Skip to main content
Log in

Purification of Raw Surface Water Using Electro-Coagulation Method

  • Published:
Water, Air, and Soil Pollution Aims and scope Submit manuscript

Abstract

The purification of raw surface water from its organic, inorganic and microbial content using the electro-coagulation method was investigated. Batch coagulation experiments were conducted using the jar-test method. A pair of aluminum electrodes (suspended in the jar) was charged with low voltage current for releasing aluminum ions in the raw water to precipitate the suspended matter. The optimum current density was 0.6325 mA cm−2. The coagulation efficiency was evaluated by determining the turbidity of treated water. The efficiency reduction in raw water turbidity was 90%, leading to a change in water Zeta potential from −85 mV (before treatment) to −40 mV (after treatment), i.e. the particles tended to be destabilized and the coagulation process became predominant. Water contents of nitrates, phosphates and sulfates were considerably reduced by 77.5, 83.3 and 20.0%, respectively. Also, this method is effective in reducing both the total viable bacterial count (TVBC) and total coliforms (TC) by a ratio of 1/104 and 1/103, respectively.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Abuzaid, N. S., Bukhari, A. A. and AlHamouz, Z. M.: 1998, 'Removal of bentonite causing turbidity by electro-coagulation', J. Environ. Sci. Health Part A Environ. Sci. Eng. 3, 1341–1358.

    Google Scholar 

  • American Water Works Association: 1995, Introduction of Water Treatment,vol. 2, AWWA, Denver, Colorado, 339 pp.

    Google Scholar 

  • Buffle, J. and De Vitre, R. R.: 1993, Chemical and Biological Regulation of Aquatic Systems,Lewis Publishers, 40 pp.

  • Chen, X., Chen, G. and Yue, P. L.: 2000. 'Separation of pollutants from restaurant waste water by electro-coagulation', Separat. Purif. Technol. 9, 65–69.

    Google Scholar 

  • Clark, J. A., Burger, C. A. and Sabatinos, L. E.: 1982, 'Characterization of indicator bacteria in municipal raw water, drinking water, and new main supplies', Can. J. Microbiol. 8, 1002–1013.

    Google Scholar 

  • Duan, J. and Gregory, J.: 2003, 'Coagulation by hydrolyzing metal salt', Adv. Col. Interf. Sci. 2, 50–475

    Google Scholar 

  • Eaton, A. D., Clesceri, L. S. and Greemberg, C. G.: 1995, Standard Method for the Examination of Water and Wastewater, 19th ed., American Public Health Association, USA.

    Google Scholar 

  • Edzwald, J. K., Bottero, J. Y., Ives, K. J. and Klute, R.: 1997, 'Particle alteration and particle production processes' in J. B. Mc Ewan (ed.), Treatment Process Selection for Particle Removal,AWWA, IWSA, New York, pp. 73–123.

    Google Scholar 

  • Faust, S. D. and Aly, O. M.: 1983, Chemistry of Water Treatment, Butterworth Publishers, USA.

    Google Scholar 

  • Franceschi, M., Girou, A., Carro-Diaz, A. M., Maurette, M. T. and Puech-Costes, E.: 2002, 'Opti-misation of the coagulation-flocculation process of raw water by optimal design method', Water Res. 6(14): 3561–3572.

    Google Scholar 

  • Giese, R. F. and Van Oss, C. J.: 2002, Colloid and Surface Properties of Clays and Related Minerals, Marcel Dekker/Interscience, New York, 312 pp.

    Google Scholar 

  • Hammer, M. J.: 1986, Water and Waste Water Treatment, 2nd ed., Wiley, New York.

    Google Scholar 

  • Haas, C. N.: 1999, 'Disinfection', in R.D. Letterman (ed.), Water Quality and Treatment, 5th ed., AWWA, McGraw-Hill, NY, pp. 14.1–14.49.

    Google Scholar 

  • Hassouna, M. S., EL-Masry, M. H., EL-Rakchy, N. and Mousa, I.: 1994, 'Effects of chlorination, clarification and sand filtration on the bacterial content of raw water', Tanta Med.J. 2, 1479–1491.

    Google Scholar 

  • Hofkes, E. H.: 1983, Small Community Water Supplies: Technology of Small Water Supply in Devel-oping Countries,Wiley, New York.

    Google Scholar 

  • Hunter, R.: 1981, Zeta Potential in Colloid Science, Academic Press, London, New York.

    Google Scholar 

  • Jiang, J., Graham, N., André, C., Kelsall, G. H. and Brandon, N.: 2002, 'Laboratory study of electro-coagulation-flotation for water treatment', Water Res. 6, 4064–4078.

    Google Scholar 

  • Lu, X., Chen, Z. and Yang, X.: 1999, 'Spectroscopic study of aluminum specification in removing humic substances by Al-coagulation', Water Res. 3, 3271–3280

    Google Scholar 

  • Mattesn, M. J., Dobson, R. L., Glenn, R. W., Kukunoor, N. S., Waits, W. H. and Clayfield, E. J.: 1995, 'Electro-coagulation and separation of aqueous suspensions of ultrafine particles', Coll. Surf. Part A Physicochem. Eng. Aspects 4, 101–109.

    Google Scholar 

  • Mills, D.: 2000, 'A new process for electrocoagulation', J. Am. Water Works Assoc. 2, 34–38.

    Google Scholar 

  • Payment, P., Trudel, M. and Plante, R.: 1985, 'Elimination of viruses and indicator bacteria at each step of treatment during the preparation of drinking water at seven water treatment plants', Appl. Environ. Microbiol. 9, 1418–1428.

    Google Scholar 

  • Shi, B. and Tang, H.: 1999, 'Study on the electrical charge and coagulation behavior of poly-aluminum chloride-organic polymer composite flocculates', Huanjing Huaxue 8, 302–308.

    Google Scholar 

  • Theraja, B. L.: 1999, A Text Book of Electrical Technology in IS Units, 17th ed., S. Chand & Co. Ltd., New Delhi.

    Google Scholar 

  • USEPA.: 1990, Technologies for Upgrading existing or Designing New Drinking Water Treatment Facilities, U.S. Environmental Protection Agency, Cincinnati, 159 pp.

  • Wiesner, M. R. and Klute, R.: 1997, 'Properties and measurements of particulate contaminants in water', in J. B. Mcewen (ed.), Treatment Process Selection for Particle Removal,AWWA, IWSA, NY, pp. 35–72.

    Google Scholar 

  • WHO, 1995, Guidelines for Drinking Water Quality. WHO Office, Geneva.

  • Yamada, T.: 1999, 'Water purifying filter material and water purification method by using the material', Jpn. Kokai Tokkyo Koho JP 11 221,588 [99 221,588] (Cl. C02F3/10),17August 1999, Appl. 1998/24,250, 5 February 1998, 10 pp.

  • Zeta-Meter Inc.: 1968, Zeta-Meter Manual, 2nd ed., Zeta-Meter Inc., New York.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Mohamed H. El-Masry.

Rights and permissions

Reprints and permissions

About this article

Cite this article

El-Masry, M.H., Sadek, O.M. & Mekhemer, W.K. Purification of Raw Surface Water Using Electro-Coagulation Method. Water, Air, & Soil Pollution 158, 373–385 (2004). https://doi.org/10.1023/B:WATE.0000044857.02199.45

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1023/B:WATE.0000044857.02199.45

Navigation