Skip to main content
Log in

Improved assessment of intravascular Doppler coronary flow velocity profile

  • Published:
The International Journal of Cardiac Imaging Aims and scope Submit manuscript

Abstract

Easy and safe in- vivo flow velocity studies in small coronary arteries have become feasible using a 0.014 ‘ or 0.018 ’ guidewire with an integrated Doppler probe in its tip (FloWire, Cardiometrics). Assessment of the flow velocity profile by the ratio of diastolic to systolic flow velocity (DSVR) is used as a diagnostic parameter. However, DSVR is a coarse quantifier of the flow velocity profile, and is subject to large physiologic variance and depends crucially on the quality of the Doppler signal. The aim of our study was to test parameters derived from statistical time series analysis for monitoring the quality of the instantaneous peak velocity (IPV) signal. Improvement of quantification of changes in quality and shape of flow velocity profiles by these parameters as compared to DSVR was a second goal.

We investigated analog-digital converted IPV- signals and video registrations of corresponding greyscale spectra of intracoronary Doppler flow velocity signals. The signals were analyzed by using the autocorrelation function (ACF) in the time domain and a fast Fourier transform (FFT) in the frequency domain (standard time series statistics). The first minimum of autocorrelation function turned out to be very sensitive to signal quality, and Fisher's g of the periodogram was the parameter of choice for shape analysis. In 11 patients with coronary artery disease, pre and post PTCA, the sensitivity of DSVR and signal to noise ratio to changes in shape and quality of the flow velocity signals was compared to that of the new parameters. Nineteen Doppler flow velocity samples of good quality from measurements in nonstenotic vessels and 7 flow velocity tracings with visible artefacts were used to assess the value of these parameters in monitoring signal quality.

By comparison with corresponding parameters in use (SNR and DSVR) a significantly improved performance of the new statistical parameters was observed with respect to sensitivity to changes in signal quality and flow profile. In view of these results and because of the short calculation time of these variables they should be used for on-line quality control and analysis of flow velocity profiles.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Doucette JW, Corl DP, Payne HM, Flynn AE, Goto M, Nassi M et al. Validation of a Doppler guide wire for intravascular measurement of coronary artery flow velocity. Circulation 1992; 85: 1899-1911.

    Google Scholar 

  2. Kern MJ, Aguirre FV, Bach RG, Caracciolo EA Donohue TJ. Translesional pressure-flow velocity. Assessment in patients: Part I. Cath. Cardiovasc. Diag. 1994; 31: 49-60.

    Google Scholar 

  3. Segal J, Kern MJ, Scott NA, King III SB, Doucette JW, Heuser RR et al. Alterations of phasic coronary artery flow velocity in humans during percutaneous coronary angioplasty. J Am Coll Cardiol. 1992 Aug; 20(2): 276-286.

    Google Scholar 

  4. Ofili EO, Kern MJ, Labovitz AJ, St. Vrain JA, Segal J, Aguirre FV et al. Analysis of coronary blood flow velocity dynamics in angiographically normal and stenosed arteries before and after endoluminal enlargement by angioplasty. J Am Coll Cardiol 1993 Feb; 21(2): 308-316.

    Google Scholar 

  5. Sunamura M. di Mario C, Piek J, Schroeder E, Vrints C, Probst P, Heyndrickx G, Hanet C, Fleck E, Erbel R, Verna E, Voudris V, Geschwind H, Mühlberger V, Emanuelsson H, Campolo L, Peels HO, Ford AJ, Van Es GE Gil R, Montauban van Swijndregt E, Serruys PW, from the DEBATE Study Group. I. C. Doppler: Guidance during angioplasty. The Doppler Endpoints Balloon Angioplasty Trial Europe (DEBATE) study: Results of the second interim analysis. 6th Coronary Symposium QCA on Quantitative Coronary Imaging 1995.

  6. Brockwell PJ, Davis RA. Time series: Theory and methods. 2nd rev ed. New York: Springer-Verlag. 1991.

    Google Scholar 

  7. Armitage P, Berry G. Statistical methods in medical research. 2nd revised ed. Oxford: Blackwell Scientific Publications. 1987.

    Google Scholar 

  8. Yognathan AP, Cape EG, Sung HW, Williams FP, Jimoh A. Review of hydrodynamic principles for the cardiologist: applications to the study of blood flow and jets by imaging techniques. J Am Coll Cardiol 1988 Nov.; 12(5): 1344-1353.

    Google Scholar 

  9. Anderson HV, Kirkeeide RL, Stuart Y, Smalling RW, Heibig J, Willerson JT. Coronary artery flow monitoring following coronary interventions. Am J Cardiol 1993 May; 71(14): 62D-69D.

    Google Scholar 

  10. Kern MJ, Anderson HV. A symposium: the clinical applications of the intracoronary Doppler guidewire flow velocity in patients: understanding blood flow beyond coronary stenosis. Am J Cardiol 1993 May; 71(14): 1D-86D.

    Google Scholar 

  11. Sudhir K, MacGregor JS, Barbant SD, Foster E, Fitzgerald PJ, Chatterjee K, Yock PG. Assessment of coronary conductance and resistance vessel reactivity in response to nitroglycerin, ergonovine and adenosine: in vivo studies with simultaneous intravascular two-dimensional and Doppler ultrasound. J Am Coll Cardiol 1993 April.; 21(5): 1261-1268.

    Google Scholar 

  12. De Bruyne B, Vantrimpont P, Stockbroeks J, Demmor D, Heyndricks GR. Influence of a PTCA wire on stenosis dynamics. Circulation 1992; 86: I-855.

    Google Scholar 

  13. Di Mario C. Intracoronary ultrasound, (dissertation). Erasmus University of Rotterdam, 1993 (Part III: Intracoronary Doppler, 105–246).

  14. Roth T, Erbel R, Brennecke R, rupprecht HJ, Meyer J, v.Seelen W. Variations in accoustical beam properties of intracoronary Doppler catheters. Cath. Cardiovasc. Diag. 1993; 30: 257-263.

    Google Scholar 

  15. Baumgartner H, Schima H, Tulzer G, Kühn P. Effect of stenosis geometry on the Doppler-catheter gradient relation in vitro: A manifestation of pressure recovery. J Am Coll Cardiol 1993 März.; 21(4): 1018-1025.

    Google Scholar 

  16. Kajiya F. Characteristics and possible origins of blood velocity waveforms of epicardial and intramyocardial coronary circulation in the ventricles and the atria. In: Nakamura M, Vanhoutte PM, editors. Coronary circulation in physiological and pathophysiological states. Tokyo: Springer, 1991: 1-27.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Wellnhofer, E., Finke, W., Bernard, L. et al. Improved assessment of intravascular Doppler coronary flow velocity profile. Int J Cardiovasc Imaging 13, 25–34 (1997). https://doi.org/10.1023/A:1005714629995

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1023/A:1005714629995

Navigation