Abstract
In the implantable cardioverter defibrillator era the necessity for lead removal is not negligible. A specially designed extraction lead system for percutaneous removal of such leads is lacking, in contrast to the existing pacing lead extraction systems. We report the successful percutaneous extraction of four implantable cardioverter defibrillator leads in three patients because of lead malfunction using a novel pacemaker lead extraction system, the VascoExtor (VascoMed) system. Three leads were successfully removed in two patients using traction with special locking stylets from the superior approach. One lead was removed using the system's additional extraction tools through the femoral approach. There were no complications. This preliminary experience shows that the VascoExtor (VascoMed) pacemaker lead extraction system can also be used in implantable cardioverter defibrillator lead extraction safely and effectively. In addition to the locking stylets, adjunct percutaneous extraction tools may be needed in some cases.
Similar content being viewed by others
References
Wunderly D, Maloney J, Edel T, et al. Infection in implantable cardioverter defibrillator patients. PACE 1990;13:1360–1364.
Espinosa RL, Hayes DL, Vlietstra RE, et al. The Dotter retriever and pigtail catheter: Efficacy in extraction of chronic transvenous pacemaker leads. PACE 1993;16:2337–2342.
Smith HJ, Fearnot NE, Byrd CL, et al. Five years experience with intravascular lead extraction. PACE 1994;17(Pt. II):2016–2020.
Manolis AS, Maounis TN, Chiladakis J, et al. Successful percutaneous extraction of pacemaker leads with a novel (VascoExtor) pacing lead removal system. Am J Cardiol 1998;81(7):935–938.
Alt E, Neuzner J, Binner L, et al. Three-year experience with a stylet for lead extraction: A multicenter study. PACE 1996;19:18–25.
Jordaens L, Van Belleghem Y, Herregods L. Removal of endocardial defibrillation leads. PACE 1996;19:127–129.
Samuels LE, Samuels FL, Kaufman MS, et al. Management of infected implantable cardiac defibrillators. Ann Thorac Surg 1997;64:1702–1706.
Niebauer M, Wilkoff B, Van Zandt H, et al. Nonthoracotomy defibrillator lead extraction: Comparison with ventricular pacing leads. PACE 1997;20(4):1071
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Vassilikos, V.P., Maounis, T.N., Chiladakis, J. et al. Percutaneous Extraction of Transvenous Defibrillator Leads Using the VascoExtor Pacing Lead Removal System. J Interv Card Electrophysiol 3, 247–251 (1999). https://doi.org/10.1023/A:1009899708781
Issue Date:
DOI: https://doi.org/10.1023/A:1009899708781