The in-vivo response to a composite material obtained with polyetherimide (PEI) reinforced with carbon/glass fibers was investigated by histological methods by implanting cylinders in muscle and in bone of the New Zealand White rabbit. A common metallic alloy, widely used in orthopaedic surgery, was used as control (Stellite). The aim of the study was to analyze the biological response towards the surface of the material. Composite implants and metallic implants did not induce adverse or inflammatory reactions. The morphological picture produced was similar, in muscle and in bone, for both materials. In muscle, cylinders were confined by an extremely thin fibrous layer and the overall appearance of the muscular tissue was normal. In bone, cylinders were confined by a nearly annular rim of newly formed bone. From these data it is possible to derive that the response to PEI-based composite material is comparable with the response to metallic substrate and, then, the material can be suitable for clinical application. ©1999 Kluwer Academic Publishers

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. L. M. Wenz, K. Merrit, S. A. Brown, A. Moet and A. D. Steffe, J. Biomed. Mater. Res. 24 (1990) 207.

    Google Scholar 

  2. G. Peluso, L. Ambrosio, M. Cinquegrani, L. Nicolais, S. Saiello and G. Tajana, Biomaterials 12 (1991) 231.

    Google Scholar 

  3. R. R. Richardson JR, J. A. Miller and W. M. Reichert, ibid. 14 (1993) 627.

    Google Scholar 

  4. H. S. Haggerty and H. S. Lusted, Acta Otolaryngol. 107 (1989) 13.

    Google Scholar 

  5. G. Peluso, O. Petillo, L. Ambrosio and L. Nicolais, J. Mater. Sci. Mater. Med. 5 (1994) 738.

    Google Scholar 

  6. O. Petillo, G. Peluso, L. Ambrosio, L. Nicolais, W. J. Kao and J. M. Anderson, J. Biomed. Mater. Res. 28(1994) 635.

    Google Scholar 

  7. P. Tranquilli leali, A. Merolli, O. Palmacci, C. Gabbi, A. Cacchioli and G. Gonizzi, J. Mater. Sci. Mater. Med. 5 (1994) 345.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Merolli, A., Perrone, V., Leali, P.T. et al. Response to polyetherimide based composite materials implanted in muscle and in bone. Journal of Materials Science: Materials in Medicine 10, 265–268 (1999). https://doi.org/10.1023/A:1008949311714

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1023/A:1008949311714

Keywords

Navigation