Skip to main content
Log in

Variations in plasmid content during Escherichia coli cultivations detected by on-line flow injection processing

  • Published:
Biotechnology Letters Aims and scope Submit manuscript

Abstract

An integrated flow injection process for analysis of intracellular components of microbes has been used to monitor plasmid content in Escherichia coli cultivations inoculated with cells subcultured in the presence or absence of ampicillin. The system allows sampling, sample handling, cell disruption, separation of intracellular components, and analysis in a semi-on-line mode of operation. The time scale for the assay is in the range 15 min (plasmid peak) to 25 min (complete assay cycle). As expected, lower initial plasmid content was found using an inoculum subcultured in the absence of ampicillin. More importantly, significant decrease in plasmid content was detected in the later stages of the cultivations (grown in ampicillin containing medium) even when using inoculum subcultured in the presence of ampicillin. This illustrates the versatility of the system, which allows monitoring of plasmid content as the cultivation proceeds.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Birnboim HC, Doly J (1979) A rapid alkaline extraction procedure for the screening of recombinant plasmid DNA. Nucl. Acid Res. 7: 1513–1523.

    Google Scholar 

  • Breuer S, Marzban G, Cserjan-Puschman M, Derrschmid E, Bayer K (1998) Off-line quantitative monitoring of plasmid copy number in bacterial fermentation by capillary electrophoresis. Electrophoresis 19: 2474–2478.

    Google Scholar 

  • Csöregi E, Laurell T, Katakis I, Heller A, Gorton L (1995) On-line glucose monitoring by using microdialysis sampling and amperometric detection based on wired glucose oxidase in carbon paste. Mikrochim. Acta 121: 31–40.

    Google Scholar 

  • Ferreira GNM, Cabral JMS, Prazeres DMF (2000) Anion exchange purification of plasmid DNA using expanded bed adsorption. Bioseparation 9: 1–6.

    Google Scholar 

  • Huang T, Perctti SW, Bryers JD (1993) Plasmid retention and gene expression in suspended and biofilm cultures of recombinant E. coli D H5 a (pMJR 1750). Biotechnol. Bioeng. 41: 211–220.

    Google Scholar 

  • Kyröläinen M, Håkanson H, Mattiasson B (1995) On-line calibration of a computerised biosensor system for continuous measurements of glucose and lactate. Biotechnol. Bioeng. 45: 122–128.

    Google Scholar 

  • Lammers F, Scheper T (1999) Thermal biosensors in biotechnology. In: Scheper T, ed. Advances in Biochemical Engineering Biotechnology, Vol. 64. Berlin: Springer-Verlag, pp. 35–67.

    Google Scholar 

  • Lee D-C, Kim G-J, Cha Y-K, Lee C-Y, Kim H-S (1997) Mass production of thermostable D-hydantoinase by batch culture of recombinant Escherichia coli with a constitutive expression system. Biotechnol. Bioeng. 56: 449–455

    Google Scholar 

  • Lee SY, Yim KS, Chang HN, Chand YK (1994) Construction of plasmid, estimation of plasmid stability, and use of stable plasmid for the production of poly(3-hydroxy butyric acid) by recombinant Escherichia coli. J. Biotechnol. 32: 203–211.

    Google Scholar 

  • Mattiasson B, Nandakumar MP (1999) Binding assays in heterogeneous media using a flow injection system with an expanded micro-bed adsorption column. Bioseparation 8: 237–245.

    Google Scholar 

  • Nandakumar MP, Nandakumar R, Mattiasson B (2000) Fluorimetric quantification of intracellular lactate dehydrogenase during fermentation using flow injection analysis. Biotechnol. Lett. 22: 1453–1457.

    Google Scholar 

  • Nandakumar MP, Nordberg Karlsson E, Mattiasson B (2001) Integrated flow injection processing for on-line quantification of plasmid DNA. Biotechnol. Bioeng. (in press).

  • Nandakumar MP, Sapre A, Lali A, Mattiasson B (1999) Monitoring of low glucose concentrations in fermentation broth. Appl. Microbiol. Biotechnol. 52: 502–507.

    Google Scholar 

  • Nilsson M, Håkansson H, Mattiasson B. (1992) Evaluation of a sequential competitive binding assay. Proc. Control Quality 597: 383–389.

    Google Scholar 

  • Sambrook J, Fritsch EF, Maniatis T (1989) Molecular Cloning. A Laboratory Manual, 2nd edn. Cold Spring Harbor, NY: Cold Spring Harbor Laboratory Press.

    Google Scholar 

  • Seo JH, Bailey JE (1986) Continuous cultivation of recombinant E. coli: existence of optimum dilution rate for maximum plasmid and gene product concentrations. Biotechnol. Bioeng. 28: 1590–1594.

    Google Scholar 

  • Smith MA, Bidochka MJ (1998) Bacterial fitness and plasmid loss: the importance of culture conditions and plasmid size. Can. J. Microbiol. 44: 351–355.

    Google Scholar 

  • Tocaj A, Nandakumar MP, Holst O, Mattiasson B (1999) Flow injection analysis of intracellular β-galactosidase in Escherichia coli cultivations, using an on-line system including cell disruption, debris separation and immunochemical quantification. Bioseparation 8: 255–267.

    Google Scholar 

  • Xie B, Danielsson B (1996) An integrated thermal biosensor for array for multianalyte determination demonstrated with glucose, urea and penicillin. Anal. Lett. 29: 1921–1932.

    Google Scholar 

  • Zang J, Zhou H, Ji Z, Regnier F (1998) Monoclonal antibody production with on-line harvesting and process monitoring. J. Chromatogr. B707: 257–265.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to B. Mattiasson.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Nandakumar, M., Nordberg Karlsson, E. & Mattiasson, B. Variations in plasmid content during Escherichia coli cultivations detected by on-line flow injection processing. Biotechnology Letters 23, 1135–1140 (2001). https://doi.org/10.1023/A:1010568019191

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1023/A:1010568019191

Navigation