Skip to main content
Log in

Analysis of Pesticides Using a Polyppyrole Modified Electrode

  • Published:
Environmental Monitoring and Assessment Aims and scope Submit manuscript

Abstract

Electrochemical methods can provide fast, sensitive and sometimes real time detection of pesticides. In the course of this work, a dispersed mercury electrode has been used to detect pesticides electrochemically. The electrode was prepared by depositing a thin mercury film on a glassy carbon disc and then coating a layer of polypyrrole on the disc. The effect of coating thickness on detection sensitivity was studied. A thin mercury film of 0.34 µm dispersed by one cycle polymerization of pyrrole was preferred. The influence of electrolyte, pH and organic solvent content on pesticide response was also investigated. The polypyrrole dispersed mercury electrode (Hg-PPy/GC) was not suitable for a pH above 6 but it can tolerate acetonitrile up to 10% at which concentration the mercury film coated glassy carbon electrode (Hg/GC) failed to response. Methyl parathion, methyl azinphos, parathion and fenitrothion were detected. The sensitivity of the dispersed mercury electrode was similar to a normal thin mercury film electrode in this case. A good response can be obtained for 1 ppm pesticides using fast linear sweeping voltammetry.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

REFERENCES

  • Bourque, C. L., Duguay, M. M. and Gautreau, E. M.: 1989, Intern. J. Environ. Anal. Chem. 37, 187.

    Google Scholar 

  • Budnikov, H. C., Medyantseva, E. P. and Babkina, S. S.: 1991, J. Electroanal. Chem. 310, 49.

    Google Scholar 

  • Clath, G. S., Goodin, R. R. and Smiley, J. W.: 1985, Anal. Chem. 57, 2223.

    Google Scholar 

  • Don, X. D., and Krull, I. S.: 1984, J. Agril. Food Chem. 32, 622.

    Google Scholar 

  • Garguilo, M. G., Huynh, N., Proctor, A. and Michael, A. C.: 1993, Anal. Chem. 65, 523.

    Google Scholar 

  • Ge, H. and Lin, Y.: 1994, Sensors and Actuators B 21, 57.

    Google Scholar 

  • Ge, H., Zhao, H. and Wallace, G. G.: 1990, Anal. Chim. Acta 238, 345.

    Google Scholar 

  • Kumaran, S. and Tran-Minh, C.: 1992, Anal. Biochem. 200, 187.

    Google Scholar 

  • Lippolis, M. L. and Concialini, V.: 1988, Talanta 35, 235.

    Google Scholar 

  • Mendez, J. H., Martinez, R. C. and Jimenez, J. C.: 1988, Anal. Chim. Acta. 209, 205.

    Google Scholar 

  • Mendez, J. H., Martinez, R. C. and J. Sanchez Martin, J. S.: 1988, Anal. Chem. 58, 1969.

    Google Scholar 

  • Sherma, J.: 1993, Anal. Chem. 65, 4012.

    Google Scholar 

  • Skladal, P. and Mascini, M.: 1992, Biosensors and Bioelectronics 7, 335.

    Google Scholar 

  • Smyth, M. R. and Osteryoung, J. G.: 1978, Anal. Chim. Acta 96, 335.

    Google Scholar 

  • Smyth, M. R. and Smyth, W. F.: 1978, The Analyst 103, 529.

    Google Scholar 

  • Tamiya, E., Sugiura, Y., Navera, E. N., Mizoshita, S., Nakajima, K., Akiyama, A. and Karube, I.: 1991, Anal. Chim. Acta 251,129.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Hailin, G., Lye Ho, O. & Xinhao, Y. Analysis of Pesticides Using a Polyppyrole Modified Electrode. Environ Monit Assess 44, 361–367 (1997). https://doi.org/10.1023/A:1005799816175

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1023/A:1005799816175

Keywords

Navigation