Skip to main content
Log in

Is the k0 method accurate for elements with high Q0 values?

  • Published:
Journal of Radioanalytical and Nuclear Chemistry Aims and scope Submit manuscript

Abstract

With a SLOWPOKE reactor, activation by epithermal neutrons is more important than for most other reactors. It was therefore undertaken to verify the accuracy of the k 0 method for all elements with high Q 0 values. Accurate standards of 40 elements were prepared and irradiated in the inner and outer irradiation sites of the Ecole Polytechnique SLOWPOKE reactor and then counted 10 cm from a 29% germanium detector and the amount of element in each case was calculated from the gamma-ray spectrum using the k 0 method. For 13 nuclides with high Q 0 values the results differed from the expected amounts by more than 5%, which suggests that measurements of new k 0 and Q 0 values are needed.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. G. Kennedy, J. St-Pierre, K. Wang, Y. Zhang, J. Preston, C. Grant, M. Vutchkov, J. Radioanal. Nucl. Chem., 245 (2000) 167.

    Google Scholar 

  2. F. De Corte, A. Simonits, A. De Wispelaere, J. Hoste, J. Radioanal. Nucl. Chem., 113 (1987) 145.

    Google Scholar 

  3. A. Simonits, F. De Corte, S. Van Lierde, S. Pomme, P. Robouch, M. Eguskiza, J. Radioanal. Nucl. Chem., 245 (2000) 199.

    Google Scholar 

  4. F. De Corte, K. Sordo-El Hammami, L. Moens, A. Simonits, A. De Wispelaere, J. Hoste, J. Radioanal. Chem., 62 (1981) 209.

    Google Scholar 

  5. J. St-Pierre, G. Kennedy, Biol. Trace Elem. Res., 71 (1999) 481.

    Google Scholar 

  6. G. Kennedy, J. St-Pierre, J. Radioanal. Nucl. Chem., 215 (1997) 235.

    Google Scholar 

  7. R. Van Sluijs, D. Bossus, M. Blaauw, G. Kennedy, A. De Wispelaere, S. Van Lierde, F. De Corte, J. Radioanal. Nucl. Chem., 244 (2000) 675.

    Google Scholar 

  8. F. De Corte, A. Simonits, J. Radioanal. Nucl. Chem., 133 (1989) 43.

    Google Scholar 

  9. F. De Corte, A. Simonits, F. Bellemans, M. C. Freitas, S. Jovanovic, B. Smodis, G. Erdtmann, H. Petri, A. De Wispelaere, J. Radioanal. Nucl. Chem., 169 (1993) 125.

    Google Scholar 

  10. F. De Corte, J. Radioanal. Nucl. Chem., 234 (1998) 9.

    Google Scholar 

  11. B. Smodis, F. De Corte, A. De Wispelaere, J. Radioanal. Nucl. Chem., 186 (1994) 183.

    Google Scholar 

  12. S. Van Lierde, F. De Corte, D. Bossus, R. Van Sluijs, S. Pomme, Nucl. Instr. Meth. Phys. Res., A422 (1999) 874.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Kennedy, G., St-Pierre, J. Is the k0 method accurate for elements with high Q0 values?. Journal of Radioanalytical and Nuclear Chemistry 257, 475–480 (2003). https://doi.org/10.1023/A:1025411825372

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1023/A:1025411825372

Keywords

Navigation