Abstract
The aim of this study was to determine the concentration of trace elements present in Sarıkamış ore by the standard addition method. The elements determined were Ca, Ti, Fe, Sr, Ba. The equipment used for this study was a Si(Li)-detector, a multichannel analyzer and 55Fe and 241Am radioisotope sources. The physical basis of the analytical method used, the procedure of sample preparation and the results are presented.
Similar content being viewed by others
References
A. Karabulut, G. Budak, Spectrochim. Acta, B55 (2000) 91.
G. Budak, A. Karabulut, Spectrochim. Acta, B54 (1999) 985.
D. Mihajlovic, T. Stafilov, X-Ray Spectrom., 27 (1998) 397.
T. H. Nguyen, J. Boman, M. Leermakers, W. Baeyens, X-Ray Spectrom., 27 (1998) 277.
P. L. Leung, Z. C. Peng, M. J. Stokes, M. T. W. Li, X-Ray Spectrom., 29 (2000) 253.
A. Somogyi, M. Braun, Toth, K. J. Willis, X-Ray Spectrom., 27 (1998) 283.
R. Cesareo, A. Castellano, G. Buccolieri, M. Marabelli, Nucl. Instr. Meth., B155 (1999) 326.
M. M. Al-Kofahi, K. F. Al-Tarawneh, J. M. Shobaki, X-ray Spectrom., 26 (1997) 10.
R. E. Van Grieken, A. A. Markowicz, Handbook of X-Ray Spectrometry, 1992, Chapter 5.9, p. 314.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Ekinci, N., Gürol, A., Polat, R. et al. The qualitative and quantitative analysis of Sarıkamış ore by energy dispersive X-ray fluorescence. Journal of Radioanalytical and Nuclear Chemistry 258, 163–165 (2003). https://doi.org/10.1023/A:1026234815188