Skip to main content
Log in

Oxidized implants and their influence on the bone response

  • Published:
Journal of Materials Science: Materials in Medicine Aims and scope Submit manuscript

Abstract

Surface oxide properties are regarded to be of great importance in establishing successful osseointegration of titanium implants. Despite a large number of theoretical questions on the precise role of oxide properties of titanium implants, current knowledge obtained from in vivo studies is lacking. The present study is designed to address two aspects. The first is to verify whether oxide properties of titanium implants indeed influence the in vivo bone tissue responses. The second, is to investigate what oxide properties underline such bone tissue responses. For these purposes, screw-shaped/turned implants have been prepared by electrochemical oxidation methods, resulting in a wide range of oxide properties in terms of: (i) oxide thickness ranging from 200 to 1000 nm, (ii) the surface morphology of barrier and porous oxide film structures, (iii) micro pore configuration – pore sizes<8 μm by length, about 1.27 μ2 to 2.1 μm2 by area and porosity of about 12.7–24.4%, (iv) the crystal structures of amorphous, anatase and mixtures of anatase and rutile type, (v) the chemical compositions of TiO2 and finally, (vi) surface roughness of 0.96–1.03 μm (Sa). These implant oxide properties were divided into test implant samples of Group II, III, IV and V. Control samples (Group I) were turned commercially pure titanium implants. Quantitative bone tissue responses were evaluated biomechanically by resonance frequency analysis (RFA) and removal torque (RT) test. Quantitative histomorphometric analyses and qualitative enzyme histochemical detection of alkaline (ALP) and acidic phosphatase (ACP) activities were investigated on cut and ground sections after six weeks of implant insertion in rabbit tibia. In essence, from the biomechanical and quantitative histomorphometric measurements we concluded that oxide properties of titanium implants, i.e. the oxide thickness, the microporous structure, and the crystallinity significantly influence the bone tissue response. At this stage, however, it is not clear whether oxide properties influence the bone tissue response separately or synergistically.

© 2001 Kluwer Academic Publishers

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. B. Kasemo and J. Lausmaa, in “The Bone-Biomaterials Interface, Toronto”, edited by J. E. David (University of Toronto Press, 1991).

  2. T. Albrektsson, P. I. BrÅnemark, H. A. Hansson, B. Kasemo, K. Larsson, I. LundstrÖm, D. Mcqueen and R. Skalak, Ann. Biomed. Eng. 11 (1983) 1.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Y. T. Sul.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Sul, Y.T., Johansson, C.B., Jeong, Y. et al. Oxidized implants and their influence on the bone response. Journal of Materials Science: Materials in Medicine 12, 1025–1031 (2001). https://doi.org/10.1023/A:1012837905910

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1023/A:1012837905910

Keywords

Navigation