Abstract
Background: A circadian variation exists for ventricular defibrillation thresholds (DFTs) with a morning peak and a corresponding decrease in therapy success rates from implantable cardioverter defibrillators. Such a variation in atrial DFTs may have implications for the timing of internal cardioversion of atrial arrhythmias. The aim of this study was therefore to determine the circadian variation of atrial DFTs in patents with recurrent atrial fibrillation (AF).
Methods and results: Data were collected as part of the worldwide Jewel AF-only study. Patients had recurrent persistent AF and no history of ventricular arrhythmias. The atrial DFT was assessed at device implantation using a step-up protocol and was recorded for 100 patients (age 63.0 ± 11.7, 74% male, ejection fraction 49.6 ± 17.8%, left atrial diameter 46 ± 9 mm). The mean atrial DFT was 6.3 ± 4.3 J. For the most commonly tested lead configuration (right atrium to coronary sinus in 56 patients), the atrial DFT for patients implanted in the morning (3.3 ± 1.5 J) was significantly lower than for both the DFT measured in the afternoon (5.8 ± 3.4 J, p < 0.01) and the DFT measured in the evening (7.4 ± 5.9 J, p < 0.01).
Conclusion: There may be a significant variation in measured atrial DFT for the right atrium to coronary sinus configuration, with a nadir in the morning. This is the converse to measurements of ventricular DFTs suggesting different regulatory electrophysiological mechanisms. Further investigation of this possible variation is warranted.
Similar content being viewed by others
References
Gold MR, Sulke N, Schwartzman D, Mehra R, Euler DE, Worldwide Jewel AF-Only Investigatiors. Clinical experience with a dual-chamber implantable cardioverter defibrillator to treat atrial tachyarrhythmias. J Cardiovasc Electrophysiol 2001;12(11):1247-1253.
Schoels W, Swerdlow CD, Jung W, Stein KM, Seidl K, Haffajee CJ, Worldwide Jewel AF-Only Investigatiors. Worldwide clinical experience with a new dual-chamber implantable cardioverter defibrillator system. J Cardiovasc Electrophysiol 2001;12(5):521-528.
Venditti FJ, Jr., John RM, Hull M, Tofler GH, Shahian DM, Martin DT. Circadian variation in defibrillation energy requirements. Circulation 1996;94(7):1607-1612.
Muller JE, Stone PH, Turi ZG, Rutherford JD, Czeisler CA, Parker C, Poole WK, Passamani E, Roberts R, Robertson T, MILIS Study Group. Circadian variation in the frequency of onset of acute myocardial infarction. N Engl J Med 1985;313(21):1315-1322.
D'Avila A, Wellens F, Andries E, Brugada P. At what time are implantable defibrillator shocks delivered? Evidence for individual circadian variance in sudden cardiac death. Eur Heart J 1995;16(9):1231-1233.
Muller JE, Ludmer PL, Willich SN, Tofler GH, Aylmer G, Klangos I, Stone PH. Circadian variation in the frequency of sudden cardiac death. Circulation 1987;75(1):131-138.
Peckova M, Fahrenbruch CE, Cobb LA, Hallstrom AP. Circadian variations in the occurrence of cardiac arrests: Initial and repeat episodes. Circulation 1998;98(1):31-39.
Mitchell AR, Spurrell PA, Kamalvand K, Higson M, Shanmuganathan R, Patel NR, Sulke N. What is the optimal electrode configuration for atrial defibrillators in man? Europace 2002;4(1):41-44.
Boriani G, Biffi M, Capucci A, Bronzetti G, Ayers GM, Zannoli R, Branzi A, Magnani B. Favorable effects of flecainide in transvenous internal cardioversion of atrial fibrillation. J Am Coll Cardiol 1999;33(2):333-341.
Boriani G, Biffi M, Camanini C, Bacchi L, Zannoli R, Luceri R, Branzi A. Predictors of atrial defibrillation threshold in internal cardioversion. Pacing Clin Electrophysiol 2000;23(11 Pt 2):1898-1901.
Cinca J, Moya A, Bardaji A, Rius J, Soler-Soler J. Circadian variations of electrical properties of the heart. Ann NY Acad Sci 1990;601:222-233.
Hohnloser SH, Klingenheben T. Insights into the pathogenesis of sudden cardiac death from analysis of circadian fluctuations of potential triggering factors. Pacing Clin Electrophysiol 1994;17(3 Pt 2):428-433.
