Skip to main content
Log in

Processing of Whole Femoral Head Allografts: A Method for Improving Clinical Efficacy and Safety

  • Published:
Cell and Tissue Banking Aims and scope Submit manuscript

Abstract

Femoral heads removed during primary hip replacement surgery are widely utilised as a source of allograft bone. Despite evidence that processing these grafts to remove blood and marrow elements improves both the clinical performance and safety of these allografts, many are transplanted without any processing being applied at all. The goal of this study was to investigate the efficiency of an allograft processing protocol which incorporates pasteurisation, (3 h, 56–60°C) centrifugation, (1850g, 2 × 15 min, 40°C) sonication, and repeated washing in warm (56–60°C, 19 h) distilled, sterile water to remove blood and marrow elements from the graft. The protocol also involves applying heat treatment to the grafts which has been demonstrated to inactivate many pathogenic viruses. Following the processing procedure, the grafts are lyophilised and sterilised with ethylene oxide gas. The amount and rate of removal of 4 different components of blood and marrow from 6 whole femoral head allografts were measured. These were lipid, soluble protein, elastase and chloride ions. Lipid removal was assessed gravimetrically by solvent extraction of dried samples, soluble protein by the Bradford assay, elastase by radioimmunoassay and choride ion content by a modified commercially available colorimetric assay. Removing lipid from grafts has been shown to increase the rate of incorporation when the graft is used clinically. Elastase was studied as a marker of leukocyte removal, as evidence suggests the majority of potentially infective transmissible spongiform encephalopathy (TSE) activity resides in a sub-population of leukocytes. Soluble protein was studied as a marker of plasma removal, as a smaller amount of TSE infectivity resides here. Chloride removal was measured as this is a necessary pre-requisite to terminal sterilisation with ethylene oxide. The results showed that the protocol removed 74.5% (range: 68.0–90.8) of the lipid content, 96.4% (range: 94.8–98.4) of the soluble protein content, 97.7% (range: 97.1–100) of the elastase content and 98.8% (range: 98.0–99.2) of the chloride ion content. We have shown that processing designed to improve the clinical efficiency and safety of bone allografts can be accomplished without compromising the structural and biological properties of the graft.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Aspenberg P and Lindqvist SB (1998) Ethylene oxide and bone induction: controversy remains. Acta Orthop Scand 69(2): 173-176

    Google Scholar 

  • Borchers RE, Gibson LJ, Burchardt H and Hayes WC (1995) Effects of selected thermal variables on the mechanical properties of trabecular bone. Biomaterials 16(7): 545-551

    Google Scholar 

  • Bradford MM (1976) A rapid and sensitive method for the quantification of microgram quantities of protein utilising the principle of protein dye binding. Anal Biochem 72: 248-256

    Google Scholar 

  • Brown P, Rohwer RG, Dunstan BC, MacAuley C, Gajdusek DC and Drohan WN (1998) The distribution of infectivity in blood components and plasma derivatives in experimental models of transmissible spongiform encephalopathy. Transfusion 38: 810-816

    Google Scholar 

  • Chappard D, Fressonet C, Genty C, Basle MC and Rebel A (1993) Fat in bone xenografts: importance of purification procedures on cleanliness, wettability and biocompatibility. Biomaterials 14: 507-511

    Google Scholar 

  • Christensen EA and Kristensen H (1992) Gaseous sterilisation. In: Russell AD, Hugo WB and Aycliffe GAJ (eds) Principles and Practice of Disinfection and Sterilisation. Blackwell Science, Oxford, 2nd edition.

    Google Scholar 

  • Fages J, Marty A, Delga C, Condoret JS, Combes D and Frayssinet P (1994) Use of supercritical CO2 for bone delipidation. Biomaterials 15(9): 650-656

    Google Scholar 

  • Fideler BM, Vangsness CT, Moore T, Li Z and Rasheed S (1994) Effects of gamma irradiation on the human immunodeficiency virus. JBJS 76-A: 1032-1035

    Google Scholar 

  • Gie GA, Linder L, Ling RS, Simon JP, Sloof TJ and Timperley AJ (1993) Contained morselized allograft in revision total hip arthroplasty. Surgical technique. Orthop Clin North Am 24(4): 717-725

    Google Scholar 

  • Gillan H (1999) Annual survey of the issue of skeletal tissues 1996-1998. British Association of Tissue Banks Newsletter No. 11: 9-10

  • Greer IA, Haddad NG, Dawes J, Johnstone FD and Calder AA (1989) Neutrophil activation in pregnancy induced hypertension. British Journal of Obstetrics and Gynaecology 96: 978-982

