Abstract
We describe the development of detector arrays and electronics for large-volume, hand-held CdZnTe detectors with the same counting efficiency as portable NaI(Tl) detectors presently used for nuclear material measurement applications. The pulse-height resolution of the multi-element detectors is at least three times better than NaI(Tl) over a wide energy range (from 100 keV to several MeV), enabling more accurate measurements of gamma-rays emitted by special nuclear material. Arrays of up to eight coplanar grid detectors can be combined to make detectors ranging in size from 4 to 14 cm3. Because the number of spectroscopy channels is small, low-power, hand-held detectors can be manufactured with conventional printed circuit board technology, thus keeping the cost of multi-element detectors to a minimum. The design and performance of an 8-element detector is presented.
Similar content being viewed by others
References
D. J. Olega, J. P. Faurie, S. Sivananthan, P. M. Raccah, Appl. Phys. Lett., 47 (1985) 1172.
D. S. McGregor, H. Hermon, Nucl. Instr. Meth. Phys. Res. A, 395 (1997) 101.
P. N. Luke, E. E. Eissler, IEEE Trans. Nucl. Sci., 43 (1996) 1481.
M. Amman, J. S. Lee, P. N. Luke, Electron transport uniformity characterization of CdZnTe using alpha particles, Proc. of SPIE, Vol. 3446, 1998, p. 179.
T. H. Prettyman, C. E. Moss, J. D. Valentine et al., Trans. Am. Nucl. Soc., 79 (1998) 108.
C. E. Moss, K. D. Ianakiev, T. H. Prettyman et al., Performance of multi-element CdZnTe detectors, Proc. of SPIE, Vol. 3768, 1999, p. 320.
P. N. Luke, Appl. Phys. Letters, 65 (1994) 2884.
T. H. Prettyman, M. K. Smith, S. A. Soldner, Design and characterization of cylindrical CdZnTe detectors with coplanar grids, Proc. of SPIE, Vol. 3768, 1999, p. 339.
F. L. Augustine, Nucl. Instr. Meth. Phys. Res., A 353 (1994) 201.
K. J. Matherson, H. B. Barber, H. H. Barrett et al., IEEE Trans. Nucl. Sci., 45 (1998) No. 3, 354.
C. G. Jakobson, G. Asa, S. Barlev et al., Nucl. Instr. Meth. Phys. Res., A 428 (1999) 113.
R. Arlt, V. Gryshchuk, P. Sumah, Nucl. Instr. Meth. Phys. Res., A 428 (1999) 127.
F. S. Goulding, D. A. Landis, IEEE Trans. Nucl. Sci., 29 (1982) No. 3.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Prettyman, T.H., Ianakiev, K.D., Moss, C.E. et al. Development of high efficiency, multi-element CdZnTe detectors for portable measurement applications. Journal of Radioanalytical and Nuclear Chemistry 248, 295–300 (2001). https://doi.org/10.1023/A:1010699102355
Issue Date:
DOI: https://doi.org/10.1023/A:1010699102355