Skip to main content
Log in

Isotope measurements in uranium using a quadrupole inductively coupled plasma mass spectrometer (ICPMS)

  • Published:
Journal of Radioanalytical and Nuclear Chemistry Aims and scope Submit manuscript

Abstract

A series of measurements were carried out to establish the reliability associated with isotope ratio (235/238) measurements on uranium samples using a quadrupole inductively coupled plasma mass spectrometer (ICPMS). Figures of merit related to the isotopic measurements were determined using non certified as well as certified materials provided by the New Brunswick Laboratory (NBL). The experimental results showed that repeatability is around 0.5% while reproducibility was calculated as 0.27%. Mass discrimination was determined as 0.03% per mass unit and the system linearity check over five orders of isotope ratios yielded a mass discrimination factor (K factor) of 1.0002±0.0081 (0.81%, 2s). The mean error of measurement obtained from six different certified reference materials was 0.77%.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. K. J. R. ROSMAN, P. D. P. TAYLOR, Isotopic Compositions of the Elements 1997, Pure Appl. Chem., IUPAC, 70 (1998) 217.

    Google Scholar 

  2. I. T. PLATZNER, Modern Isotope Ratio Mass Spectrometry, John Wiley and Sons, New York, 1997, p. 359.

    Google Scholar 

  3. A. E. CAMERON, C. M. STEVENS, Mass Spectrometry in Analysis of Essential Nuclear Reactor Materials, C. J. RODDEN (Ed.), New Brunswick Laboratory (NBL), US Atomic Energy Commission, Chapter 13, 1964, p. 140.

  4. A. J. WALDER, in: Modern Isotope Ratio Mass Spectrometry, I. T. PLATZNER (Ed.), John Wiley and Sons, New York, 1997, p. 83.

    Google Scholar 

  5. F. VANHAECKE, L. MOENS, P. D. P. TAYLOR, Use of ICP-MS for isotope ratio measurements, in: Inductively Coupled Plasma Spectrometry and its Applications, S. J. HILL (Ed.), Sheffield Academic Press, 1999, p. 145.

  6. P. D. P. TAYLOR, P. D. BIEVRE, A. J. WALDER, A. ENTWISTLE, J. Anal. At. Spectrom., 10 (1995) 395.

    Google Scholar 

  7. J. A. WALDER, D. KOLLER, N. M. REED, R. C. HUTTON, P. A. FREEDMAN, J. Anal. At. Spectrom., 8 (1993) 1037.

    Google Scholar 

  8. I. T. PLATZNER, Modern Isotope Ratio Mass Spectrometry, John Wiley and Sons, New York, 1997, p. 363.

    Google Scholar 

  9. O. P. OLIVEIRA Jr., Analise multielementar e isotopica em compostos de uranio por espectrometria de massas com fonte de plasma induzido (ICPMS), Master of Sciences, IPEN, Universidade de Sao Paulo, 2000.

  10. The International System of Units, Bureau International des Poids et Mesures (BIPM), 7th ed., France, 1998.

  11. International Vocabulary of Basic and General Terms in Metrology, International Standardization Organization (ISO), 2nd ed., Switzerland, 1993.

  12. Guide to the Expression of Uncertainty in Measurement, International Organization for Standardization (ISO), 2nd ed., Geneve, 1995.

  13. Quantifying Uncertainty in Analytical Measurement, EURACHEM, 2nd ed., 2000.

  14. G. F. KNOLL, Radiation Detection and Measurement, John Wiley and Sons, New York, 1979, p. 119.

    Google Scholar 

  15. G. P. RUSS III, in: Applications of Inductively Coupled Plasma Mass Spectrometry, A. R. DATE and A. L. GRAY (Eds), London, Blackie and Sons Ltd., 1989.

    Google Scholar 

  16. IAEA Safeguards, Statistical Concepts and Techniques, 4th revised ed., International Atomic Energy Agency, Vienna, 1989.

    Google Scholar 

  17. G. P. RUSS III, J. M. BAZAN, Spectrochim. Acta, 42B (1987) 49.

    Google Scholar 

  18. P. D. BIÈVRE, Proc. of the 7th Intern. Mass Spectrometry Conf., Italy, N. R. DALY (Ed.), Heyden and Son Ltd., 1976, p. 412.

  19. I. T. PLATZNER, Modern Isotope Ratio Mass Spectrometry, John Wiley and Sons, New York, 1997, p. 186.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Oliveira, O.P., Sarkis, J.E.S. Isotope measurements in uranium using a quadrupole inductively coupled plasma mass spectrometer (ICPMS). Journal of Radioanalytical and Nuclear Chemistry 253, 345–350 (2002). https://doi.org/10.1023/A:1020444814314

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1023/A:1020444814314

Keywords

Navigation