional human pancreatic beta cells in vitro. Cell 159, 428–439. https://doi.org/10.1016/j.cell.2014.09.040 (2014).
Mazutis, L. et al. Single-cell analysis and sorting using droplet-based microfluidics. Nat. Protoc. 8, 870–891. https://doi.org/10.1038/nprot.2013.046 (2013).
Sturzenegger, F., Robinson, T., Hess, D. & Dittrich, P. S. Membranes under shear stress: visualization of non-equilibrium domain patterns and domain fusion in a microfluidic device. Soft Matter 12, 5072–5076. https://doi.org/10.1039/C6SM00049E (2016).
Sinha, N., Subedi, N., Wimmers, F., Soennichsen, M. & Tel, J. A pipette-tip based method for seeding cells to droplet microfluidic platforms. JoVE https://doi.org/10.3791/57848 (2019).
Lin, C.-H., Lee, D.-C., Chang, H.-C., Chiu, I.-M. & Hsu, C.-H. Single-cell enzyme-free dissociation of neurospheres using a microfluidic chip. Anal. Chem. 85, 11920–11928. https://doi.org/10.1021/ac402724b (2013).
Warmflash, A., Sorre, B., Etoc, F., Siggia, E. D. & Brivanlou, A. H. A method to recapitulate early embryonic spatial patterning in human embryonic stem cells. Nat. Methods 11, 847–854. https://doi.org/10.1038/nmeth.3016 (2014).
Hwang, Y.-S. et al. Microwell-mediated control of embryoid body size regulates embryonic stem cell fate via differential expression of WNT5a and WNT11. Proc. Natl. Acad. Sci. 106, 16978–16983. https://doi.org/10.1073/pnas.0905550106 (2009).
Fernandes-Platzgummer, A., Diogo, M. M., Baptista, R. P., da Silva, C. L. & Cabral, J. M. Scale-up of mouse embryonic stem cell expansion in stirred bioreactors. Biotechnol. Prog. 27, 1421–1432. https://doi.org/10.1002/btpr.658 (2011).
Peterson, Q. P. et al. A method for the generation of human stem cell-derived alpha cells. Nat. Commun. 11, 2241. https://doi.org/10.1038/s41467-020-16049-3 (2020).
Francis, K. R. & Wei, L. Human embryonic stem cell neural differentiation and enhanced cell survival promoted by hypoxic preconditioning. Cell Death Dis. 1, e22–e22. https://doi.org/10.1038/cddis.2009.22 (2010).
Sweet, I. R. et al. Continuous measurement of oxygen consumption by pancreatic islets. Diabetes Technol. Ther. 4, 661–672. https://doi.org/10.1089/152091502320798303 (2002).
Kloxin, A. M., Tibbitt, M. W., Kasko, A. M., Fairbairn, J. A. & Anseth, K. S. Tunable hydrogels for external manipulation of cellular microenvironments through controlled photodegradation. Adv. Mater. 22, 61–66. https://doi.org/10.1002/adma.200900917 (2010).
Shin, D. S. et al. Photodegradable hydrogels for capture, detection, and release of live cells. Angew. Chem. Int. Ed. 53, 8221–8224 (2014).
Siltanen, C., Shin, D. S., Sutcliffe, J. & Revzin, A. Micropatterned photodegradable hydrogels for the sorting of microbeads and cells. Angew. Chem. 125, 9394–9398 (2013).
You, J. et al. Bioactive photodegradable hydrogel for cultivation and retrieval of embryonic stem cells. Adv. Funct. Mater. 25, 4650–4656 (2015).
Raman, R. et al. Light-degradable hydrogels as dynamic triggers for gastrointestinal applications. Sci. Adv. 6, eaay0065. https://doi.org/10.1126/sciadv.aay0065 (2020).
Qin, D., Xia, Y. N. & Whitesides, G. M. Soft lithography for micro- and nanoscale patterning. Nat. Protoc. 5, 491–502. https://doi.org/10.1038/nprot.2009.234 (2010).
Velazco-Cruz, L. et al. Acquisition of dynamic function in human stem cell-derived β cells. Stem Cell Rep. 12, 351–365. https://doi.org/10.1016/j.stemcr.2018.12.012 (2019).
Acknowledgements
This study was supported in part by the grants from the Mayo Clinic Center for Regenerative Medicine, J.W. Kieckhefer Foundation, Al Nahyan Foundation, Regenerative Medicine Minnesota (RMM 101617 TR 004) and NIH (DK107255). Additional support was provided by an NIH Grant EB021911 to HB.
Author information
Authors and Affiliations
Contributions
P.F., A.R. and A.R. designed the experiments; P.F., A.R., K.G., A.M.G, C.D.D. and M.Q.S. performed the experiments; J.W. and H.B. performed computational fluid dynamics simulations; P.F., G.S., Q.P.P. and A. R. analyzed the data; P.F. and A.R. wrote the manuscript with input from all authors.
Corresponding author
Ethics declarations
Competing interests
The authors declare no competing interests.
Additional information
Publisher's note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Supplementary Information
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Fattahi, P., Rahimian, A., Slama, M.Q. et al. Core–shell hydrogel microcapsules enable formation of human pluripotent stem cell spheroids and their cultivation in a stirred bioreactor. Sci Rep 11, 7177 (2021). https://doi.org/10.1038/s41598-021-85786-2
Received:
Accepted:
Published:
DOI: https://doi.org/10.1038/s41598-021-85786-2
- Springer Nature Limited
This article is cited by
-
Designing magnetic microcapsules for cultivation and differentiation of stem cell spheroids
Microsystems & Nanoengineering (2024)
-
Dextran sulfate prevents excess aggregation of human pluripotent stem cells in 3D culture by inhibiting ICAM1 expression coupled with down-regulating E-cadherin through activating the Wnt signaling pathway
Stem Cell Research & Therapy (2022)
-
In vitro proliferation and long-term preservation of functional primary rat hepatocytes in cell fibers
Scientific Reports (2022)
-
Regulating the Oil-Water Interface to Construct Double Emulsions: Current Understanding and Their Biomedical Applications
Chemical Research in Chinese Universities (2022)