Skip to main content
Log in

Statistical analysis of measured actinide concentration bias in a Mixed Analyte Performance Evaluation Program

  • Published:
Journal of Radioanalytical and Nuclear Chemistry Aims and scope Submit manuscript

Abstract

Data from seven Mixed Analyte Performance Evaluation Program studies have been used to identify specific problems with results and/or laboratories. These data have never been used to determine the bias or variability in data reporting for these laboratories in general. These historical analytical data were analyzed for accuracy and precision overall and separated by method of sample preparation, method of sample pretreatment, method of detection and sample size. The calculated mean percent relative bias was analyzed for the actinides (241Am, 238Pu, 239/240Pu, 234/233U, and 238U) in the soil and water standards. Results from most analysis methods were at least slightly negatively biased. For the water standards, the overall 95% confidence interval for the mean percent relative bias was −1.6% to −0.5% indicating that the average actinide results slightly underestimated the true concentration. For the soil standards, the overall 95% confidence interval for the mean percent relative bias was −8.1% to −6.6% indicating that the average actinide results moderately underestimated the true concentration.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. P. S. Horn, P. W. Britton, D. F. Lewis, The Statistician, 37 (1988) 165.

  2. K. Kafadar, J. Amer. Statistical Assoc., 77 (1982) 378; 416.

    Article  Google Scholar 

  3. P. W. Britton, D. F. Lewis, USEPA Quality Assurance Branch, Environmental Monitoring and Support Laboratory, Cincinnati, June 9, 1986.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Leecaster, M.K., Dahlgran, J.R. Statistical analysis of measured actinide concentration bias in a Mixed Analyte Performance Evaluation Program. Journal of Radioanalytical and Nuclear Chemistry 261, 577–586 (2004). https://doi.org/10.1023/B:JRNC.0000037098.43990.81

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1023/B:JRNC.0000037098.43990.81

Keywords

Navigation