Abstract
A nonlinear approach is presented to simulate the coaxial-waveguide cyclotron autoresonance maser (CARM) amplifier. Simulation shows an interesting result that the efficiency of a coaxial-waveguide CARM amplifier may be increased from 7.5% to 33.9% by tapering the magnetic field.
Similar content being viewed by others
References
M. I. Petelin, Radiophys. Quantum Electron. 17, 686(1974).
V. L. Bratman, G. G. Denisov, B. D. Kol'chugin, S. V. Samsonov, and A. B. Volkov, Phys. Rev. Lett. 75, 3102(1995).
G. G. Denisov, V. L. Bratman, A. W. Cross, W. He, A. d. R. Phelps, et al., Phys. Rev. Lett. 81, 5680(1998).
S.-C. Zhang, A coaxial-waveguide cyclotron autoresonance maser amplifier (to be published)
B. Piosczyk, O. Braz, G. Dammertz, C. T. Iatrou, S. Kern, M. Kuntz, A. Mobius, M. Thumm, V. A. Flyagin, V. I. Khishnyak, V. I. Malygin, A. B. Pavelyev, and V. E. Zapevalov, IEEE Trans. Plasma Sci. 25, 460(1997).
Q.S. Wang, IEEE Trans. Plasms Sci. 20, 163(1992).
S.-C. Zhang, W.-Y. Wang, and Y. Xu, Acta Physica Sinica 42, 762(1993).
S.-C. Zhang, Introduction to Free-Electron Lasers (SWJTU Publishing House, Chengdu in China, 1993).
S.-C. Zhang, Phys. Rev. A46, 5154(1992).
C. Chen and J. S. Wurtele, Phys. Rev. Lett. 65, 3389(1990).
W. L. Menninger, B. G. Danly, C. Chen, K. D. Pendergast, and R. J. Temkin, Particle Accelerator Conference, 1991, Accelerator Science and Tech, Conf. Record of the 1991 IEEE, vol.2, 754(1991).
C. Chen and J. S. Wurtele, Phys. Rev. A40, 489(1989).
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Qiu, CR., Zhang, SC. & Zhang, HB. Nonlinear Investigation of a Coaxial-Waveguide Cyclotron Autoresonance Maser Amplifier. International Journal of Infrared and Millimeter Waves 25, 451–458 (2004). https://doi.org/10.1023/B:IJIM.0000019312.56522.a0