Abstract
Recent advances in technology have brought many kinds of monitoring devicesinto the operating room (OR). The information gathered by monitors can bechanneled to the operating ward information system via a local area network(LAN). Connecting patients to monitors and monitors to the LAN, however,requires a large number of cables. This wiring is generally inconvenient andparticularly troublesome if the layout of the OR is rearranged. From thispoint of view, wireless transmission seems ideally suited to clinicalsettings. Currently, two modes of wireless connectivity are available:radio-frequency (RF) waves or infrared (IR) waves. Some reports suggest thatRF transmission is likely to cause electromagnetic interference (EMI) inmedical devices such as cardiac pacemakers or infusion pumps. The risk ofmalfunctioning life-sustaining devices and the catastrophic consequences thiswould have on seriously ill patients rules out the use of RF. Here, we reportan IR system using IR modems for LAN connectivity in the OR. In this study,we focused on the possible detrimental effects of EMI during wirelessconnectivity. In our trial, we found no evidence of EMI of IR modems with anyof the medical devices we tested. Furthermore, IR modems showed similarperformance to a wired system even in an electrically noisy environment. Weconclude that IR wireless connectivity can be safely and effectively used inORs.
Similar content being viewed by others
REFERENCES
Barbaro V, Bartolini P, Donato A, Militello C, Altamura G, Ammirati F, Santini M. Do European GSM mobile cellular phones pose a potential risk to pacemaker patients? Pacing Clin Electrophysiol 1995; 18 (6): 1218-1224
Clifford KJ, Joyner KH, Stroud DB, Wood M, Ward B, Fernandez CH. Mobile telephones interfere with medical electrical equipment. Aus Phys Eng Sci Med 1994; 17 (1): 23-27
Yesil M, Bayata S, Postaci N, Aydin C. Pacemaker inhibition and asystole in a pacemaker dependent patient. Pacing Clin Electrophysiol 1995; 18 (10): 1963
Trudeau S, Ladue M. Radiofrequency interference with medical devices. A technical information statement. IEEE Eng Med Biol Mag 1998; 17 (3): 111-114
Baba I, Ito T, Furuhata H, Nojima T, Kano T, Tsubota S, Watanabe S. Experimental study of electromagnetic interference from cellular phones with electronic medical equipment. J Clin Eng 1998; 23 (2): 122-134
Hayes DL, Wang PJ, Reynolds DW, M Estes I, Griffth JL, Steffens RA, Carlo GL, Findlay GK, Johnson CM. Interference with cardiac pacemakers by cellular telephones. N Engl J Med 1997; 336 (21): 1473-1479
Hirayama M, Tanaka N. Infrared rays application to optical LAN systems. DOC: IEEE 1997; 802.11: 1-21
Gfeller FR, Bapst U. Wireless in-house data communication via diffuse infrared radiation. Proc IEEE 1979; 67: 1474
Šantić A. Theory and application of diffuse infrared biotelemetry. Crit Rev Biomed Eng 1991; 18 (4): 289-309
Hof AL, Bonga GJ, Swarte FG, de Pater L. Modular PPM telemetry system with radio, infrared and inductive loop transmission. Med Biol Eng Comput 1994; 32 (1): 107-112
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Hagihira, S., Takashina, M., Mori, T. et al. Infrared Transmission of Electronic Information via LAN in the Operating Room. J Clin Monit Comput 16, 171–175 (2000). https://doi.org/10.1023/A:1009911208828
Issue Date:
DOI: https://doi.org/10.1023/A:1009911208828