Local Air Quality Impacts due to Downwash Around Thermal Power Plants: Numerical Simulations of the Effect of Building Orientation

  • Published:
Environmental Monitoring and Assessment Aims and scope Submit manuscript

Abstract

One of the primary adverse environmental impacts associated with power generation facilities and in particular thermal power plants is local air quality. When these plants are operated at inland areas the dry type cooling towers used may significantly increase ambient concentrations of air pollutants due to the building downwash effect. When one or more buildings in the vicinity of a point source interrupt wind flow, an area of turbulence known as a building wake is created. Pollutants emitted from relatively low level sources can be caught in this turbulence affecting their dispersion. In spite of the fact that natural gas-fired combined-cycle power plants have lower air emission levels compared to other power plants using alternative fossil fuel, they can still create significant local air pollution problems. In this paper, local air quality impacts of a natural gas-fired combined-cycle power plant located in a coastal area are compared with those of another natural gas-fired combined-cycle power plant having identical air emissions but located in an inland area taking into account differences in topography and meteorology. Additionally, a series of scenarios for the inland site have been envisaged to illustrate the importance of plant lay-out configurations paying particular attention to the building downwash effect. Model results showed that different geometrical configurations of the stacks and cooling towers will cause remarkable differences in ambient air pollutant concentrations; thus it is concluded that when selecting a plant site, a detailed site-specific investigation should be conducted in order to achieve the least possible ambient air pollution concentrations with the given emissions.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Baumann, E. R. and Dehart, R. K.: 1988, ‘Evaluation and Assessment of UNAMAP', EPA/600/3–88/009, U.S. Environmental Protection Agency, Research Triangle Park, North Carolina 27711.

    Google Scholar 

  • Bowers, J. F., Bjorkland, J. R. and Cheney, C. S.: 1979, ‘Industrial Source Complex (ISC) Dispersion Model User's Guide', Volume I, EPA-450/4–79–030, U.S. Environmental Protection Agency, Research Triangle Park, North Carolina 27711.

    Google Scholar 

  • Bowers, J. F. and Anderson, A. J.: 1981, ‘An Evaluation Study for the Industrial Source Complex (ISC) Dispersion Model', EPA-450/4–81–002, U.S. Environmental Protection Agency, Research Triangle Park, North Carolina 27711.

    Google Scholar 

  • Bowers, J. F., Anderson, A. J. and Hargraves, W. R.: 1982, ‘Tests of the Industrial Source Complex (ISC) Dispersion Model at the Armco, Middletown, Ohio Steel Mill', EPA-450/4–82–006, U.S. Environmental Protection Agency, Research Triangle Park, North Carolina 27711.

    Google Scholar 

  • Çakiroğlu, C. and Yurteri, C.: 1998, ‘Methodology for Predicting the CoolingWater Effects on Fish', Journal of Env. Eng. (in press).

  • Huber, A. H.: 1977, ‘Incorporating Building/Terrain Wake Effects on Stack Effluents', in Preprint Volume for the Joint Conference on Applications of Air Pollution Meteorology, American Meteorological Society, Boston, Massachusetts.

    Google Scholar 

  • Huber, A. H. and Synder, W. H.: 1976, ‘Building Wake Effects on Short Stack Effluents', in Preprint Volume for the Third Symposium on Atmospheric Diffusion and Air Quality, American Meteorological Society, Boston, Massachusetts.

    Google Scholar 

  • Huber, A. H. and Synder, W. H.: 1982, ‘Wind tunnel investigation of the effects of a rectangularshaped building on dispersion of effluents from short adjacent stacks', Atmospheric Environment 176, 2837–2848.

    Google Scholar 

  • Kayin, S., Önder, K., Tokinan, N., Tuncel, G. and Yurteri, C.: 1995, ‘Comparison of Environmental Impacts of Natural Gas-Fired Combined Cycle Power Plants with Different Cooling Systems', in Proceedings of International Symposium on Efficiency, Costs, Optimization, Simulation and Environmental Impact of Energy Systems (ECOS'95), 769–775, Istanbul.

  • Kuntasal, G. and Kayin, S.: 1995, ‘Regulatory Air Quality Modelling', in Proceedings of International Symposium on Coal-Fired Power Generation, the Environment and Public Acceptance, 143–152, Ankara.

  • Rorex, H. W.: 1990, ‘Operational Review of the Support Center for Regulatory Air Models Bulletin Board Service', U.S. Environmental Protection Agency, Research Triangle Park, North Carolina 27711.

    Google Scholar 

  • REG-308: 1990, ‘MET Pre-Processor', Ontario Ministry of Environment, Toronto, 1990.

  • Schulman, L. L. and Hanna, S. R.: 1986, ‘Evaluation of downwash modifications to the Industrial Source Complex Model', J. of Air Poll. Control Assoc. 36(3), 258–264.

    Google Scholar 

  • Schulman, L. L., Hanna, S. R. and Heinhold, D. W.: 1985, ‘Evaluation of proposed downwash modifications to the Industrial Source Complex Model', Environmental Research and Technology, Inc., P-B810–012, January.

  • Scire, J. S. and Schulman, L. L.: 1980, ‘Modelling plume rise from low-level buoyant line and point sources', in Proceedings Second Joint Conference on Applications of Air Pollution Meteorology, 24–28 March, New Orleans, LA. 133–139.

  • Touma, J. S., Irwin, J. S., Tikvart, J. A. and Coulter, C. T.: 1995, ‘A Review of Procedures for Updating Air Quality Modeling Techniques for Regulatory Modeling Programs', J. App. Meteor. 34, 731–737.

    Google Scholar 

  • U.S. Environmental Protection Agency: 1986, ‘Guideline for Determination of Good Engineering Practice Stack Height (Technical Support Document for the Stack Height Regulations) - Revised', EPA-450/4–80–023R, U.S. Environmental Protection Agency, Research Triangle Park, North Carolina 27771.

    Google Scholar 

  • U.S. Environmental Protection Agency: 1987a, ‘Industrial Source Complex (ISC) Dispersion Model User's Guide? - Second Edition (Revised)', Volume I. EPA-450/4–88–002a, U.S. Environmental Protection Agency, Research Triangle Park, North Carolina 27771.

    Google Scholar 

  • U.S. Environmental Protection Agency: 1987b, ‘Guideline on Air Quality Models (Revised) and Supplement A', EPA-450/2–78–027R, U.S. Environmental Protection Agency, Research Triangle Park, North Carolina 27771.

    Google Scholar 

  • U.S. Environmental Protection Agency: 1992, ‘User's Guide for the Industrial Source Complex (ISC2) Dispersion Models, Volume I - User Instructions', EPA-450–4–92–008a, U.S. Environmental Protection Agency, Research Triangle Park, North Carolina 27771.

    Google Scholar 

  • U.S. Environmental Protection Agency: 1995, ‘User's Guide for the Industrial Source Complex (ISC3) Dispersion Models, Volume I - User Instructions', EPA-45/B-95–003a, U.S. Environmental Protection Agency, Research Triangle Park, North Carolina 27771.

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Kayin, S., Tuncel, G. & Yurteri, C. Local Air Quality Impacts due to Downwash Around Thermal Power Plants: Numerical Simulations of the Effect of Building Orientation. Environ Monit Assess 58, 61–77 (1999). https://doi.org/10.1023/A:1006091213463

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1023/A:1006091213463

Navigation