Abstract
In this study the osteoconductive properties of strontium based ionomeric cements (ICs) named, LG125 and LG119, as well as zinc-based ICs, designated by LG130 and LG132, were compared. Wet ICs were surgically implanted into the femora of weaned Wistar rats for 4 weeks. To assess the percentage osseointegration the perimeter of the implant and the perimeter of bone in contact with the implant were measured using a pointer (the length of bone/implant interfacial contact). Osteoconduction was determined by taking six points at random around the perimeter of each ionomeric rod measuring the thickness of newly formed bone. The degree of osteoconduction was taken as the average thickness of new bone produced on the implant surface. It was found that osteoconduction was greatest in the strontium based IC implant LG125. From these studies it can be concluded that the composition LG125 might provide a useful purpose as a bone cement.
Similar content being viewed by others
References
L. M. Jonck, C. J. Grobelaar and H. Strating, J. Clin. Mater. 4 (1989) 85.
G. Geyer and J. Helms, Eur. Arch. Otorhinolaryngol. 250(5) (1993) 253.
R. T. Ramsden, R. C. D. Herdman and R. H. Lye, J. Laryng. Otol. 106 (1992) 949.
L. M. Jonck and C. G. Grobelaar, Clin. Mats. 6 (1990) 323.
K. K. Johal, A. J. Devlin, G. T. Craig, R. G. Hill and I. M. Brook, J. Mater. Sci. Mater. Med. 6 (1995) 690.
R. G. Hill, E. Debarra, S. Griffin, G. Henn, A. J. Devlin, P. V. Hatton, I. M. Brook, K. Johal and G. T. Craig, Key Eng. Mater. 99–100 (1995) 315.
K. K. Johal, G. T. Craig, A. J. Devlin, P. V. Hatton, E. Debarra, R. G. Hill and I. M. Brook, J. Dent. Res. 74 (1995) 826.
A. J. Devlin, K. K. Johal, P. V. Hatton, G. T. Craig, E. Debarra, R. G. Hill and I. M. Brook, ibid. 74 (1995) 826.
J. W. Nicholson, J. H. Braybrook and E. A. Wasson, Rev. Biomater. Sci. Polymer. 2(4) (1991) 277.
M. D. Grynpas and P. J. Marie, Bone 11(5) (1990) 313.
P. J. Marie, M. T. Gabra, M. Hott and L. Miravet, Miner. Electrolyte Metab. 11 (1985) 5.
A. E. Sobel, Y. Cohen and B. Kramer, Biochem. J. 29 (1935) 2640.
M. Yamaguchi and Y. H. Goa, Gen. Pharmac. 30(3) (1988) 423.
J. Eberle, S. Schmidmayer, R. G. Erben, M. Stangassinger and H. P. Roth, J. Trace Elem. Med. Biol. 13(1–2) (1999) 21.
A. C. Guyton, in “Textbook of Medical Physiology” (WB Saunders Company, 1995) p. 943.
T. Albrektsson and C. Johanssen, in “The Bone Biomaterial Interface”, edited by J. E. Davies (University of Toronto Press, 1994) p. 257.
A. Pizzoferrato et al. in “Advances in Biomaterials”, edited P. J. Doherty (Elsevier Science, Amsterdam, 1992) p. 63.
T. Morohashi, T. Sano, K. Hanai and S. Yamada, Jpn. J. Pharmcol. 68 (1995) 153.
E. F. Ferraro, R. Carr and K. Zimmerman, Calcif. Tissue Int. 35 (1983) 258.
R. A. Corradino and R. H. Wasserman, Proc. Soc. Exp. Biol. Med. 133 (1970) 960.
G. Boivin and P. J. Meunier, “The Metabolic and Molecular Basis of Acquired Disease” (Bailliere and Tindall, London 1990) p. 1803.
B. L. Riggs, S. F. Hodgson, W. M. O'Fallon, E. Y. S. Chao, H. W. Whaner, J. M. Muhs, S. L. Cedel and L. J. Melton, New Eng. J. Med. 322 (1990) 802.
D. T. Baylink and O. S. Bernstein, Clin. Orthop. 55 (1967) 51.
M. Yamaguchi, H. Oishi and Y. Suketa, Biochem. Pharmacol. 36 (1987) 22, 4007.
B. S. Moonga and D. W. Dempster, J. Bone Miner. Res. 10(3) (1995) 453.
A. Marusic, K. Kos, A. Stavljenic and S. Vukicevic, Biol. Trace Elem. Res. 29(2) (1991) 165.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Johal, K.K., Mendoza-Suárez, G., Escalante-García, J.I. et al. In vivo response of strontium and zinc-based ionomeric cement implants in bone. Journal of Materials Science: Materials in Medicine 13, 375–379 (2002). https://doi.org/10.1023/A:1014336517741
Issue Date:
DOI: https://doi.org/10.1023/A:1014336517741