A Randomized Comparison of Fixed Power and Temperature Monitoring During Slow Pathway Ablation in Patients With Atrioventricular Nodal Reentrant Tachycardia

  • Published:
Journal of Interventional Cardiac Electrophysiology Aims and scope Submit manuscript

Abstract

Temperature monitoring may be helpful for ablation of accessory pathways, however its role in ablation of atrioventricular nodal reentrant tachycardia (AVNRT) using the slow pathway approach is unclear. Therefore, the purpose of this study was to prospectively compare slow pathway ablation for AVNRT using fixed power or temperature monitoring. The study included 120 patients undergoing ablation for AVNRT. Patients were randomly assigned to receive either fixed power at 32 watts, or to temperature monitoring with a target temperature of 60°C. The primary success rate was 72% in the fixed power group and 95% in the temperature monitoring group (p=0.001). The ablation procedure duration (35±29 min vs 35±30 min; p=0.9), fluoroscopic time (32±17 vs 35±19 min; p=0.4), mean number of applications (10.2±8.1 vs 8.4±7.9; p=0.2), and coagulum formation per application (0.2% vs 0.5%; p=0.6) were statistically similar in the fixed power and temperature monitoring groups, respectively. The mean temperature (47.3±4.8°C vs 48.6±3.8°C; p<0.01), and the temperature associated with junctional ectopy (48.2±3.8°C vs 49.3±3.6°C, p<0.01) were less for the fixed power than the temperature monitoring group. In the temperature monitoring group, only 31% of applications achieved an electrode temperature of 60°C. During follow up of 6.6±3.6 months there were two recurrences in the fixed power group and one in the temperature monitoring group (p=1.0). In summary, power titration directed by temperature monitoring was associated with an improved primary procedural success rate. Applications of energy were associated with a temperature of approximately 50°C with both techniques, suggesting that there is a low efficiency of heating in the posterior septum.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Langberg JJ, Calkins H, El-Atassi R, et al. Temperature monitoring during radiofrequency catheter ablation of accessory pathways. Circulation 1992;86(5):1469–74.

    Google Scholar 

  2. Nath S, DiMarco P, Mounsey P, Lobban JH, Haines DE. Correlation of temperature and pathophysiological effect during radiofrequency catheter ablation of the AV junction. Circulation 1995;92:1188–92.

    Google Scholar 

  3. Strickberger SA, Zivin A, Daoud EG, et al. Temperature and impedance monitoring during slow pathway ablation in patients with AV nodal reentrant tachycardia. J Cardiovasc Electrophysiol 1996;7:295–300.

    Google Scholar 

  4. Strickberger AS, Ravi S, Daoud E, et al. The relationship between impedance and temperature during radiofrequency ablation of accessory pathways. Am Heart J 1995;130: 1026–30.

    Google Scholar 

  5. Strickberger SA, Weiss R, Knight BP, et al. A randomized comparison of two techniques for titrating power during radiofrequency ablation of accessory pathways. JCE 1996;7: 795–801.

    Google Scholar 

  6. Josephson ME. Clinical Cardiac Electrophysiology: Techniques and Interpretations. Philadelphia: Lea & Febiger, 1993:181–224.

    Google Scholar 

  7. Kalbfleisch SJ, Strickberger SA, Williamson B, et al. Randomized comparison of anatomic and electrogram mapping approaches to ablation of the slow pathway of atrioventricular node reentrant tachycardia. J Am Coll Cardiol 1994;23:716–23.

    Google Scholar 

  8. Langberg JJ, Harvey M, Calkins H, El-Atassi R, Kalbfleisch SJ, Morady F. Titration of power output during radiofrequency catheter ablation of atrioventricular nodal reentrant tachycardia. PACE 1993;16:465–70.

    Google Scholar 

  9. Jentzer JH, Goyal R, Williamson BD, et al. Analysis of junctional ectopy during radiofrequency ablation of the slow pathway in patients with atrioventricular nodal reentrant tachycardia. Circulation 1994;90:2820–26.

    Google Scholar 

  10. Jackman WM, Beckman KJ, McClelland JH, et al. Treatment of supraventricular tachycardia due to atrioventricular nodal reentry by radiofrequency catheter ablation of slow-pathway conduction. N Engl J Med 1992;327:313–8.

    Google Scholar 

  11. Kay GN, Epstein AE, Dailey SM, Plumb VJ. Selective radiofrequency ablation of the slow pathway for the treatment of atrioventricular nodal reentrant tachycardia. Circulation 1992;85:1675–88.

    Google Scholar 

  12. Haissaguerre M, Gaita F, Fischer B, et al. Eliminating of atrioventricular nodal reentrant tachycardia using discrete slow potentials to guide application of radiofrequency energy. Circulation 1992;85:2162–75.

    Google Scholar 

  13. Jazayeri MR, Hempe SL, Sra JS, et al. Selective transcatheter ablation of the fast and slow pathways using radiofrequency energy in patients with atrioventricular nodal reentrant tachycardia. Circulation 1992;85:1318–28.

    Google Scholar 

  14. Wathen M, Natale A, Wolfe K, Yee R, Newman D, Klein F: An anatomically guided approach to atrioventricular node slow pathway ablation. Am J Cardiol 1992;70:886–9.

    Google Scholar 

  15. Calkins H, Sousa J, El-Atassi R, et al. Diagnosis and cure of Wolff-Parkinson-White syndrome or paroxysmal supraventricular tachycardia during a single electrophysiologic test. N Engl J Med 1991;324:1612–1618.

    Google Scholar 

  16. Calkins H, Prystowsky E, Carlson M, Klein LS, Saul JP, Gillette P. Temperature monitoring during radiofrequency catheter ablation procedures using closed loop control. Circulation 1994;90:1279–86.

    Google Scholar 

  17. Thakur RK, Klein GJ, Yee R, Stites HW. Junctional tachycardia: a useful marker during radiofrequency ablation for atrioventricular node reentrant tachycardia. J Am Coll Cardiol 1993;22:1706–10.

    Google Scholar 

  18. Strickberger SA, Hummel JD, Gallagher M, et al. The effect of accessory pathway location on the efficiency of heating during radiofrequency catheter ablation. Am Heart J 1995;129(1):54–8.

    Google Scholar 

  19. Choi YS, Sohn KS, Sohn DW, et al. Temperature-guided radiofrequency catheter ablation of slow pathway in atrioventricular nodal reentrant tachycardia. Am Heart J 1995;129(2):392–99.

    Google Scholar 

  20. Hindricks G, Haverkamp W, Gulker H, et al. Radiofrequency coagulation of ventricular myocardium: Improved prediction of lesion size by monitoring catheter tip temperature. Eur Heart J 1989;10:972–84.

    Google Scholar 

  21. Hindricks G, Haverkamp W, Gulker H, et al. Radiofrequency coagulation of ventricular myocardium: Improved prediction of lesion size by monitoring catheter tip temperature. Eur Heart J 1989;10:972–84.

    Google Scholar 

Download references

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Strickberger, S.A., Daoud, E.G., Weiss, R. et al. A Randomized Comparison of Fixed Power and Temperature Monitoring During Slow Pathway Ablation in Patients With Atrioventricular Nodal Reentrant Tachycardia. J Interv Card Electrophysiol 1, 299–303 (1997). https://doi.org/10.1023/A:1009733110281

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1023/A:1009733110281

Navigation