Skip to main content
Log in

Should Smoke Yield be Regulated for Wall, Ceiling and Floor Linings?

  • Published:
Fire Technology Aims and scope Submit manuscript

Abstract

A major issue in fire safety engineering is the control and regulation of smoke production from wall linings. When a material burns it produces smoke. Smoke production has two attributes, its volume and its concentration. The smoke volume is the total amount of smoke per unit time, and is proportional to the heat release rate. The smoke concentration depends on the smoke yield of the material, which is defined as grams of smoke produced per gram of material burnt. Current two-zone models, generally accepted in fire safety design, determine whether tenability conditions are met based on smoke volume. In these models a distinct interface between the smoke and the clear layer is assumed. This paper focuses on the impact of smoke yield on tenability. Two issues are discussed (a) the variation of smoke yield with ventilation conditions and (b) the influence of smoke density gradients between the smoke and clear layer on tenability conditions. Two examples are presented to illustrate the significance of these issues.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Australian Building Codes Board, “Building Code of Australia, Sydney,” Australia, CCH Australia Ltd., 1996.

    Google Scholar 

  2. J.M. Blackmore and M.A. Delichatsios, “Fire Performance of Floors and Wall Coverings,” FCRC, Project 2B, December 1999.

  3. J. Blackmore and M.A. Delichatsios, “Flammability Tests for Assessing Carpet Performance,” Journal of Fire Protection Engineering, vol. 12, no. 1, 2002, pp. 45–59.

    Google Scholar 

  4. A. Tewarson, “Generation of Heat and Chemical Compounds in Fires,” SFPE Handbook of Fire Protection Engineering, 1995, pp. 3-53.

  5. J. Tomman, “Comparison of Nordtest FIRE 007, CEN Draft Proposal (Radiant Pane) and Cone Calorimeter in the Fire Testing of Floor Coverings,” Fire and Materials, vol. 17, 1993, pp. 185–190.

    Google Scholar 

  6. M. Hischler, “Smoke and Heat Release Rate and ignitability as measures of Fire Hazard from Burning Carpet Tiles,” Fire Safety J., vol. 18, 1992, pp. 305–324.

    Google Scholar 

  7. CBUF, “Fire Safety of Upholstered Furniture,” Final Report, EUR 16477 EN, 1995, pp. 134-140.

  8. ASTM E1354, “Standard Test Method for Heat and Visible Smoke Release Rates for Materials and Products Using an Oxygen Consumption Calorimeter,” American Society for Testing and Materials, 1999.

  9. ISO 9705, International Standard, Fire Tests-Full Scale Room Test for Surface Products, 1st edn., Reference Number ISO/TC92/WG7/N124, 1993.

  10. ASTM E648-97, “Standard Test Method for Critical Radiant Flux of Floor-Covering Systems Using a Radiant Heat Energy Source,” American Society for Testing and Materials, March 1997.

  11. I.A. Benjamin and C.H. Adams, “Proposed Criteria for Use of the Critical Radiant Flux Test Method,” NBSIR, 1975, pp. 75-950.

  12. N. McArthur and C.B. Jolliffe, “Development of a Demountable Fire Test Corridor for Assessment of Floor Coverings,” in Fire Safety Science-Proceedings of the Fifth International Symposium, IAFSS, 1997.

  13. Fire Code Reform Center, Fire Engineering Guidelines, 1st edn., March 1996.

  14. W.W. Jones, G.P. Forney, R.D. Peacock, and A. Reneke, “Technical Reference for CFAST: An Engineering Tool for Estimating Fire and Smoke Transport,” NIST TN 1431, 2000.

  15. B. Karlsson and J.G. Quintiere, Enclosure Fire Dynamics, CRC Press, Washington, DC, 1999.

    Google Scholar 

  16. M.A. Delichatsios, “Flame Heights in Turbulent Wall Fires with Significant Flame Radiation,” Combustion Science and Technology, vol. 39, 1984, p. 195.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Delichatsios, M.A., Blackmore, J. & Liu, X. Should Smoke Yield be Regulated for Wall, Ceiling and Floor Linings?. Fire Technology 40, 263–276 (2004). https://doi.org/10.1023/B:FIRE.0000026880.92848.73

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1023/B:FIRE.0000026880.92848.73

Navigation