Abstract
The interaction between several marker solutes and a polyolefin laminate polymer was studied in several solutions. Solutions studied included mixtures of sodium chloride and dextrose (at concentrations more less typical of iv administration solutions) and several actual iv products [lactated Ringer's injection, Dianeal, Travasol (amino acid) injection, and alcohol/dextrose injection]. The interaction properties of the candidate container material correlated well with the solute's octanol–water partition coefficient. For nonionic species, the magnitude of the container/solution interaction was independent of solution phase composition. For the ionic test solute, solution pH, which impacts the speciation of the solute, was the only solution composition variable that significantly influenced the interaction. Thus water (or a weak buffer solution) is suggested as an appropriate model solvent for use in container compatibility evaluations involving iv-related products.
Similar content being viewed by others
REFERENCES
D. O. Jordon and A. E. Pollack. The permeation of organic solutes in aqueous solution through polyethylene membranes. II. Effect of concentration, temperature and other variables. Aust. J. Pharm. Sci. NSl:82–87 (1972).
K. Nasim, M. C. Meyer, and J. Autian. Permeation of organic compounds from aqueous solutions through polyethylene. J. Pharm. Sci. 6:1775–1780 (1972).
D. G. Serota, M. C. Meyer, and J. Autian. Effects of structure on permeability of substituted anilines from aqueous solutions through polyethylene. J. Pharm. Sci. 6:416–419 (1972).
C. G. Pitt, Y. T. Bao, A. L. Andrady, and P. N. K. Samuel. The correlation of the polymer-water and octanol-water partition coefficients: Estimation of drug solubilities in polymers. Int. J. Pharm. 45:1–11 (1988).
H. J. Martens, P. N. De Goede, and A. C. Van Loenen. Sorption of various drugs in polyvinyl chloride, glass and polyethylene-lined infusion containers. Am. J. Hosp. Pharm. 47:369–373 (1990).
D. S. Hayward, R. A. Kenley, and D. R. Jenke. Interactions between polymer containers and parenteral solutions: The correlation of equilibrium constants for polymer-water partitioning with octanol-water partition coefficients. Int. J. Pharm. 59:245–253 (1990).
D. S. Hayward, R. A. Kenley, and D. R. Jenke. Evaluation of solute partitioning in polymer/water systems: Application to parenteral container compatibility assessments. Int. J. Pharm. Tech. Prod. Manuf. (in press).
L. Illum and H. Bundgaard. Sorption of drugs by plastic infusion bags. Int. J. Pharm. 10:339–351 (1982).
L. Illum, H. Bundgaard, and S. S. Davis. A constant partition model for examining the sorption of drugs by plastic infusion bags. Int. J. Pharm. 17:183–192 (1983).
E. A. Kowaluk, M. S. Roberts, H. D. Blackburn, and A. E. Polack. Interaction between drugs and polyvinyl chloride infusion bags. Am. J. Hosp. Pharm. 38:1308–1314 (1981).
P. Moorhatch and W. L. Chiou. Interactions between drugs and plastic intravenous fluid bags. i. Sorption studies on 17 drugs. Am. J. Hosp. Pharm. 31:72–78 (1974).
A. Leo, C. Hansch, and D. Elkins. Partition coefficients and their uses. Chem. Rev. 71:525–616 (1971).
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Jenke, D.R. Effect of Solution Phase Composition on the Interaction Between Aqueous Model Solutes and Polymeric Container Materials. Pharm Res 8, 782–786 (1991). https://doi.org/10.1023/A:1015866420836
Issue Date: