References
Marchlinski FE, Callans DJ, Gottlieb CD, Schwartzman D, Preminger M. Benefits and lessons learned from stored electrogram information in implantable defibrillators. J Cardiovasc Electrophysiol 1995;6:832-851
Auricchio A, Hartung W, Geller C, Klein H. Clinical relevance of stored electrograms for implantable cardioverter defibrillator troubleshooting and understanding of mechanisms for ventricular tachyarrhythmias. Am J Cardiol 1996;78(suppl 5A):33-41
Hook BG, Callans DJ, Hsia HH. Stored ventricular electrogram analysis in the management of patients with implantable cardioverter defibrillators. In Estes NAM, Manolis AS, Wang PJ, eds. Implantable Cardioverter Defibrillators: A Comprehensive Textbook. Boston: Marcel Dekker Publishers, 1994:99-101.
Callans DJ, Hook BG, Marchlinski FE. Use of bipolar recordings from patch-patch and rate sensing leads to distinguish ventricular tachycardia from supraventricular rhythms in patients with implantable cardioverter defibrillators. PACE 1991;14:1917-1922
Hook BG, Callans DJ, Kleiman RB, Flores BT, Marchlinski FE. Implantable cardioverter defibrillator therapy in the absence of significant symptoms. Rhythm diagnosis and management aided by stored electrogram analysis. Circulation 1993;87: 1897-1906
Sarter BH, Hook BG, Callans DJ, Marchlinski FE. Effect of bundle branch block on local electrogram morphologic features: Implications for arrhytmia diagnosis by stored electrogram analysis. Am Heart J 1996;131:947-952
Callans DJ, Hook BG, Kleiman RB, Mitra RL, Flores BT, Marchlinski FE. Unique sensing errors in third-generation implantable cardioverter defibrillators. J Am Coll Cardiol 1993;22:1135-1140
Berul CI, Callans DJ, Schwartzman DS, Preminger MW, Gottlieb CD, Marchlinski FE. Comparison of initial detection and redetection of ventricular fibrillation in a transvenous defibrillator system with automatic gain control. J Am Coll Cardiol 1995;25:431-436
Marchlinski FE, Schwartzman D, Gottlieb CD, Gonzalez-Zuelgaray J, Callans DJ. Electrical events associated with ventricular tachycardia initiation and their prevention. In Zipes DP, Jalife J, eds. Cardiac Electrophysiology, 2nd ed. Philadelphia: WB Saunders Co., 1995: 863-877
Roelke M, Garan H, McGovern BA, Ruskin JN. Analysis of the initiation of spontaneous monomorphic ventricular tachycardia by stored intracardiac electrograms. J Am Coll Cardiol 1994;23:117-122
Grubman EM, Pavri BB, Shipman T, Britton N, Kocovic DZ. Cardiac death and stored electrograms in patients with third-generation implantable cardioverter defibrillators. J Am Coll Cardiol 1998;32:1056-1062
Sarter BH, Callans DJ, Gottlieb CD, Schwartzman DS, Marchlinski FE. Implantable defibrillator diagnostic storage capabilities: evolution, current status, and future utilization. PACE 1998;21:1287-1298
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Nayak, H.M., Marchlinski, F.E. Interpretation and Application of Stored Electrograms. Card Electrophysiol Rev 2, 313–318 (1998). https://doi.org/10.1023/A:1009911029980
Issue Date: