Abstract
To investigate the mechanism of the release of renin we have isolated the juxtaglomerular apparatus and recorded changes in renin secretion in response to various stimuli. To separate and concentrate the juxtaglomerular apparatus we isolated glomeruli and incubated them in a defined medium. The glomeruli were then tested for pressor activity. Clearly, if such a preparation had a characteristic secretion pattern for renin, then we would have a concentration of viable juxtaglomerular apparatus ready for in vitro studies. This communication summarizes our results and the unexpected finding that glomeruli produce a pressor substance distinct from renin.
Similar content being viewed by others
References
Lowry, O. H., Rosebrough, N. J., Farr, A. L., and Randall, R. J., Biol. Chem., 193, 265 (1961).
Arakawa, K., and Nakamura, M., Circulation Res., 21 (Suppl. II), 101 (1968).
Bumpus, F. M., Trans. NY Acad. Sci., 27, 445 (1965).
Skeggs, L. T., Kahn, J. R., and Shumway, N. P., J. Exp. Med., 103, 295 (1956).
Martin, E., Scheideger, J. J., Grabar, P., and Williams, C. A., Bull. Schwiz. Akad. Med. Wiss., 10, 193 (1954).
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
FINKIELMAN, S., NAHMOD, V. In vitro Production of Angiotensin I by Renal Glomeruli. Nature 222, 1186–1188 (1969). https://doi.org/10.1038/2221186a0
Received:
Revised:
Issue Date:
DOI: https://doi.org/10.1038/2221186a0
- Springer Nature Limited