Skip to main content
Log in

Normal Spectral Emissivity of Niobium (at 900 nm) by a Pulse-Heating Reflectometric Technique

  • Published:
International Journal of Thermophysics Aims and scope Submit manuscript

Abstract

The normal spectral emissivity of niobium strip specimens was measured using a new pulse-heating reflectometric technique. The hemispherical spectral reflectivity of the surface of a strip tangent to an integrating sphere is determined by a high-speed lock-in technique. At the same time, the radiance temperature of the strip is measured by high-speed pyrometry from approximately 1000K to the melting point. Details of the measurement method and of the related calibration techniques are reported. Results of the normal spectral emissivity of niobium at 900 nm from room temperature to its melting point are presented, discussing differences related to the heating rate and to surface conditions.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

REFERENCES

  1. F. Righini, G. C. Bussolino, and A. Rosso, in Proceedings of TEMPMEKO'06, P. Marcarino, ed. (Levrotto & Bella, Torino, 1997), pp. 489–492.

    Google Scholar 

  2. A. Cezairliyan, S. Krishnan, and J. L. McClure, Int. J. Thermophys. 17:1455 (1996).

    Google Scholar 

  3. F. Righini, A. Rosso, and A. Cibrario, High Temp.-High Press. 17:153 (1985).

    Google Scholar 

  4. F. Righini, G. C. Bussolino, A. Rosso, and J. Spišiak, Int. J. Thermophys. 14:485 (1993).

    Google Scholar 

  5. A. Cezairliyan, A. P. Miiller, F. Righini, and A. Rosso, in Temperature. Its Measurement and Control in Science and Industry, Vol. 6, J. F. Schooley, ed. (American Institute of Physics, New York, 1992), pp. 377–382.

    Google Scholar 

  6. F. Righini, G. C. Bussolino, A. Rosso, and J. Spišiak, Int. J. Thermophys. 14:495 (1993).

    Google Scholar 

  7. A. Cezairliyan, High Temp.-High Press. 4:453 (1972).

    Google Scholar 

  8. F. Righini, J. Spišiak, G. C. Bussolino, and M. Gualano, Int. J. Thermophys. 20:1107 (1999).

    Google Scholar 

  9. F. Righini, R. B. Roberts, and A. Rosso, Int. J. Thermophys. 6:681 (1985).

    Google Scholar 

  10. H. Preston-Thomas, Metrologia 27:3 (1990).

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Righini, F., Spišiak, J. & Bussolino, G.C. Normal Spectral Emissivity of Niobium (at 900 nm) by a Pulse-Heating Reflectometric Technique. International Journal of Thermophysics 20, 1095–1106 (1999). https://doi.org/10.1023/A:1022602820071

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1023/A:1022602820071

Navigation