Skip to main content
Log in

A semi-empirical formula for HPGe detector efficiency calibration

  • Published:
Journal of Radioanalytical and Nuclear Chemistry Aims and scope Submit manuscript

Abstract

The precision obtainable by instrumental neutron activation analysisdepends strongly on the quality of the calibration of the gamma-ray spectrometerused for measuring the irradiated samples. Even when relative standardizationis employed, practical experience has shown the importance of detector calibration.This is especially relevant when radionuclides of varying activities are involved.The problems often encountered are those of intolerable high dead time andthe occurrence of summed peaks in the gamma-ray spectra. A simple but accuratesemi-empirical formula is presented that could effectively predict the efficiencyof a detector at any source-to-detector distance. Experimental data obtainedat 0, 50, 100, 200 mm source-to-detector distances are used to demonstratethe usefulness of this formulation. In addition, nine elements were analyzedin the NIST Orchard Leaves using absolute standardization including four elementsSm, Ta, Au, and La for which no certified values could be obtained.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. A. Simonits, F. De Corte, J. HOSTE, J. Radioanal. Nucl. Chem., 31 (1976) 467.

    Google Scholar 

  2. R. Tramontano, U. R. Vanin, Appl. Radiation Isotopes, 51,3 (1999) 323.

    Google Scholar 

  3. V. D. Martinez, R. T. Minardi, R. A. Barrea, D. M. Hidalgo, P. A. Derosa, M. M. Arboli, X-ray Spectrometry, 27 (1998) 321.

    Google Scholar 

  4. C. Bergerioux, G. Kennedy, L. Zikovsky, J. Radioanal. Chem., 50 (1979) 229.

    Google Scholar 

  5. I. Salma, E. ZEmplen-Papp, Nucl Instr. Meth. Phys. Res., A435 (1999) 462.

    Google Scholar 

  6. R. Helmer, P. Van Assche, C. Van Derleun, Atomic Data and Nuclear Data Tables, 24 (1979) 39.

    Google Scholar 

  7. L. V. East, Nucl. Instr. Meth., 127 (1974) 73.

    Google Scholar 

  8. L. A. McNelles, J. L. Campbell, Nucl. Instr. Meth., 127 (1974) 73.

    Google Scholar 

  9. K. Kawade, M. Ezuka, H. Yamamoto, K. Sugioka, T. Katch, Nucl. Instr. Meth., 190 (1981) 101.

    Google Scholar 

  10. L. Wielopolski, Nucl. Instr. Meth., 143 (1977) 577.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Oladipo, A. A semi-empirical formula for HPGe detector efficiency calibration. Journal of Radioanalytical and Nuclear Chemistry 249, 607–611 (2001). https://doi.org/10.1023/A:1013254400618

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1023/A:1013254400618

Keywords

Navigation