Abstract
The dispersion of pollutants from naturally ventilated underground parking garages has been studied in a boundary layer wind tunnel. Two idealized model setups have been analysed, one was simulating pollutant dispersion around an isolated rectangular building and one was representing dispersion in a finite array of idealized building blocks. Flow and dispersion close to modelled ground level emission sources was measured. The results illustrate the complexity of the flow around buildings and provide insight in pollutant transport from ground level sources located directly on building surfaces. As a result, areas critical with respect to high pollutant concentrations could be visualized. Particularly, the results show high concentration gradients on the surface of the buildings equipped with modelled emission sources. Inside the boundary layers on the building walls, a significant amount of pollutants is transported to upwind locations on the surface of the building. The paper documents the potential of physical modelling to be used for the simulation and measurement of dispersion close to emission sources and within complex building arrangements.
Similar content being viewed by others
References
B.A.U.CH.: 1993, Sachbericht zum Projekt “Belastung der Innenraumluft durch Emissionen aus Tiefgaragen, Beratung und Analyse-Verein für Umweltchemie e.V., Wilsnacker Str. 15, D-10559 Berlin, p. 47
Environ Corporation: 1984, Sensitivity Analysis of the California Department of Health Services Risk Assessment of Benzene, Prepared for the American Petroleum Institute, Washington
ARC MONOGRAPHS: 1982, Benzene and Annex. In: Some industrial chemicals and dyestuffs. Lyon, International Agency for Research on Cancer, IARC Monographs on the Evaluation of the Carcinogenic Risk of Chemicals to Humans, Vol. 29
Kaimal, J.C., Wyngaard, J.C., Izumi, Y., Cote, O.R.: 1971, Spectral characteristic of surface layer turbulence, Quart. J. Roy. Meteorol. Soc., Vol. 98, No. 417, pp. 563–589
Simiu, E., Scanlan, R. H.: 1986, Wind Effects on Structures-Part A: The Atmosphere, John Wiley &; Sons, Inc.
TÑV Nord e.V.: 1996, Studie-Anforderungen an die Lüftung von Tiefgaragen unter dem Gesichtspunkt von Schadstoffimmissionen, Technischer Ñberwachungs-Verein Nord e.V., Große Bahnstraße 31, D-22525 Hamburg, p.70
VDI 3783: 1999, Physical modelling of flow and dispersion processes in the atmospheric boundary layer, VDI, Environmental Meteorology, VDI/DIN Manual of the Commission on Air Pollution Prevention, VDI 3783-12 (Draft), p.22
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Leitl, B., Schatzmann, M. Physical Modeling of Emissions from Naturally Ventilated Underground Parking Garages. Environ Monit Assess 65, 221–229 (2000). https://doi.org/10.1023/A:1006408411557
Issue Date:
DOI: https://doi.org/10.1023/A:1006408411557