Skip to main content
Log in

A Chip for an Implantable Neural Stimulator

  • Published:
Analog Integrated Circuits and Signal Processing Aims and scope Submit manuscript

Abstract

This paper describes a chip for a multichannel neural stimulator for functional electrical stimulation (FES). The purpose of FES is to restore muscular control in disabled patients. The chip performs all the signal processing required in an implanted neural stimulator. The power and digital data transmission to the stimulator passes through a 5 MHz inductive link. From the signals transmitted to the stimulator, the chip is able to generate charge-balanced current pulses with a controllable length up to 256 μs and an amplitude up to 2 mA, for stimulation of nerve fibers. The quiescent current consumption of the chip is approx. 650 μA at supply voltages of 6–12 V, and its size is 3.9×3.5 mm2. It has 4 output channels for use in a multipolar cuff electrode.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. G. E. Loeb, C. J. Zamin, J. H. Schulman, and P. A. Troyk, “Injectable stimulator for functional electrical stimulation.” Med. & Biol. Eng. & Comput. 29, pp. NS13–NS19, 1991.

    Google Scholar 

  2. M. Nardin and K. Najafi, “A multichannel neuromuscular microstimulator with bi-directional telemetry.” 1995 Int. Conf. on Solid-State Sensors and Actuators, Transducers '95 Stockholm, pp. 59–62, 1995.

  3. T. M. Cameron, G. E. Loeb, R. A. Peck, J. H. Schulman, P. Strojnik, and P. A. Troyk, “Micromodular implants to provide electrical stimulation of paralyzed muscles and limbs.” IEEE Trans. Biomed. Eng. BME-44, pp. 781–790, 1997.

    Google Scholar 

  4. B. Ziaie, M. Nardin, A. R. Coghlan, and K. Najafi, “A singlechannel implantable microstimulator for functional neuromuscular stimulation.” IEEE Trans. Biomed. Eng. BME-44, pp. 909–920, 1997.

    Google Scholar 

  5. B. Smith et al., “An externally powered, multichannel, implantable stimulator-telemeter for control of paralyzed muscle.” IEEE Trans. Biomed. Eng. BME-45, pp. 463–475, 1998.

    Google Scholar 

  6. C. Kim and K. D. Wise, “A 64-site multishank CMOS lowprofile neural stimulating probe.” IEEE J. Solid-State Circuits SC-31, pp. 1230–1238, 1996.

    Google Scholar 

  7. K. E. Jones and R. A. Normann, “An advanced demultiplexing system for physiological stimulation.” IEEE Trans. Biomed. Eng. BME-44, pp. 1210–1220, 1997.

    Google Scholar 

  8. Z. Tang and P. H. Peckham, “Multichannel implantable stimulation and telemetry system for neuromuscular control.” Proc. 16th Annual Int. Conf. of the IEEE Eng. in Medicine and Biology Soc. 1, pp. 442–443, 1994.

    Google Scholar 

  9. G. E. Loeb and R. A. Peck, “Cuff electrodes for chronic stimulation and recording of peripheral nerve activity.” J. of Neurosci. Methods 64, pp. 95–103, 1996.

    Google Scholar 

  10. C. Veraart, W. Grill, and J. T. Mortimer, “Selective control of muscle activation with a multipolar nerve cuff electrode.” IEEE Trans. Biomed. Eng. BME-40, pp. 640–653, 1993.

    Google Scholar 

  11. Floyd M. Gardner, “Charge-pump phase-locked loops.” IEEE Trans. Comm. COM-28, pp. 1849–1858, 1980.

    Google Scholar 

  12. B. Keeth, R. J. Baker, and H. W. Li, “CMOS transconductor VCO with adjustable operating and center frequencies.” Electronics Letters 31, pp. 1397, 1995.

    Google Scholar 

  13. Gunnar Gudnason, An Implantable Multichannel Neural Stimulator for Functional Electrical Stimulation. M.Sc. thesis, Department of Information Technology, Technical University of Denmark, 1997.

  14. N. de N. Donaldson and P. E. K. Donaldson, “When are actively balanced biphasic (`Lilly') stimulating pulses necessary in a neurological prosthesis?” Med. & Biol. Eng. & Comput. 24, pp. 41–56, 1986.

    Google Scholar 

  15. T. L. Rose and L. S. Robblee, “Electrical stimulation with Pt electrodes. VIII. Electrochemically safe charge injection limits with 0.2 ms pulses.” IEEE Trans. Biomed. Eng. BME-37, pp. 1118–1120, 1990.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Gudnason, G., Bruun, E. & Haugland, M. A Chip for an Implantable Neural Stimulator. Analog Integrated Circuits and Signal Processing 22, 81–89 (2000). https://doi.org/10.1023/A:1008328228307

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1023/A:1008328228307

Navigation