The potentialities of videoendoscopic isolation and extravasal occlusion of large vessels with titanium clips were studied in acute and chronic experiments on 36 animals and anatomic studies on 5 human cadavers. The number and optimal sites for insertion of trocars and disposition of instruments and thoracoscope for isolation of open ductus arteriosus were determined. A method for videoendoscopic isolation of vessels is developed and possible complications and measures for their liquidation evaluated. High efficiency and low traumatism of videoendoscopic operation are proven under condition of strict adherence to methodology and sufficient qualification of the surgeon in endosurgical manipulations.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

REFERENCES

  1. I. Borini, P. Dalmonte, G. Cervo, et al., G. Ital. Cardiol., 27,No. 8, 786–789 (1997).

    Google Scholar 

  2. R. P. Burke, J. P. Jacobs, W. Cheng, and G. P. Fontana, Pediatrics, 104,No. 2, Pt. 1, 227–230 (1999).

    Google Scholar 

  3. M. N. Hines, A. S. Bensky, J. W. Hammon Jr., and D. G. Pennington, Ann. Thorac. Surg., 66,No. 3, 853–858 (1998).

    Google Scholar 

  4. F. Laborde, T. Folliquet, A. Batisse, et al., Arch. Mal. Coeur Vaiss., 89,No. 5, 547–551 (1996).

    Google Scholar 

  5. J. Lavoie, F. A. Burrows, T. L. Gentles, et al., Can J. Anaesth., 41,No. 4, 310–313 (1994).

    Google Scholar 

  6. T. Maera, K. Kokaji, Y. Yamachita, et al., Rinsho Kyobu Geka, 14,No. 1, 13–17 (1994).

    Google Scholar 

  7. O. Oto, E. Hasan, U. Acikel, et al., J. Cardiovasc. Surg. (Torino), 39,No. 3, 379–381 (1998).

    Google Scholar 

  8. S. S. Rothenberg, J. H. Chang, W. H. Joews, and R. L. Washington, J. Pediatr. Surg., 30,No. 7, 1057–1060 (1995).

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Vasilenko, Y.V., Kim, A.I. & Kotov, S.A. Experimental Validation of Videoendoscopic Isolation and Occlusion of the Bloodflow in Open Ductus Arteriosus. Bulletin of Experimental Biology and Medicine 135, 308–310 (2003). https://doi.org/10.1023/A:1024161704082

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1023/A:1024161704082

Navigation