Skip to main content
Log in

Surface characterization and platelet adhesion studies on polyethylene surface with hirudin immobilization

  • Published:
Journal of Materials Science: Materials in Medicine Aims and scope Submit manuscript

Abstract

Hirudin, a protein composed of 65 or 66 amino acid, is a newly risen anticoagulant agent and has been considered as the most potent thrombin inhibitor. Hirudin can block the active site of thrombin by means of its carboxylic acid reaction with the active regime of thrombin, and becomes a tightly bound complex, and thus controls the formation of thrombus. Hirudin was covalently immobilized onto the water-soluble carbodiimide preactivated and chromic acid oxidized PE surface. Surface chemistry analysis indicated that a certain amount of carboxylic acid groups was generated on the polyethylene surface after oxidation with chromic acid solution. The amount of carboxylic acid functional group increased with the oxidation time. In addition, polyethylene surface was etched by chromic acid solution, and a rougher surface was created. The morphology of oxidized polyethylene surface was similar to each other among the samples with oxidation time from 1 to 8 min. ESCA results indicated the number of hirudin molecules immobilized was constant at the reaction time studied. In vitro platelet adhesion assay indicated the number of adhered platelets on the oxidized polyethylene surface increased significantly after oxidation. In contrast, surface with hirudin immobilization showed a reduction in adhered platelet density than the chromic acid oxidized counterpart due to the decrease of platelet-activating capability by the hirudin–thrombin complex and the differences in the adsorbed protein composition. © 2001 Kluwer Academic Publishers

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. B. Seifer, P. Romaniuk and Th. Groth, Biomaterials 18 (1997) 1495-1502.

    Google Scholar 

  2. F. Markwardt, Thrombosis Research 74 (1991) 1-23.

    Google Scholar 

  3. R. K. Drummond and N. A. Peppas, Biomaterials 12 (1991) 356-360.

    Google Scholar 

  4. G. H. R., S. Park, M. Kim, D. K. Han, Y. Ha Kim and B. Min, Journal of Biomedical Materials Research 28 (1994) 1069-1077.

    Google Scholar 

  5. P. Ollson, H. Lagergren, R. Larsson and K. Radggran, Thrombosis and Haemostasis 37 (1977) 274.

    Google Scholar 

  6. C. J. Delden, G. H. M. Engbers and J. Feijen, Journal of Biomedical Materials Research 29 (1995) 1317-1329.

    Google Scholar 

  7. S. Sano, K. Kato and Y. Ikada, Biomaterials 14 (1993) 817-822.

    Google Scholar 

  8. T.-M. Ko, J.-C. Lin and S. L. Cooper, Journal of Colloid and Interface Science 156 (1993) 207-217.

    Google Scholar 

  9. S. R. Holmes-Farley and G. M. Whitesides, Langmuir 3 (1987) 62-76.

    Google Scholar 

  10. M. D. Phaneuf, S. A. Berceli, M. J. Bide, W. C. Quist and F. W. Logerfo, Biomaterials 18 (1997) 755-765.

    Google Scholar 

  11. C. S. L. Ku, I. Bornstein, J. Breillatt, S. N. Ungchhun, R. Johnson and J. Lindon, Transaction of the 17th Annual Meeting of the Society for Biomaterials 44, 1991.

  12. Y. S. Yeh, Y. Iriyama, Y. Matsuzawa, S.R. Hanson and H. Yasuda, Journal of Biomedical Materials Research 22 (1988) 795-818.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Jui-Che Lin.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Lin, JC., Tseng, SM. Surface characterization and platelet adhesion studies on polyethylene surface with hirudin immobilization. Journal of Materials Science: Materials in Medicine 12, 827–832 (2001). https://doi.org/10.1023/A:1017937304964

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1023/A:1017937304964

Keywords

Navigation