Skip to main content
Log in

Effect of Water Vapour on the Sensitivity of a Flame Ionization Detector for Gas Chromatography

  • Letter
  • Published:

From Nature

View current issue Submit your manuscript

Abstract

IN a previous communication1, we showed that the sensitivity of a macro-argon detector for gas chromatography is quite markedly affected by the presence of water vapour in the carrier gas stream of argon entering the detector. It was shown that a change in the water-vapour concentration in the argon carrier gas-stream from 8 to 10 p.p.m. v/v reduced the sensitivity of the detector to a constant level of 5.8 p.p.m. v/v of di-ethyl ether vapour by some 20 per cent. It is commonly stated that the sensitivity of a flame ionization detector is little affected by the presence of water vapour2,3, but no quantitative data are given. Entiknap4 reports that the sensitivity of a flame-ionization detector to alcohols was between three and six times as high for aqueous solutions of alcohol as for pure alcohol, when alcohol samples were placed on the chromatographic column. In order to be able to use the flame ionization detector as a standard with which to compare the performance of other detectors, it was necessary to have quantitative data on the effect of water vapour on the sensitivity of this detector.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Hill, D. W., and Newell, H. A., Nature, 205, 593 (1965).

    Article  ADS  CAS  Google Scholar 

  2. Condon, R. D., Scholly, P. R., and Averill, W., in Gas Chromatography 1960, edit. by Scott, R. P. W., 30 (Butterworths, London, 1960).

    Google Scholar 

  3. Lovelock, J. E., Anal. Chem., 33, 162 (1961).

    Article  CAS  Google Scholar 

  4. Entiknap, J. B., in Alcohol and Road Traffic, 238 (Brit. Med. Assoc., London, 1963).

    Google Scholar 

  5. Butler, R. A., and Hill, D. W., Nature, 189, 488 (1961).

    Article  ADS  CAS  Google Scholar 

  6. Crawshaw, J. K., and Davidson, H. G., J. Sci. Instrum., 36, 121 (1959).

    Article  ADS  CAS  Google Scholar 

  7. Wright, B. M., in Alcohol and Road Traffic, 251 (Brit. Med. Assoc., London, 1963).

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

HILL, D., NEWELL, H. Effect of Water Vapour on the Sensitivity of a Flame Ionization Detector for Gas Chromatography. Nature 206, 708–709 (1965). https://doi.org/10.1038/206708a0

Download citation

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1038/206708a0

  • Springer Nature Limited

This article is cited by

Navigation