Skip to main content
Log in

Nebulization of Liposomes. II. The Effects of Size and Modeling of Solute Release Profiles

  • Published:
Pharmaceutical Research Aims and scope Submit manuscript

Abstract

A series of carboxyfluorescein (CF)-containing multilamellar vesicle (MLV) dispersions was prepared and extruded through polycarbonate membranes ranging in size from 0.2 to 5 µm. Vesicle dispersions were nebulized for 80 min using a Collison nebulizer, and the release of CF was monitored during nebulization. Solute retention was dependent upon the size of the vesicles and leakage ranged from 7.9 ± 0.4% (N = 3) for vesicles extruded through 0.2-µm filters to 76.8 ± 5.9% (N = 3) for liposomes that were not filtered. Solute release profiles obtained over ≥420-min nebulization periods conformed to a two-compartment kinetic model and exhibited a “fast” initial phase (k l = 0.052 ± 0.0043) followed by a “slow” terminal phase (k 2 = 0.0034 ± 0.00018). The results show that CF retention can be increased by nebulizing small vesicles and modeling suggests that the rate of CF leakage from the bilayers is faster than from the core of the liposomes.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

REFERENCES

  1. R. W. Niven and H. Schreier. Nebulization of liposomes. I. Effects of lipid composition. Pharm. Res. 7:1127–1133 (1990).

    Google Scholar 

  2. B. E. Gilbert, H. R. Six, S. Z. Wilson, P. R. Wyde, and V. Knight. Small particle aerosols of enviroxime-containing liposomes. Antivir. Res. 9:355–365 (1988).

    Google Scholar 

  3. T. T. Mercer, M. I. Tillery, and H. Y. Chow. Operating characteristics of some compressed air nebulizers. Am. Ind. Hyg. Assoc. J. 29:66–78 (1968).

    Google Scholar 

  4. H. W. Young, J. W. Dominik, J. S. Walker, and E. W. Larson. Continuous aerosol therapy system using a modified Collison nebulizer. J. Clin. Microbiol. 5:131–136 (1977).

    Google Scholar 

  5. C. O. Callaghan, A. R. Clarke, and A. D. Milner. Inaccurate calculation of drug output from nebulisers. Eur. J. Pediat. 148:473–474 (1989).

    Google Scholar 

  6. J. A. Wood, R. S. E. Wilson, and C. Bray. Changes in salbutamol concentration in the reservoir solution of a jet nebulizer. Br. J. Dis. Chest 80:164–169 (1986).

    Google Scholar 

  7. K. R. May. The Collison nebulizer: Description, performance and application. J. Aerosol Sci. 4:235–243 (1973).

    Google Scholar 

  8. L. D. Mayer, M. B. Bally, M. J. Hope, and P. R. Cullis. Techniques for encapsulating bioactive agents into liposomes. Chem. Phys. Lipids. 40:333–345 (1986).

    Google Scholar 

  9. S. P. Newman, P. G. D. Pellow, M. M. Clay, and S.W. Clarke. Evaluation of jet nebulizers for use with gentamicin solution. Thorax 40:671–676 (1985).

    Google Scholar 

  10. R. V. Lourenço and E. Cotromanes. Clinical aerosols. I. Characterization of aerosols and their diagnostic uses. Arch. Intern. Med. 142:2163–2172 (1982).

    Google Scholar 

  11. K. M. G. Taylor, G. Taylor, I. W. Kellaway, and J. Stevens. The stability of liposomes to nebulization. Int. J. Pharm. 58:57–61 (1990).

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Niven, R.W., Speer, M. & Schreier, H. Nebulization of Liposomes. II. The Effects of Size and Modeling of Solute Release Profiles. Pharm Res 8, 217–221 (1991). https://doi.org/10.1023/A:1015896121377

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1023/A:1015896121377

Navigation