    Google Scholar 

  • Hallfeldt KK, Stutzle H, Puhlmann M, Kessler S and Schweiberer L (1995) Sterilisation of partially demineralised bone matrix: the effects of different sterilisation techniques on osteogenic properties. J Surg Res 59(5): 614-620

    Google Scholar 

  • Hiemstra H, Tersmette M, Vos AH, Over J, Van Berkel MP and De Bree H (1991) Inactivation of HIV by gamma irradiation and its effect on plasma and coagulation factors. Transfusion 31: 32-39

    Google Scholar 

  • Kearney JN and Lomas RJ (1997) The osteoinductive properties of demineralised bone matrix grafts. In Phillips GO (ed) Advances in Tissue Banking, Vol 1, pp 43-73, World Scientific, Singapore

    Google Scholar 

  • Kearney JN, Bojar R and Holland KT (1993) Ethylene oxide sterilisation of allogeneic bone implants. Clinical Materials 12: 129-135

    Google Scholar 

  • Klein M, Frigg R, Suter M, Zinkernagel RM and Aguzzi A (1997) A crucial role for B cells in neuroinvasive scrapie. Nature 390: 687

    Google Scholar 

  • Moreau MF, Gallois Y, Basle MF and Chappard D (2000) Gamma irradiation of human bone allografts alters medullary lipids and releases toxic compounds for osteoblast-like cells. Biomaterials 21(4): 369-376

    Google Scholar 

  • Nowak T, Niedrig M, Bernhardt D and Hilfenhaus J (1993) Inactivation of HIV, HBV, HCV related viruses and other viruses in human plasma derivatives by pasteurisation. Dev Biol Stand 81: 169-176

    Google Scholar 

  • Prolo DJ, Pedrotti PW, Burres KP and Oklund S (1982) Superior osteogenesis in transplanted allogeneic canine skull following chemical sterilisation. Clin Orthop 168: 230-242

    Google Scholar 

  • Pruss A, Kao M, Kiesewetter H, von Versen R and Paull G (1999) Virus safety of avital bone tissue transplants: evaluation of sterilisation steps of spongiosa cuboids using a peracetic acid-methanol mixture. Biologicals 27: 195-201

    Google Scholar 

  • Rock MG (1991) Biomechanics of allografts. In: Czitrom AA and Winkler H (eds) Orthopaedic Allograft Surgery. Springer Wien, New York, pp 29-37

    Google Scholar 

  • Taylor DM, Fraser H, McConnell I, Brown DA, Brown KL, Lamza KA and Smith GR (1994) Decontamination studies with the agents of bovine spongiform encephalopathy and scrapie. Arch Virol 139: 313-326

    Google Scholar 

  • Thadani V, Penar PL, Partington J, Kalb R, Janssen R, Schonberger LB, Rabkin CS and Prichard JW (1988) Creutzfeld-Jakob disease probably aquired from a cadaveric dura mater graft. Case report. J Neurosurg 69(5): 766-769

    Google Scholar 

  • Thoren K and Aspenberg P (1995) Ethylene oxide impairs allograft incorporation in a conduction chamber. Clin Orthop 318: 259-264

    Google Scholar 

  • Thoren K, Aspenberg P and Thorngren KG (1995) Lipid extracted bank bone: bone conductive and mechanical properties. Clin Orthop 311: 232-246

    Google Scholar 

  • Urist MR (1965) Bone formation by autoinduction. Science 150: 893-899

    Google Scholar 

  • Urist MR and Iwata H (1973) Preservation and biodegredation of the morphogenetic property of bone matrix. J Theor Biol 38: 155-167

    Google Scholar 

  • Voggenreiter G, Ascherl R, Fruh HJ, Blumel G and Schmit-Neuerberg KP (1995) Preservation and sterilization of cortical bone-biomechanical studies in the rat. Unfallchirurg 98(2): 53-58

    Google Scholar 

  • Zhang Q, Cornu O and Delloye C (1997) Ethylene oxide does not extinguish the osteoinductive capacity of demineralised bone. A reappraisal in rats. Acta Orthop Scand 68(2): 104-108

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Lomas, R., Drummond, O. & Kearney, J. Processing of Whole Femoral Head Allografts: A Method for Improving Clinical Efficacy and Safety. Cell Tissue Banking 1, 193–200 (2000). https://doi.org/10.1023/A:1026512312385

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1023/A:1026512312385

Navigation