Skip to main content
Log in

Differences in PIXE signal-to-noise ratios and detection limits for conducting targets insulated with glass

  • Published:
Journal of Radioanalytical and Nuclear Chemistry Aims and scope Submit manuscript

Abstract

Extended work, involving background effects, to confirm the charge-inducedX-ray (CHIX) phenomenon is reported. PIXE studies in pure metal targets surroundedby a special type of glass insulating material (Macor) produced higher backgrounds,in general, compared to corresponding observations made in the absence ofthe insulator. Experiments were conducted using low-energy protons of 700keV and beam currents ranging between 1–10 nA. Signal-to-noise ratiosand detection limits are compared and discussed in the light of the unusualhigh X-ray yields produced by the CHIX phenomenon.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. M. Peisach,A. E. Pillay,C. A. Pineda, Nucl. Instr. Meth., B75 (1993) 14.

    Google Scholar 

  2. R. C. M. Mboweni,C. A. Pineda,M. Peisach,A. E. Pillay, Nucl. Instr. Meth., B85 (1994) 138.

    Google Scholar 

  3. M. Peisach,C. A. Pineda,A. E. Pillay, Nucl. Instr. Meth., B85 (1994) 100.

    Google Scholar 

  4. M. Peisach,C. A. Pineda,A. E. Pillay, J. Radional. Nucl. Chem., 178 (1994) 387.

    Google Scholar 

  5. M. Peisach,C. A. Pineda,A. E. Pillay,K. A. Springhorn, Nucl. Instr. Meth., B94 (1994) 540.

    Google Scholar 

  6. A. E. Pillay,M. Peisach, Nucl. Instr. Meth., B94 (1994) 545.

    Google Scholar 

  7. A. E. Pillay,M. Peisach, J. Radioanal. Nucl. Chem., 188 (1994) 453.

    Google Scholar 

  8. A. E. Pillay,M. Peisach , J. Radioanal. Nucl. Chem., 189 (1995) 283.

    Google Scholar 

  9. A. E. Pillay,M. Peisach, J. Radioanal. Nucl. Chem., 199 (1995) 65.

    Google Scholar 

  10. A. E. Pillay,M. Peisach, J. Radioanal. Nucl. Chem., 199 (1995) 125.

    Google Scholar 

  11. A. E. Pillay,M. Peisach, J. Radioanal. Nucl. Chem., 200 (1995) 53.

    Google Scholar 

  12. A. E. Pillay,M. Peisach, J. Radioanal. Nucl. Chem., 200 (1995) 85.

    Google Scholar 

  13. A. E. Pillay,M. Peisach, X-Ray Spectrom., 24 (1995) 118.

    Google Scholar 

  14. A. E. Pillay,M. Peisach, J. Chem. Educ., 73 (1996) 508.

    Google Scholar 

  15. I. S. GILES, PhD Thesis, University of Cape Town, 1978.

  16. Indiana University Cyclotron Facility, Scientific and Technical Report, 1987, p. 165.

  17. S. A. E. Johansson,T. B. Johansson, Nucl. Instr. Meth., 137 (1976) 473.

    Google Scholar 

  18. A. E. Pillay,J. J. Kritzinger,K. Springhorn, J. Radioanal. Nucl. Chem., 237 (1998) 35.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Pillay, A. Differences in PIXE signal-to-noise ratios and detection limits for conducting targets insulated with glass. Journal of Radioanalytical and Nuclear Chemistry 250, 181–183 (2001). https://doi.org/10.1023/A:1013215904930

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1023/A:1013215904930

Keywords

Navigation