Abstract
This study evaluates the effect of rhBMP-7/OP-1 on the osseointegration of commercially pure titanium implants in an experimental implant model in rabbits. Threaded titanium implants with two transverse parallel canals were inserted in the femur and tibia of rabbits. The canals were filled with, 10 μg of BMP-7/collagen carrier, pure collagen carrier or were left empty as a control. The stiffness of the implant fixation was evaluated by Resonance Frequency Analysis (RFA) at baseline and four weeks postoperativly. Percentage of bone ingrowth in the canals was measured on microradiographs. Histomorphometry along the threaded part of the implants was performed on 15 μm thin sections. The results from the RFA demonstrated a higher mean value for the BMP-7 treated implants in the tibia than the carrier treated implants but not compared to the control implants. The control implants in the tibia demonstrated more bone ingrowth in the upper canal than to the carrier or the BMP-7 treated implants. Apart from these differences there were no significant effects of BMP. In this study BMP-7 did not contribute to any substantially improved bone anchorage of titanium implants.
Similar content being viewed by others
References
T. Albrektsson, P.-I. Brånemark, H.-A. Hansson and J. Lindström, Acta Orthop. Scand. 52 (1981) 155.
M. Urist, R. De Lange and G. Finerman, Science 220 (1983) 680.
J. Wozney, V. Rosen, M. Byrne, A. Celeste and I. Moutsatsos, J. Cell. Sci. 13s (1990) 149.
S. Mohan and D. Baylink, Clin. Orthop. Rel. Res. 263 (1991) 30.
M. Urist, Science 150 (1965) 893.
E. Wang, V. Rosen, P. Cordes, R. Hewick, M. Kriz, B. Sibley, D. Luxenburg and J. Wozney, Proc. Natl. Acad. Sci. USA 85 (1988) 9484.
J. Wozney, V. Rosen, A. Celeste, L. Mitsock, M. Whitters, Kriz, R. Hewick and E. Wang, Science 242 (1988) 28.
A. Celeste, J. Ianuzzi, R. Taylor, R. Hewick, V. Rosen and J. Wozney, Pro. Natl. Acad. Sci. USA 87 (1990) 9843.
J. D'Allesandro, J. Bone Min. Res. 6 (1991) S153 (abstract).
J. Wozney, Mol. Reprod. Develop. 32 (1992) 160.
M. Murata, M. Inoue, H. Nagatsuka, H. Konouchi, C. H. Qin, S.-Q. Zhang, M. Mizuno, Y. Kuboki, T. Takagi and N. Nagai, J. Hard Tissue Biol. 3 (1994) 67.
Y. Yamazaki, S.-I. Oida, K. Ishihara and N. Nakabayashi, J. Biomed. Mat. Res. 30 (1996) 1.
K. Yoshida, K. Bessho, K. Fujimura, Y. Ogawa, Y. Tani and T. Iizuka, J. Cranio-Maxillofac. Surg. 26 (1998) 112.
D. Zegzula, D. Buck, J. Brekke, J. Wozney and J. Hollinger, J. Bone and Joint Surg. 79-A (1997) 1788.
J. Teixiera and M. Urist, Arch. Orthop. Trauma Surg. 117 (1998) 27.
G. Zellin and A. Linde, Scand. J. Plast. Hand Surg. 31 (1997) 97.
S. Cook, J. Dalton, E. Tan, T. Whiteclou and D. Reuger, Spine 19 (1994) 1655.
T. Sigurdsson, D. Tatakis, M. Rohrer and U. Wikesjö, Clin. Oral. Impl. Res. 8 (1997) 367.
C. Jeppsson and P. Aspenberg, Acta Orthop. Scand. 67 (1996) 589.
C. Jeppsson, M. Boström and P. Aspenberg, ibid. 70 (1999) 77.
O. Hanisch, D. Tatakis, M. Rohrer, P. Wohrle, J. Wozney and U. Wikesjö, Int. J. Oral Maxillofac. Implants 12 (1997) 785.
S. Cook, S. Salkeld and D. Reuger, J. Oral Implantology 21 (1995) 281.
T. Albrektsson, M. Jacobsson and P. Kälebo, Adv. in Biomat. (1983) 283.
D. Kaigler and B. Lang, In. J. Oral Maxillofac. Implants 4 (1989) 183.
N. Meredith, PhD Thesis, Dept of Biomaterials/Handicap research, Göteborg University, Sweden (1997).
K. Donath, Preparation of histologic sections by cutting-grinding technique for hard tissue and other materials not suitable to be sectioned by routine methods. Norderstedt: EXAKT-Kulzer-Publication (1993) p. 1.
B. Klinge, C. Johansson, H. Hallström and T. Engdal, Clin. Oral Impl. Res. 6 (1995) 91.
C. B. Johansson, PhD Thesis, Dept. of Biomaterials/Handicap Research, Göteborg University, Sweden (1991).
M. Bostrom, P. Aspenberg, C. Jeppsson and E. Salvati, Clin. Orthop. Rel. Res. 350 (1998) 221.
K. Bessho, D. Carnes, R. Cavin, H.-Y. Chen and J. Ong, Clin. Oral Impl. Res. 10 (1999) 212.
B. Rutherford, K. Sampath, D. Reuger and T. Taylor, Int. J. Oral Maxillofac. Implants 7 (1992) 297.
W. Xiang, L. Baulin, J. Yan and X. Yang, J. Oral Maxillofac. Surg. 51 (1993) 647.
J. Yan, W. Xiang, L. Baolin and F. White, Maxillofac. Prosth. Dent. Impl. 71 (1994) 289.
D. Cochran, P. Nummikoski, A. Jones, S. Makins, T. Turek and D. Buser, Int. J. Oral Maxillofac. Implants 12 (1997) 739.
O. Hanisch, D. Tatakis, M. Boskovic, D. Rohrer and U. Wikesjö, ibid. 12 (1997) 604.
E. Hedner and A. Linde, Eur. J. Oral Sci. 103 (1995) 236.
S. Cook, S. Salked and D. Reuger, J. Oral Implantology 21 (1995) 281.
V. Franke Stenport, B. Olsson, P. Morberg, J. Törnell and C. Johansson, Clin. Impl. Dent. Rel. Res. 4 (2001) 135.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Stenport, V.F., Johansson, C., Heo, S.J. et al. Titanium implants and BMP-7 in bone: an experimental model in the rabbit. Journal of Materials Science: Materials in Medicine 14, 247–254 (2003). https://doi.org/10.1023/A:1022884724059
Issue Date:
DOI: https://doi.org/10.1023/A:1022884724059