An improved construction of the UKh-2 level meter is described, in which a new sensor inductance coil circuit is employed, which enables the unmeasurable layer of liquid at the bottom of the container to be reduced. The main constructional features and electric circuit of the level meter are given, and its fundamental technical characteristics are presented.
Similar content being viewed by others
REFERENCES
F. I. Mamedov et al., Khim. Promyshl., No. 4, 56 (1984).
N. F. Gakhramanov et al., Prib. Sist., Upravl., Kontr., Diagnost., No. 12, 57 (2001).
Rights and permissions
About this article
Cite this article
Gakhramanov, N.F., Adygezalov, V.S., Dzhamilov, R.S. et al. Modernization of the UKh-2 Chlorine Level Meters. Measurement Techniques 46, 876–879 (2003). https://doi.org/10.1023/B:METE.0000008448.74068.d1
Issue Date: