Schmitt C, Montero M, Melichericik J. Significance of supraventricular tachyarrhythmias in patients with implanted pacing cardioverter defibrillator. PACE. 1994; 17:295-302.
O’Nunain SS, Roelke M, Trouton TG, Osswald S, Kim YH, Sosa-Suarez G, Brooks DR, McGovern B, Guy M, Torchiana DF, Vlahakes GJ, Garan H, Ruskin JN. Limitations and late complications of third-generation automatic cardioverter defibrillators. Circulation. 1995;91:2204-2213.
Grimm W, Flores BF, Marchlinski FE. Electrocardiographically documented unnecessary spontaneous shocks in 241 patients with implantable cardioverter defibrillator. PACE. 1992;15:1667-1673.
Fahy GJ, Sgarbossa EB, Tchou PJ, Pinski SL. Hospital readmission in patients treated with tiered-therapy implantable defibrillators. Circulation. 1996;94:1350-1356.
Swerdlow CD, Ahern T, Chen PS, Hwang C, Gang E, Mandel W, Kass RM, Peter CT. Underdetection of ventricular tachycardia by algorithms to enhance specificity in a tiered-therapy cardioverter-defibrillator. J Am Coll Cardiol. 1994;24:416-424.
Schaumann A, von zur Mühlen F, Gonska BD, Kreuzer H. Enhanced detection criteria in implantable cardioverter-defibrillators to avoid inappropriate therapy. Am J Cardiol 1996;78(suppl 5A):42-50.
Nair M, Saoudi N, Kroiss D, Letac B. Automatic arrhythmia identification using analysis of the atrioventricular association: application to a new generation of implantable defibrillators. Circulation. 1997;95:967-973.
Lavergne T, Daubert JC, Chauvin M, Dolla E, Kacet S, Leenhardt A, Mabo P, Ritter P, Sadoul M, Saoudi N, Henry C, Nitzshe R, Ripart A, Murgatroyd F. Preliminary clinical experience with the first dual chamber pacemanker defibrillator. PACE. 1997;20[Pt.II]:182-188.
Lampert R, Rosenfeld I, McPherson C, Lewis R, Vanzetta A, Batsford W. Initial single-center experience with an advanced third-generation investigational defibrillator. PACE. 1967;19:2072-2082.
Brugada J, Mont L, Figueiredo M, Valentino M, Matas M, Novarro-Lópes F. Enhanced detection criteria in implantable defibrillators. J Cardiovasc Electrophysiol. 1998;9: 261-268.
Newby KH, Zimerman L, Wharton JM, Kent V, Kearney M, Brandon MJ, Natale A. Radiofrequency ablation of atrial flutter and atrial tachycardias in patients with permanent indwelling catheters. PACE. 1996;19:1612-1617.
Schumacher B, Tebbenjohanns J, Jung W, Korte T, Pfeiffer D, Lüderitz. Radiofrequency catheter ablation of atrial flutter that elicits inappropriate implantable cardioverter defibrillator discharge. PACE. 1997;20:125-127.
Heisel A, Jung J, Fries R, Schieffer H, Özbeck C. Atrial defibrillation: can modifications in current implantable cardioverter-defibrillators achieve this? Am J Cardiol 1996; 78(suppl 5A):119-127.