Abstract
By the use of Fabry–Perot resonator with quality factor ≃ 600 000 and fast precision (down to one Hertz) frequency control of coherent millimeterwave radiation source the 20 Hz accuracy in measurements of the width of resonance curve is obtained. This accuracy corresponds to the detection of 1.8 × 10−3 dB/km absorption in the sample filling the resonator and exceeds the before known sensitivity more than by an order of magnitude. The example of precise measurement of 60 GHz oxygen absorption band in the real atmosphere is presented. The new possibilities of application of precision resonator microwave spectroscopy to the atmospheric problems as well as to the ultra-low absorptions measurements in dielectrics and metal surfaces up to Terahertz frequencies are discussed.
Similar content being viewed by others
References
C.H. Townes, A.L. Shawlow, Microwave Spectroscopy, Dover, N.Y, (1975).
A.F. Krupnov, V.V. Parshin, G. Yu. Golubyatnikov, I.I. Leonov, Yu.N. Konoplev, IEEE Trans. on Microwave Theory Tech, 47, 284–289 (1999).
H.J. Liebe, Int. J. Infrared and Millimeter Waves, 10, 631–635 (1989); H.J. Liebe, P.W. Rosenkranz, G.A. Hufford, J. Quant. Spectr. Radiat. Transfer, 48, 629–638 (1992).
4. M.B. Golant, R.L. Vilenskaya, E.A. Zyulina, Z.F. Kaplun, A.A. Negirev, V.A. Parilov, E.B. Rebrova, V.S. Saveliev, Pribory i Technika Eksperimenta (in Russian; available in English as Sovjet Physics-Pribory) N 4, 136–139 (1965).
5. A.F. Krupnov, Izv. VUZov, Radiofizika (in Russian; available in English as Radiophysics and Electronics), 41, 1361–1374 (1998); A.F. Krupnov, Spectrochimica Acta A, 52, 967–991 (1996).
A.F. Krupnov, O.P. Pavlovsky, Int. J. Infrared and Millimeter Waves, 15, 1611–1624 (1994).
W. Gordy, R.L. Cook, Microwave Molecular Spectra, Interscience (Wiley), N.Y, (1984).
V.V. Parshin, V.G. Ralchenko, V.I. Konov, Proc. 23rd Int. Conf. Infrared Millim. Waves, Colchester, UK, Sept. 7–11 (1998), p. 232.
G. Winnewisser, A.F. Krupnov, M.Yu. Tretyakov, M. Liedtke, F. Lewen, A.H. Saleck, R. Schieder, A.P. Shkaev, S.A. Volokhov, J. Mol. Spectrosc, 165, 294–300 (1994).
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Krupnov, A.F., Tretyakov, M.Y., Parshin, V.V. et al. Precision Resonator Microwave Spectroscopy in Millimeter and Submillimeter Range. International Journal of Infrared and Millimeter Waves 20, 1731–1737 (1999). https://doi.org/10.1023/A:1021797111636
Issue Date: