Abstract
Objective. Closed-loop mechanical ventilation has the potential to provide more effective ventilatory support to patients with less complexity than conventional ventilation. The purpose of this study was to investigate the effectiveness of an automatic technique for mechanical ventilation. Methods. Two closed-loop control systems for mechanical ventilation are combined in this study. In one of the control systems several physiological data are used to automatically adjust the frequency and tidal volume of breaths of a patient. This method, which is patented under US Patent number 4986268, uses the criterion of minimal respiratory work rate to provide the patient with a natural pattern of breathing. The inputs to the system include data representing CO2 and O2 levels of the patient as well as respiratory compliance and airway resistance. The I:E ratio is adjusted on the basis of the respiratory time constant to allow for effective emptying of the lungs in expiration and to avoid intrinsic positive end expiratory pressure (PEEP). This system is combined with another closed-loop control system for automatic adjustment of the inspired fraction of oxygen of the patient. This controller uses the feedback of arterial oxygen saturation of the patient and combines a rapid stepwise control procedure with a proportional-integral-derivative (PID) control algorithm to automatically adjust the oxygen concentration in the patient's inspired gas. The dual closed-loop control system has been examined by using mechanical lung studies, computer simulations and animal experiments. Results. In the mechanical lung studies, the ventilation controller adjusted the breathing frequency and tidal volume in a clinically appropriate manner in response to changes in respiratory mechanics. The results of computer simulations and animal studies under induced disturbances showed that blood gases were returned to the normal physiologic range in less than 25 s by the control system. In the animal experiments under steady-state conditions, the maximum standard deviations of arterial oxygen saturation and the end-tidal partial pressure of CO2 were ± 1.76% and ± 1.78 mmHg, respectively. Conclusion. The controller maintained the arterial blood gases within normal limits under steady-state conditions and the transient response of the system was robust under various disturbances. The results of the study have showed that the proposed dual closed-loop technique has effectively controlled mechanical ventilation under different test conditions.
Article PDF
Similar content being viewed by others
REFERENCES
Saxton GA, Jr, Myers GH. A servomechanism for automatic regulation of pulmonary ventilation. J Appl Physiol 1957; 11: 326–328.
Frumin MJ, Bergman NA, Holaday DA. Carbon dioxide and oxygen blood levels with a carbon dioxide controlled artificial respirator. Anesthesiology 1959; 20(3): 313–321.
Mitamura Y, Mikami T, Sugawara H, Yoshimoto C. An optimally controlled respirator. IEEE Trans Biomed Eng 1971; BME-18: 330–337.
Coles JR, Brown WA, Lampard DG. Computer control of ventilation and anesthesia. Med Biol Eng 1973; 11: 262–267.
Mitamura Y, Mikami T, Yamamoto K, Mimura K. A dual control system for assisting respiration. Med Biol Eng 1975; 13(6): 846–854.
Coon RL, Zuperku EJ, Kampine JP. Systemic arterial blood pH servo control of mechanical ventilation. Anesthesiology 1978; 49(3): 201–204.
Ohlson KB, Westenskow DR, Jordan WS. A microprocessor based feedback controller for mechanical ventilation. Ann Biomed Eng 1982; 10: 35–48.
Chapman FW, Newell JC, Roy RJ. A feedback controller for ventilatory therapy. Ann Biomed Eng 1985; 13: 359–372.
Ritchie RG, Ernst EA, Pate BL, Pearson JP, Sheppard LC. Closed-loop control of an anesthesia delivery system: Development and animal testing. IEEE Trans Biomed Eng 1978; BME-34(6): 437–443.
Tehrani FT. Method and apparatus for controlling an artificial respirator. U.S. Patent No. 4986268, 22nd January 1991.
Laubscher TP, Heinrichs W, Weiler N, Hartmann G, Brunner JX. An adaptive lung ventilation controller. IEEE Trans Biomed Eng 1994; 41(1): 51–59.
Schaublin J, Derighetti M, Feigenwinter P, Petersen-Felix S, Zbinden AM. Fuzzy logic control of mechanical ventilation during anesthesia. Br J Anesth 1996; 77: 636–641.
Fernando T, Cade J, Packer J. Automatic control of arterial carbon dioxide tension in mechanically ventilated patients. IEEE Trans Info Tech Biomed 2002; 6(4): 269–276.
Otis AB, Fenn WO, Rahn H. Mechanics of breathing in man. J Appl Physiol 1950; 2: 592–607.
Beddis IR, Collins P, Levy NM, Godfrey S, Silverman M. New technique for servo-control of arterial oxygen tension in preterm infants. Arch Dis Child 1979; 54: 278–280.
Sano A, Kikucki M. Adaptive control of arterial oxygen pressure of newborn infants under incubator oxygen treatments. Proc IEE 1985; 132(Part D., No. 5): 205–211.
Yu C, He WG, So JM, Roy R, Kaufman H, Newell JC. Improvement in arterial oxygen control usingmultiple model adaptive control procedures. IEEE Trans Biomed Eng 1987; BME-34(8): 567–574.
Morozoff PE, Evans RW. Closed loop control of \(S_{aO_2}\) in the neonate. Biomed Instr Tech 1992; 26: 117–123.
Tehrani FT. A microcomputer oxygen control system for ventilatory therapy. Ann Biomed Eng 1992; 20(5): 547–558.
Tehrani FT, Bazar AR. A feedback controller for supplemental oxygen treatment of newborn infants: A simulation study. Med Eng Phys 1994; 16: 329–333.
Raemer DB, Ji X, Topulos GP. FIX controller: An instrument to automatically adjust inspired oxygen fraction using feedback control from a pulse oximeter. J Clin Monit 1997; 13: 91–101.
Tehrani FT. A control system for oxygen therapy of premature infants. Proc IEEE Eng Med Biol Conf 2001; 23(2): 2059–2062.
Tehrani FT, Rogers M, Lo T, Malinowski T, Afuwape S, Lum M, Grundl B, Terry M. Closed-loop control of the inspired fraction of oxygen in mechanical ventilation. J Clin Monit Comput 2002; 17(6): 367–376.
Visser BF. Pulmonary diffusion of carbon dioxide. Phys Med Biol 1961; 5: 155–166.
Riley RL. Gas exchange and transportation. In: Ruch TC, Patton HD, eds. Physiology and biophysics. Philadelphia and London: Saunders, 1966: 761–787.
Gray JS. Pulmonary ventilation and its physiological regulation. Springfield, Illinois: Charles C. Thomas, 1949.
Fincham WF, Tehrani FT. A mathematical model of the human respiratory system. J Biomed Eng 1983; 5: 125–133.
Tehrani FT. Mathematical analysis and computer simulation of the respiratory system in the newborn infant. IEEE Trans Biomed Eng 1993; 40(5): 475–481.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Tehrani, F., Rogers, M., Lo, T. et al. A Dual Closed-Loop Control System for Mechanical Ventilation. J Clin Monit Comput 18, 111–129 (2004). https://doi.org/10.1023/B:JOCM.0000032744.99885.38
Issue Date:
DOI: https://doi.org/10.1023/B:JOCM.0000032744.99885.38