Skip to main content
Log in

Living with a Large Reduction in Permited Loading by Using a Hydrograph-Controlled Release Scheme

  • Published:
Environmental Monitoring and Assessment Aims and scope Submit manuscript

Abstract

The Total Maximum Daily Load (TMDL) for ammonia and biochemical oxygen demand for the Pee Dee, Waccamaw, and Atlantic Intracoastal Waterway system near Myrtle Beach, South Carolina, mandated a 60-percent reduction in point-source loading. For waters with a naturally low background dissolved-oxygen concentrations, South Carolina anti-degradation rules in the water-quality regulations allows a permitted discharger a reduction of dissolved oxygen of 0.1 milligrams per liter (mg/L). This is known as the “0.1 rule.” Permitted dischargers within this region of the State operate under the “0.1 rule” and cannot cause a cumulative impact greater than 0.1 mg/L on dissolved-oxygen concentrations. For municipal water-reclamation facilities to serve the rapidly growing resort and retirement community near Myrtle Beach, a variable loading scheme was developed to allow dischargers to utilize increased assimilative capacity during higher streamflow conditions while still meeting the requirements of a recently established TMDL.

As part of the TMDL development, an extensive real-time data-collection network was established in the lower Waccamaw and Pee Dee River watershed where continuous measurements of streamflow, water level, dissolved oxygen, temperature, and specific conductance are collected. In addition, the dynamic BRANCH/BLTM models were calibrated and validated to simulate the water quality and tidal dynamics of the system. The assimilative capacities for various streamflows were also analyzed.

The variable-loading scheme established total loadings for three streamflow levels. Model simulations show the results from the additional loading to be less than a 0.1mg/L reduction in dissolved oxygen. As part of the loading scheme, the real-time network was redesigned to monitor streamflow entering the study area and water-quality conditions in the location of dissolved-oxygen “sags.” The study reveals how one group of permit holders used a variable-loading scheme to implement restrictive permit limits without experiencing prohibitive capital expenditures or initiating a lengthy appeals process.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Carswell, W.J., Sanders, C.L., and Johnson, D.M.: 1988, Freshwater supply potential of the Atlantic Intracoastal Waterway near Myrtle Beach, South Carolina: U.S. Geological Survey Water-Resources Investigations Report 88-4066, 45 pp.

  • Drewes, P.A., and Conrads, P.A.: 1995, Assimilative capacity of the Waccamaw River and the Atlantic Intracoastal Waterway near Myrtle Beach, South Carolina, 1989-92: U.S. Geological Survey Water-Resources Investigations Report 95-4111, 58 pp.

  • Jobson, H.E.: 1997, Enhancements to the Branched Lagrangian Transport Modeling System: U.S. Geological Survey Water-Resources Investigation Report 97-4050, 56 pp.

  • Jobson, H.E., and Schoelhamer, D.H.: 1987, Users manual for a Branched Lagrangian Transport Model: U.S. Geological Survey Water-Resources Investigation Report 87-4163, 73 pp.

  • National Oceanic and Atmospheric Administration: 1995, Tide tables 1995, high and low predictions-East Coast of North and South America, Including Greenland: U.S. Department of Commerce, National Ocean Service, 301 pp.

  • Schaffranek, R.W., Baltzer, R.A. and Goldberg, D.E.: 1981, A model for simulation of flow in singular and interconnected channels: U.S. Geological Survey Techniques of Water-Resource Investigation, book 7, chap. C3, 100 pp.

  • South Carolina Department of Health and Environmental Control: 1991, Agreement on the development of wasteload allocations/total maximum daily loads and NPDES permit limitations, 43 pp.

  • — 1993, Water classifications and standards (Reg. 61-68) and classified waters (Reg. 61-69) for the State of South Carolina, 36 pp.

  • — 1999, Total Maximum Daily Load Determination for the Waccamaw River and the Atlantic Intracoastal Water Way Near Myrtle Beach, SC., 80 pp.

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Conrads, P.A., Martello, W.P. & Sullins, N.R. Living with a Large Reduction in Permited Loading by Using a Hydrograph-Controlled Release Scheme. Environ Monit Assess 81, 97–106 (2003). https://doi.org/10.1023/A:1021316705843

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1023/A:1021316705843

Navigation