Performance of a Plastic Optical Fiber Stylet for Tracheal Intubation of a Dog

  • Published:
Journal of Clinical Monitoring and Computing Aims and scope Submit manuscript

Abstract

Objective. We set out to establish whether a novel plastic optical fiber incorporated into an endotracheal tube (ETT) stylet could be used for intubation of a dog. A secondary objective examined the need for a direct illumination source from a laryngoscope. Lastly, the fragility of the system was tested. Methods. An anesthetized dog was repeatedly intubated using a laryngoscope to elevate the tongue and the view of the larynx conducted through the plastic optical fiber stylet (placed within an endotracheal tube) and displayed on a television monitor. Four prototype identical stylets were tested. Repeated intubations were attempted with each stylet and graded as either successful or failed. All four stylets were tested 10 times each using a Miller 4 blade and direct illumination from the laryngoscope. Two of the four stylets were reused during an additional 10 intubation attempts using a Miller 4 blade and laryngoscope (without batteries) with only ambient light. Finally, one stylet was used for intubation after 10, 20, 30, 40 and 50 sharp 90 degree bend-and-straighten cycles using a Miller 4 blade and laryngoscope for direct illumination. Results. All attempted intubations were successful. However, the image quality was dramatically better when direct illumination from a laryngoscope was used than when ambient light was used. One plastic optical fiber stylet was successfully used to intubate after having been used for 20 intubations and 50 sharp 90 degree bend-and-straighten cycles. A partial lens separation occurred between the 41st and 50th bend cycle but the image remained adequate enough to successfully intubate again. Conclusions. A novel plastic optical fiber incorporated into an ETT stylet can be used with a laryngoscope for intubation of a dog. Direct illumination from a laryngoscope provides a better television monitor image than when only ambient light is used. The system was durable, withstanding over 20 uses and 40 sharp bend-and-straighten cycles before a lens separation failure occurred.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

REFERENCES

  1. Murphy P. A fibre-optic endoscope used for nasal intubation. Anesthesia 1967; 22(3): 489–491

    Google Scholar 

  2. Taylor PA, Towey RM. The broncho-fiberscope as an aid to endotracheal intubation. Br J Anaesth 1972; 44: 611–612

    Google Scholar 

  3. Stiles CM, Stiles QR, Denson JS. A flexible fiber optic laryngoscope. JAMA 1972; 221: 1246–1247

    Google Scholar 

  4. Katz RL, Berci G. The optical stylet–A new technique for adults and children with specific reference to teaching. Anesthesiology 1979; 51(3): 251–254

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Gravenstein, D., Lampotang, S., Melker, R. et al. Performance of a Plastic Optical Fiber Stylet for Tracheal Intubation of a Dog. J Clin Monit Comput 14, 271–274 (1998). https://doi.org/10.1023/A:1009961728812

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1023/A:1009961728812

Navigation