Abstract
A study was carried out to investigate changes in mechanical properties and degradation of self-reinforced fibrillated poly-96L/4D-lactide (SR-PLA96) rods in vitro and in vivo. The viscosity-average molecular weight, Mv, of the intact sterile (gamma irradiated) rods was around 50 000 g mol-1. The SR-PLA96 rods of diameter 1.1 mm by 30 mm and diameter 4.5 mm by 50 mm were immersed in phosphate-buffered saline or implanted in the dorsal subcutis of rabbits. Bending, shear and torsion strength and bending modulus, together with the changes of viscosity and crystallinity, were measured up to 24 wk. The strength values showed only a slight decrease during the follow-up period with the exception of torsion strength, that decreased to 52% of the initial value during 24 wk. There were no statistically significant differences in the strength retention between in vitro and in vivo groups. Crystallinity increased over time, being 46–49% at 24 wk. The Mv of the rods decreased over 50% by 24 wk. These promising results motivated us to continue the studies with the fixation of experimental cortical bone osteotomies with SR-PLA96 intramedullary rods. © 1999 Kluwer Academic Publishers
Similar content being viewed by others
References
S. VainionpÄÄ, P. Rokkanenand P. TÖrmÄlÄ, Prog. Polym. Sci. 14(1989) 679.
J. E. RÄihÄ, Clin. Mater. 10(1992) 35.
J. E. RÄiuphÄ, Thesis, College of Veterinary Medicine in Helsinki (1993).
H. PhilajamÄki, Thesis, University of Helsinki (1994).
O. Laitinen, Thesis, College of Veterinary Medicine in Helsinki (1994).
E. K. Partio, Thesis, University of Helsinki (1992).
R. W. Bucholtz, S. Henryand M. B. Henley, J. Bone Joint Surg. 76A(1994) 319.
P. TÖrmÄlÄ, P. Rokkanen, J. Laiho, M. TamminmÄki and S. VainionpÄÄ, US Pat. 4743 257 (1988).
P. TÖrmÄlÄ, P. Rokkanen, S. VainionpÄÄ, J. Laiho, V.-P. Heponenand T. Pohjonen, US Pat. 4968 317(1990).
A. Majola, S. VainionpÄÄ, K. Vihtonen, J. Vasenius, P. TÖrmÄlÄ and P. Rokkanen, Int. Orthopaed. 16(1992) 101.
M. J. Manninenand T. Pohjonen, Biomaterials 14 (1993) 305.
A. Majola, in “Self-Reinforced Bioabsorbable Polymeric Composites in Surgery”, edited by P. Rokkanen and P. Törmälä (Tampereen Pikakopio Oy, Tampere, 1995) p. 34.
J. E. Bergsma, W. C. Debruijn, F. R. Rozema, R. R. M. Bosand G. Boering, Biomaterials 16(1995) 25.
O. M. BÖstman, H. K. PihlajamÄki, E. K. Partio and P. U. Rokkanen, Clin. Orthop. 320(1995) 101.
P. Christel, M. Vert, F. Chabot, H. Garreauand M. Audion, in “Composites in biomedical engineering”, Plastic and Rubber Institute Proceedings (1985) pp. 11/1-11/10R.
Y. Matsusue, S. Hanafusa, T. Yamamuro, Y. Shikinamiand Y. Ikada, Clin. Orthop. Rel. Res. 317 (1995) 246.
O. M. BÖstman, J. Bone Joint Surg. 73-A (1991) 148.
J. O. Hollingerand G. C. Battistone, Clin. Orthop. 207(1986) 290.
M. Vert, S. Liand H. Garreau, Clin. Mater. 10(1992) 3.
X. Zhang, U. P. Wyss, D. Pichoraand M. F. A. Goosen, J. Bioact Comp. Polym. 9(1996) 80.
M. V. D. Elst, I. Kuiper, C. P. A. T. Klein, P. Patka and H. J. Th. M. Haarman, J. Biomed. Mater. Res. 30 (1996) 139.
R. K. Kulkarni, E. G. Moore, A. F. Hegyeliand F. Leonard, ibid. 5(1971) 169.
A. Majola, S. VainionpÄÄ, K. Vihtonen, M. Mero, J. Vasenius, P. TÖ rmÄlÄ and P. Rokkanen, Clin. Orthop. 268(1991) 260.
K. P. Andriano, T. Pohjonenand P. TÖ rmÄlÄ, J. Appl. Biomater. 5(1994) 133.
J. E. Bergsma, F. R. Rozema, R. R. M. Bos, G. Boering, W. C. De Bruijn and A. J. Pennings, Biomaterials 16(1995) 267.
J. J. Bergsma, F. R. Rozema, R. R. M. Bos, G. Boering, C. A. P. Joziasseand A. J. Pennings, J. Mater. Sci. Mater. Med. 6(1995) 642.
F. W. Cordewener, F. R. Rozema, R. R. Bosand G. Boering, ibid. 6(1995) 211.
P. TÖrmÄlÄ, Clin. Mater. 10(1992) 29.
BS 2782: Part 3: Methods 340A and 340B (British Standards Institution, London, 1978).
C. Migliaresi, D. Cohn, A. De Lollis and L. Fambri,J. Appl. Polym. Sci. 43(1991) 83.
E. W. Fischer, H. J. Sterzeland G. Wegner, Koll. Z. Z. Polym. 251(1973) 980.
H. Pistner, D. R. Bendix, J. Muhlingand J. F. Reuther, Biomaterials 14(1993) 291.
A. Schindlerand D. Harper, J. Polym. Sci. 17(1979) 2593.
A. Majola, S. VainionpÄÄ, H.H.-M. Mikkola, P. TÖrmÄlÄ and P. Rokkanen, J. Mater. Sci. Mater. Med. 3(1992) 43.
J. Vasenius, S. VainionpÄÄ, K. Vihtonen, A. MÄkelÄand P. Rokkanen, Biomaterials 11(1990) 501.
Y. Matsusue, T. Yamamuro, M. Oka, Y. Shikinami, S.-H. Hyonand Y. Ikada, J. Biomed. Mater. Res. 26(1992) 1553.
J. W. Leenslag, A. J. Pennings, R. R. M. Bosand F. R. Rozema, Biomaterials 8(1987) 311.
R. R. M. Bos, Thesis, University of Groningen (1989) p. 55.
R. Suuronen, T. Pohjonen, R. Taurio, P. TÖ rmÄlÄ, L. Wessman, K. RÖnkkÖ and S. VainionpÄÄ, J. Mater. Sci. Mater. Med. 3(1992) 426.
D. F. Williams, Eng. Med. 10(1981) 5.
S. Gogolewski, M. Jovanovic, S. M. Perren, J. G. Dillonand M. K. Hughes, J. Biomed. Mater. Res. 27 (1993) 1135.
S. A. V. Swanson, in “Advances in Biomedical Engineering” edited by R. M. Kenedi (Academic Press London, 1971) p. 138.
T. Pohjonen, Licenciate Thesis, Tampere University of Technology (1995).
A. M. Reedand D. K. Gilding, Polymer 22(1981) 494.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
SAIKKU-BÄCKSTRÖM, A., Tulamo, R.M., Pohjonen, T. et al. Material properties of a. Journal of Materials Science: Materials in Medicine 10, 1–8 (1999). https://doi.org/10.1023/A:1008828925090