Abstract
Mathematical relations between the multiplicative instrumental component of the measurement error in a tested parameter and the level of uctuations of characteristics of an electronic channel are obtained for certain forms of amplitude distributions and conditions of selecting pulses from a detector. It is shown theoretically that the instrumental error plays an important role in choosing the main and optimum parameters of the measurement tools, in particular, under increased detector loadings. Practical methods of taking into account and reducing significantly the instrumental error for particular situations are given with reference to the use of SBM-20 counters in gamma-absorption densimeters.
Similar content being viewed by others
References
Gol'din, M.L., Teoreticheskie osnovy izmeritel'noi tekhniki fotonnogo izlucheniya (Theoretical Foundations of Measuring Instrumentation of Photon Radiation), Moscow: Energoatomizdat, 1985.
Kokhov, E.D., Mil'chakov, V.I., and Shchekin, K.I., Effect of the Instability of Instrumentation on the Accuracy of X-Ray-Radiometric Analysis, In: Radiatsionnaya tekhnika (X-Ray Equipment), vol. 10, Moscow: Atomizdat, 1974, pp. 210-217.
Novitskii, P.V. and Zograf, I.A., Otsenka pogreshnostei resul'tatov izmerenii (Estimation of Measurement Errors), Moscow: Energoatomizdat, 1991.
Gorbunov, V.I., Pekarskii, G.Sh., and Bezuglov, A.I., Quasi-Albedo (Neutron-Gamma Type) Technique for Thickness Meters of Single-Layer Steel Products and Optimization of Its Parameters, Defektoskopiya, 1979, no. 12, pp. 80-84.
GOST (State Standard) 8.368-79. Plotnomery radioizotopnye zhidkikh sred i pul'p. Metody i sredstva poverki (Radioisotopic Densimeters for Liquid Media and Pulps. Calibration Methods and Tools).
Hudson, D., Statistics for Physicists. Translated into Russian under the title Statistika dlya fizikov, Moscow: Mir, 1970.
GOST (State Standard) 20180-74. Plotnomery radioizotopnye zhidkikh sred i pul'p. Obshchie tekhnicheskie trebovaniya (Radioisotopic Densimeters for Liquid Media and Pulps. General Technical Requirements).
Gol'danskii, V.I., Kutsenko, A.V., and Podgoretskii, M.P., Statistika otschetov pri registratsii yadernykh chastits (Counting Statistics in Recording Nuclear Particles), Moscow: Fizmatgiz, 1959.
Shamsholin, A.N., Kolesov, B.M., Ganichev, G.I. et al., Increasing the Operating Speed of a Counting Channel with Halogenous Gamma-Quantum and Beta-Particle Counters, Pribory i Tekhnika Eksperimenta, 1973, no. 1, pp. 65-66.
SBM-19, SBM-20. Nizkovol'tnye schetchiki Geigera-Mullera zhestkogo beta-i gamma-izlucheniya. Pasport (SBM-19 and SBM-20. Low-Voltage Geiger-Muller Counters for High-Energy Beta-and Gamma-Rays. Certificate), OOO “Albedo” Factory, 2000.
Komp'yuterizovannaya stantsiya nazemnogo kontrolya protsessa tsementirovaniya neftegazopromyslovykh skvazhin KSKTs-01 (KSKTs-01 computerized station of ground testing of the process of cementing oil-gas production wells), Promotional Materials of the Introscopy Research Institute of the Tomsk Polytechnical University, Russian, Tomsk, 2001, Internet site: http://inri.tpu.ru
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Bezuglov, A.I. Effect of the Multiplicative Instrumental Error on X-Ray Measuring Instrument Characteristics. Russian Journal of Nondestructive Testing 39, 782–790 (2003). https://doi.org/10.1023/B:RUNT.0000020250.75093.3e
Issue Date:
DOI: https://doi.org/10.1023/B:RUNT.0000020250.75093.3e