Zimmermann M, Kalusche D. Fluctuation of autonomic tone is a major determinant of sustained atrial arrhythmias in patients with focal ectopy originating from the pulmonary veins. J Interv Card Electrophysiol 2001;12(3):285-291.
Wen ZC, Chen SA, Tai CT, Huang JL, Chang MS. Role of autonomic tone in facilitating spontaneous onset of typical atrial flutter. J Am Coll Cardiol 1998;31(3):602-607.
Huang JL, Wen ZC, Lee WL, Chang MS, Chen SA. Changes of autonomic tone before the onset of paroxysmal atrial fibrillation. Int J Cardiol 1998;66(3):275-283.
Pietrucha A, Matysek J, Piwowarska W, Mroczek-Czernecka D, Gackowski A, Stobierska B, Nessler J, Musialek P, Dziafkowick A. Analysis of circadian distribution of premature ventricular contractions in patients after heart transplantation. Pacing Clin Electrophysiol 1994;17(11 Pt 2):2064-2067.
Linsell CR, Lightman SL, Mullen PE, Brown MJ, Causon RC. Circadian rhythms of epinephrine and norepinephrine in man. J Clin Endocrinol Metab 1985;60(6):1210-1215.
Ruffy R, Schechtman K, Monje E. Beta-adrenergic modulation of direct defibrillation energy in anesthetized dog heart. Am J Physiol 1985;248(5 Pt 2):H674-H677.
Sousa J, Kou W, Calkins H, Rosenheck S, Kadish A, Morady F. Effect of epinephrine on the efficacy of the internal cardioverter-defibrillator. Am J Cardiol 1992;69(5):509-512.
Barold HS, Shander G, Tomassoni G, Simons GR, Wharton JM. Effect of increased parasympathetic and sympathetic tone on internal atrial defibrillation thresholds in humans. Pacing Clin Electrophysiol 1999;22(1 Pt 2):238-242.
Steinhaus DM, Cardinal DS, Mongeon L, Musley SK, Foley L, Corrigan S. Internal defibrillation: Pain perception of low energy shocks. Pacing Clin Electrophysiol 2002;25(7):1090-1093.
Harbinson MT, Allen JD, Imam Z, Dempsey G, Anderson JM, Ayers GM, Adgey AA. Rounded biphasic waveform reduces energy requirements for transvenous catheter cardioversion of atrial fibrillation and flutter. Pacing Clin Electrophysiol 1997;20(1 Pt 2):226-229.
Kidwai BJ, Allen JD, Harbinson MT, McIntyre A, Anderson J, Adgey AA. Waveform optimization for internal atrial defibrillation: Effects of waveform rounding, phase duration, and voltage swing. Pacing Clin Electrophysiol 2001;24(8 Pt 1):1198-1207.
Murgatroyd FD, Slade AK, Sopher SM, Rowland E, Ward DE, Camm AJ. Efficacy and tolerability of transvenous low energy cardioversion of paroxysmal atrial fibrillation in humans. J Am Coll Cardiol 1995;25(6):1347-1353.
Ammer R, Alt E, Ayers G, Lehmann G, Schmitt C, Pasquantonio J, Putter K, Schmidt M, Schomig A. Pain threshold for low energy intracardiac cardioversion of atrial fibrillation with low or no sedation. Pacing Clin Electrophysiol 1997;20(1 Pt 2):230-236.
Everett TH, Li H, Mangrum JM, Mastrangelo C, Haines DE. The effects of atrial electrical remodeling on atrial defibrillation thresholds. Pacing Clin Electrophysiol 2001;24(8 Pt 1):1208-1215.
Mangrum JM, Everett TH, Mitchell MA, McRury ID, Li H, Haines DE. The effects of reverse atrial electrical remodeling on atrial defibrillation thresholds. Pacing Clin Electrophysiol 2002;25(4 Pt 1):470-476.
Boriani G, Bartolini P, Biffi M, Calcagnini C, Corazza I, Zannoli R, Barbaro V, Branzi A. Atrial signal analysis and defibrillation threshold assessment in chronic persistent and reinduced atrial fibrillation. J Cardiovasc Electrophysiol 2002;13(5):449-454.
Mitchell AR, Spurrell PA, Sulke AN. The circadian variation of arrhythmia onset patterns in patients with persistent atrial fibrillation. Am Heart J 2003;146(5):902-907.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Mitchell, A.R.J., Warman, E., Schaaf, K. et al. The Circadian Variation of Atrial Defibrillation Thresholds. J Interv Card Electrophysiol 10, 79–83 (2004). https://doi.org/10.1023/B:JICE.0000011489.99159.25
Issue Date: