Abstract
A new version of immunoenzyme assay for the antigens of pathogenic microorganisms Streptococcus pyogenes and Staphylococcus aureus based on the use of amperometric sensors is proposed for their determination in diagnosing infectious diseases (tonsillitis of different severities). The best conditions for sensor operation were chosen, and the quantitative characteristics of the antibodies used and the antigen–antibody immune complexes formed. The sensors developed were tested with blood serums from ill patients, and the possibility of the differential diagnostics of diseases, at the early stages of their development, in particular, was demonstrated.
Similar content being viewed by others
REFERENCES
Beletskaya, L.V., Verbolovich, P.A., and Polosukhina, T.Ya., Eksperimental'naya streptokokkovaya infektsiya (Experimental Streptococcic Infection), Alma-Ata: Nauka, 1978.
Swaminathan, B. and Feng, P., Annu. Rev. Microbiol., 1994, vol. 48, p. 401.
Vel'tishchev, Yu.E., Komarov, F.I., Navashin, S.M., et al., Spravochnik prakticheskogo vracha (A Guide of a General Practitioner), Moscow: Meditsina, 1992, vol. 2.
Cush, R., Cronin, J.M., Stewart, W.J., Maule, C.H., Molloy, J., and Goddard, N.J., Biosens. Bioelectron., 1993, vol. 8, p. 347.
Watts, H.J., Lowe, C.R., and Pollard-Knight, D.V., Anal. Chem., 1994, vol. 66, p. 2465.
Ivnitski, D., Abdel-Hamid, I., Atanasov, P., and Wilkins, E., Biosens. Bioelectron., 1999, vol. 14, p. 599.
Bao, L., Deng, L., Nie, L., Yao, S., and Wei, W., Anal. Chim. Acta, 1996, vol. 319, p. 97.
Brooks, J.L., Mirhabibollahi, B., and Kroll, R.G., J. Appl. Bacteriol., 1992, vol. 73, p. 189.
Rishpon, J. and Ivnitski, D., Biosens. Bioelectron., 1997, vol. 12, no. 3, p. 195.
Endo, H., Fujisaki, K., Ohkubo, Y., Hayashi, T., and Watanabe, E., Fish. Sci., 1996, vol. 62, p. 235.
Khaldeeva, E.V., Medyantseva, E.P., Glushko, N.I., and Budnikov, G.K., Analitika Kontrol, 2001, vol. 5, no. 1, p. 47.
Medyantseva, E.P., Babkina, S.S., Vertlib, M.G., and Budnikov, G.K., Zh. Anal. Khim., 1993, vol. 48, no. 10, p. 1632.
Medyantseva, E.P., Li, Fa-Shen', Fedoseeva, O.V., Budnikov, G.K., Skrodelis, O.E., and Zeidaka, A.A., Zh. Prikl. Biokhim. Mikrobiol., 1993, vol. 29, no. 4, p. 619.
Budnikov, G.K., Medyantseva, E.P., Volkov, A.V., and Aronzon, S.S., Zh. Anal. Khim., 1983, vol. 38, no. 7, p. 1283.
Plambeck, J., Electroanalytical Chemistry: Basic Principles and Applications, New York: Wiley, 1982. Translated under the title Elektrokhimicheskie metody analiza: Osnovy teorii i primenenie, Moscow: Mir, 1985, p. 387.
Fernandez-Sanchez, C., Gonzalez-Garcia, M.B., and Costa-Garcia, A., Biosens. Bioelectron., 2000, vol. 14, no. 12, p. 917.
Teoriya i praktika immunofermentnogo analiza (Theory and Practice of Immunoassay Analysis), Egorov, A.M., Ed., Moscow: Vysshaya Shkola, 1991.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Medyantseva, E.P., Safina, G.R., Khaldeeva, E.V. et al. Application of Amperometric Immunoenzyme Sensors to the Determination of Bacterial Antigens. Journal of Analytical Chemistry 59, 168–174 (2004). https://doi.org/10.1023/B:JANC.0000014746.01726.3d
Issue Date: