Abstract
For purposes of optimizing ion-optical systems, analyzer construction, and pump placement in static magnetic mass-spectrometers for isotopic analysis of uranium compounds, a comparative analysis is made and a review is given of methods described in the literature for theoretical estimates of the influence of scattering and reflection of ions on the isotopic sensitivity. Conclusions which make it possible to solve the problem are drawn.
Similar content being viewed by others
REFERENCES
M. Menat, “A quantitative study of scattering phenomena in an electromagnetic separator,” Can. J. Phys., 42, 164–192 (1964).
M. Menat and G. Frieder, “Scattering phenomena in double-direction focusing electromagnetic mass separator,” ibid., 43, 1525–1542 (1965).
D. Ioanviciu, “Elastic scattering phenomena in mass analyzers with tandem fields,” ibid., 48, 1735–1742 (1970).
M. L. Aleksandrov, L. N. Gall', and N. S. Pliss, “Investigation of ion scattering in mass-spectrometers by the statistical simulation method,” Zh. Tekh. Fiz., 44, No. 6, 1302–1305 (1974).
M. P. Aleksandrov, N. S. Pliss, and A. P. Shcherbakov, “Investigation of the influence of reflection of ions from rough surfaces on the formation of the “tails” of peaks in mass spectrometers,” ibid., 47, No. 1, 189–194 (1977).
M. L. Aleksandrov, L. N. Gall', N. S. Pliss, and A. P. Shcherbakov, “Investigation of the scattering of an ion beam on reflection from edges of the diaphragm slits,” ibid., 48, No. 5, 1026–1030 (1978).
M. L. Aleksandrov and N. S. Pliss, “Investigation of the effect of ion scattering and reflection on the isotopic sensitivity of mass spectrometers,” in: Instruments for Scientific Investigations and Automation of an Experiment, Nauka, Mosow (1982), pp. 20–32.
M. L. Aleksandrov, N. S. Plisss, and A. P. Shcherbakov, “Simulation of ion scattering by diatomic molecules,” Zh. Tekh. Fiz., 44, No. 3, 632–634 (1974).
L. M. Gall', “On criteria for optimizing an ion source with electron impact,” ibid., 52, No. 10, 2086–2092 (1982).
L. N. Gall', “On extraction of ions from the ion source of a mass spectrometer,” ibid., 47, No. 10, 2198–2203 (1977).
O. B. Firsov, “Determination of the interatomic forces using the differential elastic scattering cross section,” Zh. Éksp. Teor. Fiz., 24, No. 3, 279–283 (1953).
L. D. Landau and E. M. Livshitz, Mechanics, Fizmatgiz, Moscow (1958), Chap. 4.
V. B. Leonas, “Investigations of short-range intermolecular forces,” Usp. Fiz. Nauk, 107, No. 1, 29–56 (1972).
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Gall', L.N., Latypov, Z.Z. Methods for Estimating Theoretically the Influence of Ion Scattering and Reflection on the Isotopic Sensitivity of Static Magnetic Mass-Spectrometers. Atomic Energy 92, 135–140 (2002). https://doi.org/10.1023/A:1015874605927
Issue Date:
DOI: https://doi.org/10.1023/A:1015874605927