A new technique used in order to realize fluoride ion-sensitive membranes is presented. This method consists of the ion implantation technique which is highly compatible with integrated circuit (i.c.) technology. This technique can be used for realizing various inorganic membranes for sensing purposes.
In this paper, we studied two thin film membranes based on lanthanum and calcium fluoride compounds for fluoride detection, through the ion implantation technique. The electrical and chemical properties of the films obtained are studied on electrolyte/oxide/semiconductor structures (EOS). The fluoride ion sensitivity is determined using capacitance voltage measurements for the EOS structures. The response obtained is 44 mV per decade in the range of pF- 4 to 2 for LaF3 membrane, and 52 mV per decade in the range of pF- 3 to 1 for CaF2 membranes. Finally, we present data for fluoride sensitive ISFET (ion sensitive field effect transistor) microsensors using the developed CaF2 membrane with a corresponding REFET (reference field effect transistor) in individual and differential mode.
Similar content being viewed by others
References
P. BERGVELD, IEEE Trans. Biomed. Eng. 17 (1970) 70.
J. F. J. ENGBERSEN and D. N. REINHOUDT, Analysis Magazine 22 (1994) 16.
A. A. VASILIEV, D. Y. GODOVSKI, V. N. BEZMELNITSYN and V. S. GAZKOV, Sensors & Actuators B 13 –14 (1993) 649.
F. LABIDI, J. PORTIER, J. SALARDENNE, M. CARRERE, C. QUET, J. P. COUPOT and H. ARRIBART, in Proceedings of 2nd International Meeting on Chemical Sensors, Bordeaux, 7–10 July 1986, edited by J. L. Aucoutrier et al. p. 453.
Y. SANADA, T. AKIYAMA, Y. UJIHIRA and E. NIKI, Fresenius. Z. Anal. Chem. 312 (1982) 526.
Z. M. BACCAR, N. JAFFREZIC-RENAULT, J. M. KRAFT, C. MARTELET, H. JAFFREZIC, G. MAREST and A. PLANTIER, J. Electrochem. Soc. 143 (1996) 1422.
Z. M. BACCAR, N. JAFFREZIC-RENAULT, C. MARTELET, H. JAFFREZIC, G. MAREST and A. PLANTIER, Sensors & Actuators B32 (1996) 101.
Idem., Mater. Chem. Phys., in press.
V. ROCHER, J. M. CHOVELON, N. JAFFREZIC-RENAULT, Y. CROS and D. BIROT, J. Electrochem. Soc. 141 (1994) 535.
J. P. BIERSACK and J. F. ZIEGLER, Trim Program (1992).
J. L. DIOT, J. JOSEPH, J. R. MARTIN and P. CLECHET, J. Electroanal. Chem. 193 (1985) 75.
P. BATAILLARD, PhD. Thesis, Ecole Centrale de Lyon, France (1987).
P. BERGVELD and A. SIBBALD, “Analytical and biomedical applications of sensitive field effect transistor”, Vol. 23 (Wilson & Wilson’s, Amsterdam, The Netherlands, 1988).
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
BACCAR, Z.M., JAFFREZIC-RENAULT, N., MARTELET, C. et al. New fluoride-sensitive membranes prepared through an ion implantation process. Journal of Materials Science 32, 4221–4225 (1997). https://doi.org/10.1023/A:1018690932628
Issue Date:
DOI: https://doi.org/10.1023/A:1018690932628