Skip to main content

A decade of experience with TCu200

Abstract

This paper summarizes ten years of experience with 2766 interval insertions of the TCu200 device. One hundred and twenty months of use were completed by 572 patients and the cumulative woman-months of use were 159 664. For evaluating the overall performance, gross cumulative and yearly specific life-table termination and continuation rates were calculated as suggested by Tietze [2]. The cumulative pertinent rates at the end of the ten-year follow-up period were as follows: pregnancy 10.2; expulsion 6.3; bleeding/pain 32.3; and removal for other medical reasons 19.4. The gross annual rates for the same conditions at the end of the first year of use were: 1.8, 2.4, 4.2, and 2.0, while in the tenth year they were: 0.6, 0.1, 4.4, and 2.8, respectively. The continuation rate was 89.1 at the end of the 12th month and 33.2 at the end of the 10th year. Based on this evaluation, the TCu200 IUD has a good overall performance and a longer lifespan than was previously expected.

This is a preview of subscription content, access via your institution.

References

  1. Zipper JA, Tatum HJ, Pastene L, Medel M, Rivera M. Metallic copper as an intrauterine contraceptive adjunct to the “T” device. Am J Obstet Gynecol. 1969;105(8):1274-8.

    Google Scholar 

  2. Tietze C, Lewit S. Recommended procedures for statistical evaluation of intrauterine contraception. Stud Fam Plann. 1973;4(2):35-42.

    Google Scholar 

  3. Tietze C. Evaluation of intrauterine devices: ninth progress report of the Cooperative Statistical Program. Stud Fam Plann. 1970;55(1):1-40.

    Google Scholar 

  4. Batar I. MLCu250 IUD: A decade of experience. Adv Contracept. 1988;4:271-9.

    Google Scholar 

  5. Randic L, Haller H, Perovic M, Farr G. The effect of adding copper onto Lippes Loop IUDs: results from a ten-year study in Yugoslavia. Contraception. 1991;43(3):229-39.

    Google Scholar 

  6. Diaz J, Bahamondes L, Diaz M, Marchi N, Faundes A, Marini M. Evaluation of the copper T380A IUD up to ten years. Is this IUD a reversible but potentially permanent method? Adv Contracept. 1992;8:275-80.

    Google Scholar 

  7. Theiry M, Van Der Pas H, Van Kets H. A decade of experience with the TCu220C. Adv Contracept. 1985;1:313-18.

    Google Scholar 

  8. Rowe PJ. Research on intrauterine devices. In: World Health Organization (WHO). Special Program of Research, Development and Research Training in Human Reproduction. Annual Technical Report: 1992. Geneva: WHO, 1993:289.

    Google Scholar 

  9. Vessey M, Doll R, Peto R, Johnson B, Wiggins P. A long-term follow-up study of women using different methods of contraception — an interim report. J Biosoc Sci. 1976;8(4):373-427.

    Google Scholar 

  10. Bernard RP. Factors governing IUD performance. Am J Public Health. 1971;61:559.

    Google Scholar 

  11. Treiman K, Liskin L, Kols A, Rinehart W. IUDs — An Update. Population Reports. Series B, No. 6. 1995. The Johns Hopkins School of Public Health, Baltimore.

    Google Scholar 

Download references

Author information

Affiliations

Authors

Rights and permissions

Reprints and Permissions

About this article

Cite this article

Bhattoa, H., Ganacharya, S. & Batár, I. A decade of experience with TCu200. Advances in Contraception 15, 351–361 (1999). https://doi.org/10.1023/A:1006708911895

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1023/A:1006708911895

Keywords

  • Public Health
  • Annual Rate
  • Medical Reason
  • Continuation Rate
  • Longe Lifespan