Skip to main content
Log in

Development of high efficiency, multi-element CdZnTe detectors for portable measurement applications

  • Published:
Journal of Radioanalytical and Nuclear Chemistry Aims and scope Submit manuscript

Abstract

We describe the development of detector arrays and electronics for large-volume, hand-held CdZnTe detectors with the same counting efficiency as portable NaI(Tl) detectors presently used for nuclear material measurement applications. The pulse-height resolution of the multi-element detectors is at least three times better than NaI(Tl) over a wide energy range (from 100 keV to several MeV), enabling more accurate measurements of gamma-rays emitted by special nuclear material. Arrays of up to eight coplanar grid detectors can be combined to make detectors ranging in size from 4 to 14 cm3. Because the number of spectroscopy channels is small, low-power, hand-held detectors can be manufactured with conventional printed circuit board technology, thus keeping the cost of multi-element detectors to a minimum. The design and performance of an 8-element detector is presented.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. D. J. Olega, J. P. Faurie, S. Sivananthan, P. M. Raccah, Appl. Phys. Lett., 47 (1985) 1172.

    Google Scholar 

  2. D. S. McGregor, H. Hermon, Nucl. Instr. Meth. Phys. Res. A, 395 (1997) 101.

    Google Scholar 

  3. P. N. Luke, E. E. Eissler, IEEE Trans. Nucl. Sci., 43 (1996) 1481.

    Google Scholar 

  4. M. Amman, J. S. Lee, P. N. Luke, Electron transport uniformity characterization of CdZnTe using alpha particles, Proc. of SPIE, Vol. 3446, 1998, p. 179.

    Google Scholar 

  5. T. H. Prettyman, C. E. Moss, J. D. Valentine et al., Trans. Am. Nucl. Soc., 79 (1998) 108.

    Google Scholar 

  6. C. E. Moss, K. D. Ianakiev, T. H. Prettyman et al., Performance of multi-element CdZnTe detectors, Proc. of SPIE, Vol. 3768, 1999, p. 320.

    Google Scholar 

  7. P. N. Luke, Appl. Phys. Letters, 65 (1994) 2884.

    Google Scholar 

  8. T. H. Prettyman, M. K. Smith, S. A. Soldner, Design and characterization of cylindrical CdZnTe detectors with coplanar grids, Proc. of SPIE, Vol. 3768, 1999, p. 339.

    Google Scholar 

  9. F. L. Augustine, Nucl. Instr. Meth. Phys. Res., A 353 (1994) 201.

    Google Scholar 

  10. K. J. Matherson, H. B. Barber, H. H. Barrett et al., IEEE Trans. Nucl. Sci., 45 (1998) No. 3, 354.

    Google Scholar 

  11. C. G. Jakobson, G. Asa, S. Barlev et al., Nucl. Instr. Meth. Phys. Res., A 428 (1999) 113.

    Google Scholar 

  12. R. Arlt, V. Gryshchuk, P. Sumah, Nucl. Instr. Meth. Phys. Res., A 428 (1999) 127.

    Google Scholar 

  13. F. S. Goulding, D. A. Landis, IEEE Trans. Nucl. Sci., 29 (1982) No. 3.

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Prettyman, T.H., Ianakiev, K.D., Moss, C.E. et al. Development of high efficiency, multi-element CdZnTe detectors for portable measurement applications. Journal of Radioanalytical and Nuclear Chemistry 248, 295–300 (2001). https://doi.org/10.1023/A:1010699102355

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1023/A:1010699102355

Keywords

Navigation